969 resultados para Cone-beam computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In images with low contrast-to-noise ratio (CNR), the information gain from the observed pixel values can be insufficient to distinguish foreground objects. A Bayesian approach to this problem is to incorporate prior information about the objects into a statistical model. A method for representing spatial prior information as an external field in a hidden Potts model is introduced. This prior distribution over the latent pixel labels is a mixture of Gaussian fields, centred on the positions of the objects at a previous point in time. It is particularly applicable in longitudinal imaging studies, where the manual segmentation of one image can be used as a prior for automatic segmentation of subsequent images. The method is demonstrated by application to cone-beam computed tomography (CT), an imaging modality that exhibits distortions in pixel values due to X-ray scatter. The external field prior results in a substantial improvement in segmentation accuracy, reducing the mean pixel misclassification rate for an electron density phantom from 87% to 6%. The method is also applied to radiotherapy patient data, demonstrating how to derive the external field prior in a clinical context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate patient positioning is vital for improved clinical outcomes for cancer treatments using radiotherapy. This project has developed Mega Voltage Cone Beam CT using a standard medical linear accelerator to allow 3D imaging of the patient position at treatment time with no additional hardware required. Providing 3D imaging functionality at no further cost allows enhanced patient position verification on older linear accelerators and in developing countries where access to new technology is limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the accuracy of two imaging methods in diagnosing apical periodontitis (AP) using histopathological findings as a gold standard. Methods: The periapex of 83 treated or untreated roots of dogs` teeth was examined using periapical radiography (PR), cone-beam computed tomography (CBCT) scans, and histology. Sensitivity, specificity, predictive values, and accuracy of PR and CBCT diagnosis were calculated. Results: PR detected AP in 71% of roots, a CBCT scan detected AP in 84%, and AP was histologically diagnosed in 93% (p = 0.001). Overall, sensitivity was 0.77 and 0.91 for PR and CBCT, respectively. Specificity was 1 for both. Negative predictive value was 0.25 and 0.46 for PR and CBCT, respectively. Positive predictive value was 1 for both. Diagnostic accuracy (true positives + true negatives) was 0.78 and 0.92 for PR and CBCT (p = 0.028), respectively. Conclusion: A CBCT scan was more sensitive in detecting AP compared with PR, which was more likely to miss AP when it was still present. (J Endod 2009;35:1009-1012)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare the favorable outcome of root canal treatment determined by periapical radiographs (PRs) and cone beam computed tomography (CBCT) scans. Ninety-six roots of dogs` teeth were used to form four groups (n = 24). In group 1, root canal treatments were performed in healthy teeth. Root canals in groups 2 through 4 were infected until apical periodontitis (AP) was radiographically confirmed. Roots with AP were treated by one-visit therapy in group 2, by two-visit therapy in group 3, and left untreated in group 4. The radiolucent area in the PRs and the volume of CBCT-scanned periapical lesions were measured before and 6 months after the treatment. In groups 1, 2, and 3, a favorable outcome (lesions absent or reduced) was shown in 57 (79%) roots using PRs but only in 25 (35%) roots using CBCT scans (p = 0.0001). Unfavorable outcomes occurred more frequently after one-visit therapy than two-visit therapy when determined by CBCT scans (p = 0.023). (J Endod 2009; 35:723-726)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate craniofacial asymmetry by using 2-dimensional (2D) poster-oanterior cephalometric images, 3-dimensional cone-beam computed tomography (CBCT), and physical measurements (gold standard). Methods: Ten dry human skulls were assessed, and radiopaque markers were placed on 17 skeletal landmarks. Twenty linear measurements were taken on each side to compare the right and left sides and to compare these measurements with the physical measurements made with a digital caliper. To acquire the 2D posteroanterior radiographs, an Extraoral Phosphor Storage Plate (Air Techniques, Chicago, Ill) was used as the image receptor with a Eureka x-ray-Duocon Machlett unit (Machlett Laboratores, Chicago, Ill). Three-dimensional imaging data were acquired from a CB MercuRay (Hitachi Medical, Tokyo, Japan). Results: on average, the right side was larger than the left for most of the 20 distances evaluated in the digital 2D and the CBCT images, and there was poor agreement between the digital 2D images and the physical measurements (kappa = 0.0609) and almost perfect agreement (kappa = 0.92) between the CBCT and physical measurements when individual measurements were considered. Conclusions: Human skulls, with no apparent asymmetry, had some differences between the right and left sides, with dominance for the right side but with no clinical significance. CBCT can better evaluate craniofacial morphology when compared with digital 2D images. (Am J Orthod Dentofacial Orthop 2011; 139: e523-e531)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The calcifying cystic odontogenic tumour (CCOT) is a rare benign cystic neoplasm not infrequently associated with odontoma. This report documents a case of CCOT associated with compound odontoma arising in the anterior maxilla in a 25-year-old woman. Conventional radiographs showed a large calcified mass with poorly visualized radiolucent margins. The extent and condition of the internal structure of the CCOT associated with odontoma was able to be determined based on radiographic findings from cone beam computed tomography. This advanced image technique proved to be extremely useful in the radiographic assessment of this particular neoplasm of the jawbones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Study Design: Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K2HPO4) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K2HPO 4 phantoms were measured, and the relationship between CT numbers and K2HPO4 concentration was examined. The measured CT numbers of the K2HPO4 phantoms were compared between anatomical sites. Results: At all six anatomical locations, there was a strong linear relationship between CT numbers and K2HPO4 concentration (R 2 > 0.93). However, the absolute CT numbers varied considerably with the anatomical location. Conclusion: The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars. Objectives: The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated. Material and Methods: Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1) and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p<0.05. Results: No significant differences (p>0.05) were observed between the instruments, regarding the root canal area and dentin wall thickness. Conclusion: Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report describes the interdisciplinary treatment of a 19-year-old Brazilian man with a Class I malocclusion, a hyperdivergent profile, an anterior open bite, and signs of temporomandibular joint internal derangement. The treatment plan included evaluation with a temporomandibular joint specialist and a rheumatologist, orthodontic appliances, and maxillomandibular surgical advancement with counterclockwise rotation. Cone-beam computed tomography images were taken before and after surgery at different times and superimposed at the cranial base to assess the changes after orthognathic surgery and to monitor quantitatively the internal derangement of the temporomandibular joints and surgical relapse. Our protocol can improve the orthodontist's understanding of surgical instability, demonstrate the clinical value of cone-beam computed tomography analysis beyond the multiplanar reconstruction, and guide patient management for the best outcome possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Horizontal root fractures (HRF) usually affect the anterior teeth as a result of trauma, and generally heal spontaneously, depending on the vitality of the pulp. Diagnosis based on clinical findings, sensitivity tests, and radiographic examination is important to determine the presence of a root fracture and to prevent a root fracture from passing unnoticed. Cone-beam computed tomography (CBCT) has been used successfully for diagnosis and prognosis imaging of root fractures and has proved to be superior to other radiographic methods. This study reports two cases of dental trauma caused by a collision and a sports accident. The patients suffered horizontal root fractures in the maxillary left central incisor and in the mandibular left central incisor. The diagnosis of root fracture was confirmed by cone-beam computed tomography (CBCT) images, which also demonstrated spontaneous healing of the fracture line. The repair occurred by interposition of connective tissue in the former case and by interposition of bone and connective tissue in the latter case. The final diagnoses of both cases were based on CBCT images, indicating the importance of a CBCT examination to reach a firm diagnosis and to follow the healing process of root fracture cases, avoiding unnecessary radical endodontic treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.