19 resultados para Cardiotocography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the FHR parameters in term pregnancies complicated by asthma. Study design: prospective cross-sectional study performed between July 2008 and November 2009. Twenty-one singleton pregnancy between 36 and 40 weeks gestation with diagnosis of maternal asthma and no current use of oral corticosteroids were compared with 30 pregnancies without morbidities at the same gestational age. The computerized cardiotocography (System 8002, Sonicaid) was performed and 30 min analysis was studied. Statistical analysis included Student's t-test or Mann-Whitney U test for comparisons between groups. Categorical data were compared using the chi(2)-test or Fisher's exact test. Results: There were no significant differences in FHR parameters analyzed by computerized cardiotocography: basal FHR (p = 0.80), number of accelerations >10 bpm (p = 0.08) or >15 bpm (p = 0.20), duration of high episodes (p = 0.70), duration of low episodes (p = 0.46) and STV (p = 0.66). Asthmatic mothers presented mean number of fetal movement per hour significantly lower than control group (34.6 +/- 28.2 vs. 60.6 +/- 43.1, p = 0.02). Conclusion: Computerized cardiotocography demonstrates no association between the abnormal parameters of FHR and maternal asthma in term pregnancies. Maternal asthma was associated with less fetal movements per hour, suggesting further studies on the counting of fetal movements in pregnant women with asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese propõe uma contribuição para as análises do campo obstétrico pré-natal sendo o seu objeto a transmissão e circulação do "saber autorizador" a partir das experiências de mediação tecnológica com a cardiotocografia num contexto institucional local. O principal objetivo é mostrar que o campo obstétrico contemporâneo se constrói a partir da afirmação do feto/bebê como seu símbolo dominante. Para tanto direcionei o meu olhar para a dinâmica dos agentes institucionais em torno da tecnologia da cardiotocografia, observando as relações entre o conceito de "saber autorizador" e o simbolismo dominante contextual. Embora o conceito de "saber autorizador" tenha sido originalmente proposto para a compreensão da dinâmica dos agentes do campo obstétrico, ele foi atribuído apenas aos profissionais médicos que dominam as tecnologias de controle da condição fetal, portanto, supondo que a autoridade deste saber se encontra circunscrito a este grupo de agentes. No entanto, quando se apresenta a perspectiva da incorporação deste saber pelos múltiplos agentes do campo incluindo as gestantes, encontramos o direcionamento conjunto para uma categoria central híbrida que confere autoridade tanto ao saber quanto à experiência do grupo articulado à tecnologia obstétrica. A metodologia consistiu na observação participante da dinâmica da cardiotocografia numa Maternidade Pública do município do Rio de Janeiro, incluindo entrevistas semi-estruturadas com cinco médicos, agentes a quem o saber autorizador é originalmente atribuído. As representações dos entrevistados disponibilizaram quatro categorias: a história, os valores, os instrumentos tecnológicos e as emoções que são incorporadas/corporificadas em torno da relação do saber e da experiência de cuidado com o feto/bebê. Estas categorias serviram para a análise da observação do campo, resultando na construção da nova categoria - a vitalidade fetal - que verifica o simbolismo dominante conferido pelo feto/bebê e que mostra de maneira aprofundada o movimento contemporâneo do campo obstétrico em direção à perinatologia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Computação e Instrumentação Médica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: Después del ingreso de la monitoría fetal electrónica como estudio de bienestar fetal, se ha considerado por décadas que un aporte de carbohidratos a la gestante antes de la realización de la monitoría fetal influye en el reporte pero existen estudios que consideran que los niveles de glicemia materna no afecta la variabilidad de la monitoría fetal. Metodología: Se realizó un estudio de corte transversal, para evaluar el efecto de la glicemia materna en la monitoría fetal electrónica comparando los valores de glicemia materna con su resultado, según la categorización del ACOG. Las principales variables fueron las horas de ayuno, valores de glicemia, variabilidad de la monitoría fetal y presencia de aceleraciones. Resultados: Se incluyeron un total de 60 pacientes, que ingresaron al servicio de obstetricia y ginecología del Hospital Universitario Mayor Méderi en el periodo de estudio. No se encontraron diferencias estadísticamente significativas entre los resultados de monitoría fetal y los valores de glicemia materna. Ninguna paciente presentó monitoría categoría III (según categorización de la ACOG). Discusión Se requieren estudios analíticos más amplios para evaluar el papel de la glicemia en el resultado de la monitoría, pero el presente estudio sugiere que no existe relación entre la glicemia materna y el resultado de la monitoría fetal electrónica en la categorización del Colegio Americano De Ginecología Y Obstetricia (ACOG).