933 resultados para Cement-loaded, Kuntscher Nail, Revision, Hip Arthroplasty, Bone Loss


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The number of revision hip arthroplasties is increasing but several aspects of this procedure could be improved. One method of reducing intra-operative complications is the cement-in-cement technique. This procedure entails cementing a smaller femoral prosthesis into the existing stable cement mantle. The aim of this systematic review is to provide a concise overview of the existing historical, operative, biomechanical and clinical literature on the cement-in-cement construct.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between 1987 and 1999, 540 revision total hip replacements in 487 patients were performed at our institution with the femoral impaction grafting technique with a cemented femoral stem. All patients were prospectively followed for 2-15years post-operatively with no loss to follow-up. 494 hips remained successfully in situ at an average 6.7years. The ten year survival rate was 98.0% (95% CI 96.2 to 99.8) with aseptic loosening as the endpoint and 84.2% (95% CI 78.5 to 89.9) for re-operation for any reason. Indication for surgery and the use of any kind of reinforcement significantly influenced outcome (p<0.001). This is the largest known series of revision THR with femoral impaction grafting and the results support continued use of this technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La révision d’arthroplastie de la hanche en cas d’important déficit osseux acétabulaire peut être difficile. Les reconstructions avec cupule de très grand diamètre ou cupule « jumbo » (≥ 62 mm chez la femme et ≥ 66 mm chez l’homme) sont une option thérapeutique. Nous voulions évaluer la préservation et la restauration du centre de rotation de la hanche reconstruite en la comparant au coté controlatéral sain ou selon les critères de Pierchon et al. Nous voulions également évaluer la stabilité du montage à un suivi d’au moins 2 ans. Il s’agissait de 53 cas consécutifs de révision acétabulaire pour descellement non septique avec implantation d’une cupule jumbo sans ciment à l’Hôpital Maisonneuve-Rosemont. Le déficit osseux évalué selon la classification de Paprosky et al. Les cupules implantées avaient un diamètre moyen de 66 mm (62-81) chez les femmes et 68 mm (66-75) chez les hommes. L’allogreffe osseuse morcelée et massive était utilisée dans 34 et dans 14 cas respectivement. La cupule a été positionnée avec un angle d’inclinaison moyen de 41.3° (26.0-53.0). Le centre de rotation de la hanche reconstruite a été jugé satisfaisant dans 78% de cas sur l'axe médiolatéral, 71% sur l'axe craniopodal et amélioré dans 27% dans cet axe. Au recul moyen radiologique de 84.0 mois (24.0-236.4) et clinique de 91.8 mois (24.0 – 241.8): 6 cas étaient décédés, 3 perdus au suivi. On a observé le descellement radiologique dans un 1 cas, la luxation récidivante dans 5 cas et l’infection dans 4 cas. Le retrait de la cupule a été effectué dans 2 cas pour infection. L’ostéointégration des greffons osseux était complète dans tous les cas sauf 3. Les scores cliniques étaient pour le HHS de 82 +/-17, le WOMAC de 86 +/- 14 et le SF-12 physique de 46 +/- 12 et mental 53 +/-13. La cupule jumbo peut être considérée comme un moyen fiable pour gérer le déficit osseux dans les révisions acétabulaires. Elle permet de conserver ou d’améliorer la position du centre de rotation physiologique de la hanche. La fixation sans ciment favorise l’ostéointégration de la cupule et permet une stabilité à moyen terme. Le taux de complications est comparable ou inférieur à d'autres procédures de reconstruction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Total hip arthroplasty carried out using cemented modular-neck implants provides the surgeon with greater intra-operative flexibility and allows more controlled stem positioning. Methods In this study, finite element models of a whole femur implanted with either the Exeter or with a new cemented modular-neck total hip arthroplasty (separate, neck and stem components) were developed. The changes in bone and cement mantle stress/strain were assessed for varying amounts of neck offset and version angle for the modular-neck device for two simulated physiological load cases: walking and stair climbing. Since the Exeter is the gold standard for polished cemented total hip arthroplasty stem design, bone and cement mantle stresses/strains in the modular-neck finite element models were compared with finite element results for the Exeter. Findings For the two physiological load cases, stresses and strains in the bone and cement mantle were similar for all modular-neck geometries. These results were comparable to the bone and cement mechanics surrounding the Exeter. These findings suggest that the Exeter and the modular neck device distribute stress to the surrounding bone and cement in a similar manner. Interpretation It is anticipated that the modular-neck device will have a similar short-term clinical performance to that of the Exeter, with the additional advantages of increased modularity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Infection remains a severe complication following a total hip replacement. If infection is suspected when revision surgery is being performed, additional gentamicin is often added to the cement on an ad hoc basis in an attempt to reduce the risk of recurrent infection.

