992 resultados para CIRURGIA BUCO-MAXILO-FACIAL


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many patients seeking dental care wish to improve facial and smile aesthetics to be accepted in modern day society. In denture wearers, the physiological resorption causes atrophy mainly in the maxilla, being necessary to carry out reconstruction techniques and sometimes orthognathic surgery to improve occlusal stability and facial harmony. The aim of this study is to discuss the features related to the rehabilitation of edentulous patients with indication for reconstruction of the maxilla using bone grafts and orthognathic surgery by means of a clinical case. In the present case, after the prosthetic rehabilitation, the patient was full satisfied with obtained results and dismissed the initially proposed surgical protocol. Therefore, professionals should provide therapeutic options but the patient’s opinion should prevail provided its clinical feasibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Imagens de tomografia computadorizada (TC) permitem a visualização, sem distorções ou sobreposições, do complexo maxilo-facial, principalmente do osso alveolar. Estudos demonstraram boa reprodutibilidade e precisão da mensuração da altura da borda alveolar, todavia a influência da espessura óssea ainda é pouco descrita. Através da comparação com a mensuração direta, o objetivo deste estudo foi avaliar a precisão, reprodutibilidade e a influência da espessura óssea, na mensuração da altura da borda alveolar em imagens volumétricas e imagens bidimensionais multiplanares em TC de feixe cônico (TCFC) e em TC espiral (TCE). Utilizando 10 mandíbulas secas de humanos, 57 dentes anteriores foram tomografados em equipamentos iCAT (Imaging Science International, Hatfield, PA, EUA) e Brilliance 64 canais (Philips Eletronics, Eindhoven, Holanda), ambos utilizando voxels de 0,25 mm. Através de imagens volumétricas (3D) e imagens bidimensionais (2D) de cortes multiplanares, foi comparada a mensuração da altura da borda alveolar dessas imagens com a mensuração direta nas mandíbulas, feita por vestibular e lingual, por três avaliadores, com o auxílio de um paquímetro, totalizando 114 bordas alveolares medidas. Alta reprodutibilidade intra-avaliador (0,999 a 0,902) e interavaliador (0,998 e 0,868) foi observada através do índice de correlação intraclasse (ICC). Observou-se alta correlação entre a mensuração direta e indireta da altura da borda alveolar em imagens 2D, sendo r=0,923** e 0,916**, e em imagens 3D, com r=0,929** e 0,954*, em TCFC e TCE, respectivamente. Imagens 2D superestimam a altura da borda alveolar em 0,32 e 0,49 mm e imagens 3D em 0,34 e 0,30 mm, em TCFC e TCE respectivamente. Quando o osso alveolar apresenta espessura de no mínimo 0,6 mm a média da diferença entre medidas diretas e indiretas é de 0,16 e 0,28 mm em imagens 2D e de 0,12 e 0,03 mm em imagens 3D para TCFC e TCE respectivamente, sendo que 95% do limite de concordância varia de -0,46 a 0,79 mm e -0,32 a 0,88 mm em imagens 2D, e de -0,64 a 0,67 mm e -0,57 a 0,62 mm em imagens 3D, para TCFC e TCE respectivamente. Quando o osso alveolar é mais fino do que 0,6 mm a TC é imprecisa, pois 95% do limite de concordância variou de -1,74 a 5,42 mm e -1,64 a 5,42 mm em imagens 2D, e de -3,70 a 4,28 mm e -3,49 a 4,25 mm em imagens 3D, para TCFC e TCE respectivamente. Conclui-se que a mensuração da altura da borda alveolar através de imagens tomográficas apresenta alta reprodutibilidade, sendo que quando a borda alveolar apresenta pelo menos 0,6 mm, a precisão da mensuração é alta, todavia quando esta espessura é menor do que 0,6 mm a técnica é imprecisa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing interest in coral culture for biotechnological applications, to supply the marine aquarium trade, or for reef restoration programs, has prompted researchers to optimize coral culture protocols, with emphasis to ex situ production. When cultured ex situ, the growth performance of corals can be influenced by several physical, chemical and biological parameters. For corals harbouring zooxanthellae, light is one of such key factors, as it can influence the photosynthetic performance of these endosymbionts, as well as coral physiology, survival and growth. The economic feasibility of ex situ coral aquaculture is strongly dependent on production costs, namely those associated with the energetic needs directly resulting from the use of artificial lighting systems. In the present study we developed a versatile modular culture system for experimental coral production ex situ, assembled solely using materials and equipment readily available from suppliers all over the world; this approach allows researchers from different institutions to perform truly replicated experimental set-ups, with the possibility to directly compare experimental results. Afterwards, we aimed to evaluate the effect of contrasting Photosynthetically