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, we have investigated the evidence of fetal heart rate asymmetry and how the fetal heart rate asymmetry changes before and after 35 weeks of gestation. Noninvasive fetal electrocardiogram (fECG) signals from 45 pregnant women at the gestational age from16 to 41 weeks with normal single pregnancies were analysed. A nonlinear parameter called heart rate asymmetry (HRA) index that measures time asymmetry of RR interval time-series signal was used to understand the changes of HRA in early and late fetus groups. Results indicate that fetal HRA measured by Porta's Index (PI) consistently increases after 35 weeks gestation compared to foetus before 32 weeks of gestation. It might be due to significant changes of sympatho-vagal balance towards delivery with more sympathetic surge. On the other hand, Guzik's Index (GI) showed a mixed effect i.e., increases at lower lags and decreases at higher lags. Finally, fHRA could potentially help identify normal and the pathological autonomic nervous system development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: avaliar percepções e sentimentos de puérperas adultas e adolescentes, relacionados ao filho e a assistência materno-infantil, em hospital universitário de nível terciário. MÉTODOS: estudo transversal, envolvendo 180 puérperas, no Alojamento Conjunto (AC) e no Berçário Interno (BI) do Hospital das Clínicas da Faculdade de Medicina de Botucatu , entrevistadas no segundo e terceiro dia pós-parto e distribuídas em três grupos: adultas primíparas, adultas multíparas e adolescentes. Para comparação entre grupos e locais de internação utilizou-se o chi2 ou teste de Fisher. RESULTADOS: ultrasom obstétrico e cardiotocografia tiveram impacto positivo na emoção materna. Houve pouca diferença entre os grupos quanto aos sentimentos antes e após o parto, sendo felicidade, amor, responsabilidade, ansiedade e medo os mais freqüentes. A culpa predominou nas adolescentes do BI. As percepções relacionadas ao filho, a avaliação da assistência e equipe, não diferiram entre adultas e adolescentes. Nas duas enfermarias o relacionamento entre mães e cuidadores foi bom, as mães mostraram-se satisfeitas com a equipe e a assistência, mas o aleitamento materno foi pouco valorizado e poucas mães conheciam o médico. CONCLUSÕES: está ocorrendo um processo de humanização na assistência materno-infantil deste hospital universitário, mas alguns aspectos precisam ser melhorados, especialmente a valorização do aleitamento materno e a individualização no contato médico-paciente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a associação entre índice de Apgar menor que sete no 5º minuto, os fatores pré-natais e resultados pós-natais. MÉTODOS: Trata-se de estudo retrospectivo com 27.252 recém-nascidos em maternidade escola com população de baixo risco obstétrico, de janeiro de 2003 a dezembro de 2010. Prontuários de todos os casos com índice de Apgar < 7 no 5º minuto (n = 121; - 0,4%) e de 363 casos com Apgar > 7 no 5º minuto, escolhidos ao acaso, foram revisados. Os principais desfechos estudados foram: óbito neonatal, insuficiência respiratória neonatal, necessidade de intubação orotraqueal e de unidade terapia intensiva (UTI) neonatal e encefalopatia hipóxico-isquêmica. RESULTADOS: Após análise de regressão múltipla, desacelerações tardias (DIP II) (OR: 2,4; IC95%: 1,4-4,1) e período expulsivo prolongado (OR: 3,3; IC 95%: 1,3-8,3) se associaram com Apgar < 7 no 5º minuto; assim como com insuficiência respiratória ao nascimento (OR: 3,0; IC 95%: 1,3-6,9), intubação traqueal (OR: 2,5; IC 95%: 1,2-4,8), necessidade de UTI neonatal (OR: 9,5; IC 95%: 6,7-16,8) e encefalopatia hipóxico-isquêmica (OR: 14,1; IC 95%: 3,6-54,7). Nenhuma outra variável prénatal se associou com Apgar < 7 no 5º minuto (p < 0,05). CONCLUSÃO: DIP II e período expulsivo prolongado estão associados com Apgar < 7 no 5º minuto em população obstétrica de baixo risco; situação essa relacionada com maior risco de insuficiência respiratória no parto, necessidade de suporte ventilatório e encefalopatia hipóxico-isquêmica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pregnancies complicated by diabetes account for about 7% of all pregnancies attended by the Brazilian Unified Healthcare System (SUS) and are one of the main causes of maternal/perinatal morbidity and mortality in Brazil. Considering the importance of this topic, this article presents an update of diabetes classification, diagnostic criteria, maternal/perinatal outcomes, and both clinical and obstetric prenatal care. Even though there is no consensus about screening and diagnostic standards, the investigation of hyperglycemia in all risk pregnancies is recommended. The importance of adequate metabolic control is emphasized in order to improve maternal and neonatal outcomes. Finally, the development of educational programs is encouraged, viewing not only good gestational outcome but also long-term changes in the lifestyle of these women. © by São Paulo State University.