Methods and results: In this in vitro study, we determined the effect of incorporating additional gentamicin on the mechanical properties of cement. We also determined the degree of gentamicin release from cement, and also the extent to which biofilms of clinical Staphylococcus spp. isolates form on cement in vitro. When gentamicin was added to unloaded cement (1–4 g), there was a significant reduction in the mechanical performance of the loaded cements compared to unloaded cement. A significant increase in gentamicin release from the cement over 72 h was apparent, with the amount of gentamicin released increasing significantly with each additional 1 g of gentamicin added. When overt infection was modeled, the incorporation of additional gentamicin did result in an initial reduction in bacterial colonization, but this beneficial effect was no longer apparent by 72 h, with the clinical strains forming biofilms on the cements despite the release of high levels of gentamicin.

Interpretation: Our findings indicate that the addition of large amounts of gentamicin to cement is unlikely to eradicate bacteria present as a result of an overt infection of an existing implant, and could result in failure of the prosthetic joint because of a reduction in mechanical performance of the bone cement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Written by the surgeons of the Exeter Hip Team and their colleagues from around the world, this book describes 40 years of innovation and development with cemented hip replacement. Topics covered include the basic science behind successful cemented hip replacement, modern surgical techniques and recent advances. There is also extensive coverage of the revision techniques developed at Exeter and elsewhere, focussing on femoral and acetabular impaction grafting. Each chapter is a self-contained article with an emphasis, where appropriate, on practical techniques and surgical tips, supported by line drawings and intra-operative photographs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

* Propoerties and use of acrylic cement * Design and biomechaniscs of a cemented hip replacement * The science of loosening, lysis and wear * Preparation of patients for surgery * Potential complications and their avoidance * Modern primary surgical techniques and new developments * Complex primary hip replacement and specialist techniques * Outcomes of cemented hip replacement * Principles of revision hip replacement * Basic science of bone grafting in revision surgery * Femoral acetabular impaction bone grafting techniques * Results of revision with bone graft and cement

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Periprosthetic joint infection (PJI) after THA is a major complication with an incidence of 1-3%. We report our experiences with a technique using a custom-made articulating spacer (CUMARS) at the first of two-stage treatment for PJI. This technique uses widely available all-polyethylene acetabular components and the Exeter Universal stem, fixed using antibiotic loaded acrylic cement. Seventy-six hips were treated for PJI using this technique. Performed as the first of a two-stage procedure, good functional results were commonly seen, leading to postponing second stage indefinitely with retention of the CUMARS prosthesis in 34 patients. The CUMARS technique presents an alternative to conventional spacers, using readily available components that are well tolerated, allowing weight bearing and mobility, and achieving comparable eradication rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). Patients and Methods: A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. Results: There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. Conclusion: Kaplan–Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. Take home message: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacterial infection primarily with Staphylococcus spp. and Propionibacterium acnes remains a significant complication following total hip replacement. In this in vitro study, we investigated the efficacy of gentamicin loading of bone cement and pre- and postoperative administration of cefuroxime in the prevention of biofilm formation by clinical isolates. High and low initial inocula, representative of the number of bacteria that may be present at the operative site as a result of overt infection and skin contamination, respectively, were used. When a high initial inoculum was used, gentamicin loading of the cement did not prevent biofilm formation by the 10 Staphylococcus spp. and the 10 P. acnes isolates tested. Similarly, the use of cefuroxime in the fluid phase with gentamicin-loaded cement did not prevent biofilm formation by four Staphylococcus spp. and four P. acnes isolates tested. However, when a low bacterial inoculum was used, a combination of both gentamicin-loaded cement and cefuroxime prevented biofilm formation by these eight isolates. Our results indicate that this antibiotic combination may protect against infection after intra-operative challenge with bacteria present in low numbers as a result of contamination from the skin but would not protect against bacteria present in high numbers as a result of overt infection of an existing implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the effectiveness of pulse-lavage brushing followed by hydrogen peroxide-gauze packing with either technique alone or normal-saline irrigation in bone-bed preparation for cemented total hip arthroplasty. 44 fresh-frozen ox femoral canals were prepared for cemented total hip arthroplasty using 4 techniques: normal-saline irrigation, pulse-lavage brushing, hydrogen peroxide-soaked gauze packing, and a combination of the latter 2 techniques. The maximum tensile pull-out force required to separate the prosthesis from the femoral canal was measured as an indicator of the strength of the cement-bone interface. The mean pull-out force to separate the prosthesis from the femoral canal was significantly higher in specimens prepared with pulse-lavage brushing followed by hydrogen peroxide-soaked gauze packing or pulse-lavage brushing alone than those prepared with normal-saline irrigation or hydrogen peroxide-soaked gauze packing alone 300(p<0.001). Pulse-lavage brushing is more effective at cleansing the femoral canal and increasing mechanical strength at the cement-bone interface than preparation with normal-saline irrigation or hydrogen peroxide-soaked gauze packing.