Active Radiation (PAR) levels, and light spectra emission on zooxanthellae photochemical performance, through the evaluation of the maximum quantum yield of PSII (Fv/Fm) (monitored non-invasively and non-destructively through Pulse Amplitude Modulation fluorometry, PAM), chlorophyll a content (also determined non-destructively by using the spectral reflectance index Normalized Difference Vegetation Index, NDVI), photosynthetic and accessory pigments, number of zooxanthellae, coral survival and growth. We studied two soft coral species, Sarcophyton cf. glaucum and Sinularia flexibilis, as they are good representatives of two of the most specious genera in family Alcyoniidae, which include several species with interest for biotechnological applications, as well as for the marine aquarium trade; we also studied two commercially important scleractinian corals: Acropora formosa and Stylophora pistillata. We used different light sources: hydrargyrum quartz iodide (HQI) lamps with different light color temperatures, T5 fluorescent lamps, Light Emitting Plasma (LEP) and Light Emitting Diode (LED). The results achieved revealed that keeping S. flexibilis fragments under the same light conditions as their mother colonies seems to be photobiologically acceptable for a short-term husbandry, notwithstanding the fact that they can be successfully stocked at lower PAR intensities. We also proved that low PAR intensities are suitable to support the ex situ culture S. cf. glaucum in captivity at lower production costs, since the survival recorded during the experiment was 100%, the physiological wellness of coral fragments was evidenced, and we did not detect significant differences in coral growth. Finally, we concluded that blue light sources, such as LED lighting, allow a higher growth for A. formosa and S. pistillata, and promote significant differences on microstructure organization and macrostructure morphometry in coral skeletons; these findings may have potential applications as bone graft substitutes for veterinary and/or other medical uses. Thus, LED technology seems to be a promising option for scleractinian corals aquaculture ex situ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Bone graft procedures have been used commonly in buco-maxillo-facial surgery. For this reason, many researchers have evaluated the bone substitutes.Purpose:The present study evaluated soft and hard tissue reactions to two different hydroxyapatites HAs (synthetic HA and natural HA) and bioactive glass implanted into the sockets immediately after extraction.Materials and Methods:First and third upper and lower premolars, on both sides, were extracted from six female dogs. The alveolar sockets were randomly assigned to four groups: Group 1 - control (unfilled), Group 2 - filled with synthetic hydroxyapatite, Group 3 - filled with bovine bone mineral (natural HA), and Group 4 - filled with bioactive glass. The animals were euthanized at 4 weeks (n = 2), 8 weeks (n = 2), and 28 weeks (n = 2) after extraction. The mandible and maxilla of each animal were removed for histological analysis to determine soft tissue reactions, newly formed bone, bone characteristics, and presence or absence of implanted materials.Results:Most particles of synthetic hydroxyapatite had bone formation on their surface, although some particles showed a layer of fibrous connective tissue. The bovine bone mineral group exhibited particles partially replaced with bone formation. The bioactive glass group showed particles with a thin layer of calcified tissue, but was absent in some specimens, suggesting complete resorption.Conclusion:All biomaterials had similar behavior. Bovine bone mineral, compared to synthetic hydroxyapatite and bioactive glass, showed a larger number of particles covered with osseous tissue. All biomaterials interfered with the socket repair process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A clinical investigation was undertaken to find out the prevalence of craniomandibular signs and symptoms in a group of 11 patients with labiopalatal lesions. The number and distribution of occlusal contacts was evaluated through questionnaire, clinical examination and analysis of mounted casts in partially adjustable articulators in the position of maximum inter cuspation. The most frequent signs and symptoms were articular sounds and lateral pterygoid muscle tenderness to palpation followed by restriction of mouth opening and sensation of tiredness. The number of occlusal contacts was small, mean of 5 contacts per patient, and the site was considered as atypical, 62% of them were on inclined plane surfaces , suggesting occlusal instability. The frequency of signs and symptoms was low and they were of a mild character. The most prevailing signs of craniomandibular dysfunction - articular sounds, muscular tenderness to palpation and restriction of mouth opening - was noticed in only one of the patients