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the association between Apgar scores of less than seven at five minutes (AS(5min) < 7) and antenatal factors and postnatal outcomes. Methods: A retrospective cohort and case-control study of 27,252 consecutive term newborns in a low risk obstetrical population between January 2003 and December 2010. Maternal and infant databases were reviewed from all cases with AS(5min) < 7 (n = 121; 0.4%) and 363 cases with AS(5min) >= 7 at 5 minutes who were randomly selected by a computer program. The main outcomes were neonatal death, newborn respiratory distress, need for orotracheal intubation and neonatal intensive care unit (NICU), and hypoxic-ischemic-encephalopathy. Results: After multiple regression analysis, repeated late decelerations on cardiotocography (OR: 2.4; 95% CI: 1.4-4.1) and prolonged second stage of labor (OR: 3.3; 95% CI: 1.3-8.3) were associated with AS(5min) < 7, as well as neonatal respiratory distress (OR: 3.0; 95% CI: 1.3-6.9), orotracheal intubation (OR: 2.5; 95% CI: 1.2-4.8), need for NICU (OR: 9.5; 95% CI: 6.7-16.8), and hypoxic-ischemic-encephalopathy (OR: 14.1; 95% CI: 3.6-54.7). No other antenatal factors were associated with AS(5min) < 7 (p > 0.05). Conclusion: Repeated late decelerations and prolonged second stage of labor in the low-risk population are predictors of AS(5min) < 7, a situation associated with increased risk of neonatal respiratory distress, need for mechanical ventilatory support and NICU, and hypoxic-ischemic-encephalopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring foetal health is a very important task in clinical practice to appropriately plan pregnancy management and delivery. In the third trimester of pregnancy, ultrasound cardiotocography is the most employed diagnostic technique: foetal heart rate and uterine contractions signals are simultaneously recorded and analysed in order to ascertain foetal health. Because ultrasound cardiotocography interpretation still lacks of complete reliability, new parameters and methods of interpretation, or alternative methodologies, are necessary to further support physicians’ decisions. To this aim, in this thesis, foetal phonocardiography and electrocardiography are considered as different techniques. Further, variability of foetal heart rate is thoroughly studied. Frequency components and their modifications can be analysed by applying a time-frequency approach, for a distinct understanding of the spectral components and their change over time related to foetal reactions to internal and external stimuli (such as uterine contractions). Such modifications of the power spectrum can be a sign of autonomic nervous system reactions and therefore represent additional, objective information about foetal reactivity and health. However, some limits of ultrasonic cardiotocography still remain, such as in long-term foetal surveillance, which is often recommendable mainly in risky pregnancies. In these cases, the fully non-invasive acoustic recording, foetal phonocardiography, through maternal abdomen, represents a valuable alternative to the ultrasonic cardiotocography. Unfortunately, the so recorded foetal heart sound signal is heavily loaded by noise, thus the determination of the foetal heart rate raises serious signal processing issues. A new algorithm for foetal heart rate estimation from foetal phonocardiographic recordings is presented in this thesis. Different filtering and enhancement techniques, to enhance the first foetal heart sounds, were applied, so that different signal processing techniques were implemented, evaluated and compared, by identifying the strategy characterized on average by the best results. In particular, phonocardiographic signals were recorded simultaneously to ultrasonic cardiotocographic signals in order to compare the two foetal heart rate series (the one estimated by the developed algorithm and the other provided by cardiotocographic device). The algorithm performances were tested on phonocardiographic signals recorded on pregnant women, showing reliable foetal heart rate signals, very close to the ultrasound cardiotocographic recordings, considered as reference. The algorithm was also tested by using a foetal phonocardiographic recording simulator developed and presented in this research thesis. The target was to provide a software for simulating recordings relative to different