951 resultados para Dyes in medical diagnosis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes some aspects of a computer system for doing medical diagnosis in the specialized field of kidney disease. Because such a system faces the spectre of combinatorial explosion, this discussion concentrates on heuristics which control the number of concurrent hypotheses and efficient "compiled" representations of medical knowledge. In particular, the differential diagnosis of hematuria (blood in the urine) is discussed in detail. A protocol of a simulated doctor/patient interaction is presented and analyzed to determine the crucial structures and processes involved in the diagnosis procedure. The data structure proposed for representing medical information revolves around elementary hypotheses which are activated when certain disposing of findings, activating hypotheses, evaluating hypotheses locally and combining hypotheses globally is examined for its heuristic implications. The thesis attempts to fit the problem of medical diagnosis into the framework of other Artifcial Intelligence problems and paradigms and in particular explores the notions of pure search vs. heuristic methods, linearity and interaction, local vs. global knowledge and the structure of hypotheses within the world of kidney disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Chapter 10, Adam and Dougherty describe the application of medical image processing to the assessment and treatment of spinal deformity, with a focus on the surgical treatment of idiopathic scoliosis. The natural history of spinal deformity and current approaches to surgical and non-surgical treatment are briefly described, followed by an overview of current clinically used imaging modalities. The key metrics currently used to assess the severity and progression of spinal deformities from medical images are presented, followed by a discussion of the errors and uncertainties involved in manual measurements. This provides the context for an analysis of automated and semi-automated image processing approaches to measure spinal curve shape and severity in two and three dimensions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enterprise architecture (EA) is a tool that aligns organization’s business-process with application and information technology (IT) through EAmodels. This EA model allows the organization to cut off unnecessary IT expenses and determines the future and current IT requirements and boosts organizational performance. Enterprise architecture may be employed in every firm where the firm or organization requires configurations between information technology and business functions. This research investigates the role of enterprise architecture in healthcare organizations and suggests the suitable EA framework for knowledge-based medical diagnostic system for EA modeling by comparing the two most widely used EA frameworks. The results of the comparison identified that the proposed EA has a better framework for knowledge-based medical diagnostic system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acetylcholine receptor (AchR) antibody assay has a key role in the diagnosis of myasthenia gravis. In this article, the role of AchR antibody assay in the diagnosis of ocular and generalized myasthenia gravis is reviewed, and compared to standard means of diagnosing the disease by clinical and electrophysiological methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Oropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. Methods We plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of ‘CFE + CA’ versus ‘CFE’ only compared to MBS-identified OPA. Discussion Early detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Concentrations of troponin measured with high sensitivity troponin assays are raised in a number of emergency department (ED) patients; however many are not diagnosed with acute myocardial infarction (AMI). Clinical comparisons between the early use (2 h after presentation) of high sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) assays for the diagnosis of AMI have not been reported. Design and methods: Early (0 h and 2 h) hs-cTnT and hs-cTnI assay results in 1571 ED patients with potential acute coronary syndrome (ACS) without ST elevation on electrocardiograph (ECG) were evaluated. The primary outcome was diagnosis of index MI adjudicated by cardiologists using the local cTnI assay results taken ≥6 h after presentation, ECGs and clinical information. Stored samples were later analysed with hs-cTnT and hs-cTnI assays. Results: The ROC analysis for AMI (204 patients; 13.0%) for hs-cTnT and hs-cTnI after 2 h was 0.95 (95% CI: 0.94–0.97) and 0.98 (95% CI: 0.97–0.99) respectively. The sensitivity, specificity, PLR, and NLR of hs-cTnT and hs-cTnI for AMI after 2 h were 94.1% (95% CI: 90.0–96.6) and 95.6% (95% CI: 91.8–97.7), 79.0% (95% CI: 76.8–81.1) and 92.5% (95% CI: 90.9–93.7), 4.48 (95% CI: 4.02–5.00) and 12.86 (95% CI: 10.51–15.31), and 0.07 (95% CI: 0.04–0.13) and 0.05 (95% CI:0.03–0.09) respectively. Conclusions: Exclusion of AMI 2 h after presentation in emergency patients with possible ACS can be achieved using hs-cTnT or hs-cTnI assays. Significant differences in specificity of these assays are relevant and if using the hs-cTnT assay, further clinical assessment in a larger proportion of patients would be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The world has experienced a large increase in the amount of available data. Therefore, it requires better and more specialized tools for data storage and retrieval and information privacy. Recently Electronic Health Record (EHR) Systems have emerged to fulfill this need in health systems. They play an important role in medicine by granting access to information that can be used in medical diagnosis. Traditional systems have a focus on the storage and retrieval of this information, usually leaving issues related to privacy in the background. Doctors and patients may have different objectives when using an EHR system: patients try to restrict sensible information in their medical records to avoid misuse information while doctors want to see as much information as possible to ensure a correct diagnosis. One solution to this dilemma is the Accountable e-Health model, an access protocol model based in the Information Accountability Protocol. In this model patients are warned when doctors access their restricted data. They also enable a non-restrictive access for authenticated doctors. In this work we use FluxMED, an EHR system, and augment it with aspects of the Information Accountability Protocol to address these issues. The Implementation of the Information Accountability Framework (IAF) in FluxMED provides ways for both patients and physicians to have their privacy and access needs achieved. Issues related to storage and data security are secured by FluxMED, which contains mechanisms to ensure security and data integrity. The effort required to develop a platform for the management of medical information is mitigated by the FluxMED's workflow-based architecture: the system is flexible enough to allow the type and amount of information being altered without the need to change in your source code.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper has three main aims. First, to trace – through the pages of the Journal – the changing ways in which lay understandings of health and illness have been represented during the 1979-2002 period. Second, to say something about the limits of lay knowledge (and particularly lay expertise) in matters of health and medicine. Third, to call for a re-assessment of what lay people can offer to a democratised and customer sensitive system of health care and to attempt to draw a boundary around the domain of expertise. In following through on those aims, the author calls upon data derived from three current projects. These latter concern the diagnosis of Alzheimer’s disease in people with Down’s syndrome; the development of an outcome measure for people who have suffered a traumatic brain injury; and a study of why older people might reject annual influenza vaccinations. Key words: Lay health beliefs, lay expertise, Alzheimer’s, Traumatic Brain Injury, Vaccinations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study assesses both the success of medical practitioners in accessing hazardous substances' information from product manufacturers and the accuracy and clinical usefulness of Material Safety Data Sheets (MSDS) presented by workers with suspected occupational contact dermatitis (OCD). 00 consecutively presented MSDS were collected from 42 workers attending an occupational dermatology clinic. Product manufacturers were contacted to verify ingredients. MSDS were evaluated for compliance with the Australian criteria for listing of OCD relevant information (sensitizers present at a concentration > or =1%, irritants present at a concentration > or =20%), and for clinical usefulness. All sensitizers were checked for clinical relevance to the worker's dermatitis. Manufacturers supplied product constituents for 77/100 MSDS. 58 MSDS satisfied the Australian standard. 57/58 MSDS were deemed clinically useful. Irritants were listed for 19/23 MSDS and sensitizers were listed for 30/68 MSDS (P = 0.001). 3 MSDS contained sensitizers, which were clinically relevant to the presenting worker's dermatitis, 1 appropriately listed, 1 present at > or =1% but not listed, and 1 present at <1% in the product and therefore, not required to be listed. Sensitizers are frequently omitted from MSDS and clinicians are often unsuccessful in obtaining crucial information from manufacturers. MSDS are inadequate for the protection and diagnosis of workers with suspected OCD.