999 resultados para Caffeine determination


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Caffeine determination using a fast-scan voltammetric procedure at a carbon fiber ultramicroelectrode (CF-UME) is described. The CF-UME was submitted to electrochemical pretreatment. Parameters such as number of acquisition cycles, scan rate, potential window, and the electrochemical surface pretreatment were optimized. Using the optimized conditions, it was possible to achieve a LDR from 10.0 up to 200 mu mol L-1, with a LOD of 3.33 mu mol L-1. The method has been applied in the determination of caffeine in commercial samples, with errors of 1.0-3.5% in relation to the label values and recoveries of 97-114% within the linear range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Caffeine determination using a fast-scan voltammetric procedure at a carbon fiber ultramicroelectrode (CF-UME) is described. The CF-UME was submitted to electrochemical pretreatment. Parameters such as number of acquisition cycles, scan rate, potential window, and the electrochemical surface pretreatment were optimized. Using the optimized conditions, it was possible to achieve a LDR from 10.0 up to 200 μmol L-1, with a LOD of 3.33 μmol L-1. The method has been applied in the determination of caffeine in commercial samples, with errors of 1.0-3.5% in relation to the label values and recoveries of 97-114% within the linear range.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A poly(Nile blue) modified glassy carbon electrode (PNBMGCE) was fabricated by electropolymerisation of Nile blue (NB) monomer using cyclic voltammetry (CV) and was used for the determination of paracetamol (ACOP), tramadol (TRA) and caffeine (CAF). The electrochemical investigations showed that PNB - film formed on the surface of glassy carbon electrode (GCE) improved the electroactive surface area and displayed a remarkable increase in the peak current and a substantial decrease in over potential of ACOP, TRA and CAF when compared to bare GCE. The dependence of peak current and potential on pH, sweep rate and concentration were also investigated at the surface of PNBMGCE. It showed good sensitivity and selectivity in a wide linear range from 2.0 x 10(-7) to 1.62 x 10(-5) M, 1.0 x 10(-6) to 3.1 x 10(-4) M and 8.0 x 10(-7) to 2.0 x 10(-5) M, with detection limits of 0.08, 0.5 and 0.1 mu M, for ACOP, TRA and CAF, respectively. The PNBMGCE was also successfully applied for the determination of ACOP, TRA and CAF in pharmaceutical dosage forms. (C) 2016 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Caffeine is the legal stimulant consumed most extensively by the human world population and may be found eventually in the urine and/or blood of race horses, the fact that caffeine is in foods led us to determine the highest no-effect dose (HNED) of caffeine on the spontaneous locomotor activity of horses and then to quantify this substance in urine until it disappeared. We built two behavioural stalls equipped with juxtaposed photoelectric sensors that emit infrared beams that divide the stall into nine sectors in a 'tic-tac-toe' fashion. Each time a beam was interrupted by a leg of the horse, a pulse was generated; the pulses were counted at 5-min intervals and stored by a microcomputer. Environmental effects were minimized by installing exhaust fans producing white noise that obscured outside sounds. One-way observation windows prevented the animals from seeing outside. The sensors were turned on 45 min before drug administration (saline control or caffeine), the animals were observed for up to 8 h after i.v. administration of 2.0, 2.5, 3.0 or 5.0 mg caffeine kg(-1). The HNED of caffeine for stimulation of the spontaneous locomotor activity of horses was 2.0 mg kg(-1). The quantification of caffeine in urine and plasma samples was done by gradient HPLC with UV detection. The no-effect threshold should not be greater than 2.0 mug caffeine ml(-1) plasma or 5.0 mug caffeine ml(-1) urine. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coffee is one of the most widely consumed beverages in the world and has a number of potential health benefits. Coffee may influence energy expenditure and energy intake, which in turn may affect body weight. However, the influence of coffee and its constituents – particularly caffeine – on appetite remains largely unexplored. The objective of this study was to examine the impact of coffee consumption (with and without caffeine) on appetite sensations, energy intake, gastric emptying, and plasma glucose between breakfast and lunch meals. In a double-blind, randomised crossover design. Participants (n = 12, 9 women; Mean ± SD age and BMI: 26.3 ± 6.3 y and 22.7 ± 2.2 kg•m−2) completed 4 trials: placebo (PLA), decaffeinated coffee (DECAF), caffeine (CAF), and caffeine with decaffeinated coffee (COF). Participants were given a standardised breakfast labelled with 13C-octanoic acid and 225 mL of treatment beverage and a capsule containing either caffeine or placebo. Two hours later, another 225 mL of the treatment beverage and capsule was administered. Four and a half hours after breakfast, participants were given access to an ad libitum meal for determination of energy intake. Between meals, participants provided exhaled breath samples for determination of gastric emptying; venous blood and appetite sensations. Energy intake was not significantly different between the trials (Means ± SD, p > 0.05; Placebo: 2118 ± 663 kJ; Decaf: 2128 ± 739 kJ; Caffeine: 2287 ± 649 kJ; Coffee: 2016 ± 750 kJ); Other than main effects of time (p < 0.05), no significant differences were detected for appetite sensations or plasma glucose between treatments (p > 0.05). Gastric emptying was not significantly different across trials (p > 0.05). No significant effects of decaffeinated coffee, caffeine or their combination were detected. However, the consumption of caffeine and/or coffee for regulation of energy balance over longer periods of time warrant further investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for saccharin determination in commercial artificial sweeteners is proposed. Saccharin present in several samples of artificial sweeteners is potentiometrically titrated with silver nitrate solution using a silver wire as the indicator electrode, coupled to a titroprocessor. The best pH range was from 3.0 to 3.5 and the detection limit of sodium saccharin was 2.5 mg/ml. Substances normally found along with saccharin in several commercial artificial sweeteners such as maltodextrin, glucose, sucrose, fructose, aspartame, cyclamate, caffeine, sorbitol, lactose, nitrate, methyl- and n-propyl-p-hydroxybenzoate, benzoic, citric and ascorbic acids do not interfere even in significant amounts (e.g. 20 excess relative to saccharin). Chloride ion interferes when present in concentrations larger than 10 mg l(-1); this interference is eliminated with previous extraction of the sweetener from the aqueous medium with ethyl acetate. The results obtained by applying the proposed method compared very favorably with those given by the HPLC method recommended by the FDA. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For controlled caffeine release, light-responsive membranes were developed. It was possible to produce membranes that reduced their caffeine permeability resistance by about 97% when irradiated with UV-light compared to measurements at daylight. This was achieved by grafting polymers possessing photochromic units onto track-edged polycarbonate membranes. Covalently linked coatings on porous polycarbonate membranes were obtained by plasma activation of the membrane surface followed by plasma-induced graft polymerization. Copolymerization of spiro-compounds during the coating process as well as postmodification of preformed coatings with spiropyran resulted in photochromic membranes. For the copolymerization process, the synthesis of five photochromic methacrylic and acrylic spiropyrans and spirooxazines was successfully performed. Additionally, a spiropyran with carboxylic acid functionality was synthesized for the postmodification process. This enabled us to postmodify polymeric materials containing alcohol or amine groups to obtain photochromic materials. UV-irradiation of these light-responsive membranes resulted in a strong colouration of the membrane, in a reduction of surface tension, which resulted in a decreased caffeine permeability resistance. The membranes were characterized using XPS for the elemental composition of the coating, contact angle measurements for the surface tension, solid-state UV/VIS measurements for the determination of the kinetic and stability properties, and two-photon microscopy for the localisation of the photochromic substance in the porous membrane.