foetal conditions and recordings situations and to use it as a test tool for comparing and assessing different foetal heart rate extraction algorithms. Since there are few studies about foetal heart sounds time characteristics and frequency content and the available literature is poor and not rigorous in this area, a data collection pilot study was also conducted with the purpose of specifically characterising both foetal and maternal heart sounds. Finally, in this thesis, the use of foetal phonocardiographic and electrocardiographic methodology and their combination, are presented in order to detect foetal heart rate and other functioning anomalies. The developed methodologies, suitable for longer-term assessment, were able to detect heart beat events correctly, such as first and second heart sounds and QRS waves. The detection of such events provides reliable measures of foetal heart rate, potentially information about measurement of the systolic time intervals and foetus circulatory impedance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiotocography (CTG) is a widespread foetal diagnostic methods. However, it lacks of objectivity and reproducibility since its dependence on observer's expertise. To overcome these limitations, more objective methods for CTG interpretation have been proposed. In particular, many developed techniques aim to assess the foetal heart rate variability (FHRV). Among them, some methodologies from nonlinear systems theory have been applied to the study of FHRV. All the techniques have proved to be helpful in specific cases. Nevertheless, none of them is more reliable than the others. Therefore, an in-depth study is necessary. The aim of this work is to deepen the FHRV analysis through the Symbolic Dynamics Analysis (SDA), a nonlinear technique already successfully employed for HRV analysis. Thanks to its simplicity of interpretation, it could be a useful tool for clinicians. We performed a literature study involving about 200 references on HRV and FHRV analysis; approximately 100 works were focused on non-linear techniques. Then, in order to compare linear and non-linear methods, we carried out a multiparametric study. 580 antepartum recordings of healthy fetuses were examined. Signals were processed using an updated software for CTG analysis and a new developed software for generating simulated CTG traces. Finally, statistical tests and regression analyses were carried out for estimating relationships among extracted indexes and other clinical information. Results confirm that none of the employed techniques is more reliable than the others. Moreover, in agreement with the literature, each analysis should take into account two relevant parameters, the foetal status and the week of gestation. Regarding the SDA, results show its promising capabilities in FHRV analysis. It allows recognizing foetal status, gestation week and global variability of FHR signals, even better than other methods. Nevertheless, further studies, which should involve even pathological cases, are necessary to establish its reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The usefulness of umbilical artery Doppler velocimetry for the monitoring of diabetic pregnancies is controversial. The aim of the present study was to assess whether umbilical artery Doppler velocity waveform analysis can predict adverse perinatal outcomes for pregnancies complicated by pre-existing diabetes mellitus. Methods: All diabetic pregnancies (type 1 and 2) delivered at Mater Mothers' Hospital, Queensland, between 1 January 1995 and 31 December 1999 were included. All pregnant diabetic women were monitored with umbilical artery Doppler velocimetry at 28, 32, 36, and 38 weeks' gestation. Adverse perinatal outcome was defined as pregnancies with one or more of the following: small-for-gestational age, Caesarean section for non-reassuring cardiotocography, fetal acidaemia at delivery, 1-min Apgar of 3 or less, 5-min Apgar of less than 7, hypoxic ischaemic encephalopathy or perinatal death. Abnormal umbilical artery Doppler velocimetry was defined as a pulsatility index of 95th centile or higher for gestation. Results: One hundred and four pregnancies in women with pre-existing diabetes had umbilical arterial Doppler studies carried out during the study period. Twenty-three pregnancies (22.1%) had an elevated pulsatility index. If the scans were carried out within 2 weeks of delivery, 71% of pregnancies with abnormal umbilical Doppler had adverse outcomes (P < 0.01; likelihood ratio, 4.2). However, the sensitivity was 35%; specificity was 94%; positive predictive value was 80%; and negative predictive value was 68%. Only 30% of women with adverse perinatal outcomes had abnormal umbilical arterial Doppler flow. Conclusion: Umbilical artery Doppler velocimetry is not a good predictor of adverse perinatal outcomes in diabetic pregnancies.