864 resultados para CASE SERIES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Ankle arthrodesis results in measurable improvements in terms of pain and function in patients with end-stage ankle arthritis. Arthroscopic ankle arthrodesis has gained increasing popularity, with reports of shorter hospital stays, shorter time to solid fusion, and equivalent union rates when compared with open arthrodesis. However, there remains a lack of high-quality prospective data. METHODS We evaluated the results of open and arthroscopic ankle arthrodesis in a comparative case series of patients who were managed at two institutions and followed for two years. The primary outcome was the Ankle Osteoarthritis Scale score, and secondary outcomes included the Short Form-36 physical and mental component scores, the length of hospital stay, and radiographic alignment. There were thirty patients in each group. RESULTS Both groups showed significant improvement in the Ankle Osteoarthritis Scale score and the Short Form-36 physical component score at one and two years. There was significantly greater improvement in the Ankle Osteoarthritis Scale score at one year and two years and shorter hospital stay in the arthroscopic arthrodesis group. Complications, surgical time, and radiographic alignment were similar between the two groups. CONCLUSIONS Open and arthroscopic ankle arthrodesis were associated with significant improvement in terms of pain and function as measured with the Ankle Osteoarthritis Scale score. Arthroscopic arthrodesis resulted in a shorter hospital stay and showed better outcomes at one and two years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The two major subtypes of diffuse large B-cell lymphoma (DLBCL) (germinal centre B-cell - like (GCB-DLBCL) and activated B-cell - like (ABC-DLBCL)) are defined by means of gene expression profiling (GEP). Patients with GCB-DLBCL survive longer with the current standard regimen R-CHOP than patients with ABC-DLBCL. As GEP is not part of the current routine diagnostic work-up, efforts have been made to find a substitute than involves immunohistochemistry (IHC). Various algorithms achieved this with 80-90% accuracy. However, conflicting results on the appropriateness of IHC have been reported. Because it is likely that the molecular subtypes will play a role in future clinical practice, we assessed the determination of the molecular DLBCL subtypes by means of IHC at our University Hospital, and some aspects of this determination elsewhere in Switzerland. The most frequently used Hans algorithm includes three antibodies (against CD10, bcl-6 and MUM1). From records of the routine diagnostic work-up, we identified 51 of 172 (29.7%) newly diagnosed and treated DLBCL cases from 2005 until 2010 with an assigned DLBCL subtype. DLBCL subtype information was expanded by means of tissue microarray analysis. The outcome for patients with the GCB subtype was significantly better compared with those with the non-GC subtype, independent of the age-adjusted International Prognostic Index. We found a lack of standardisation in the subtype determination by means of IHC in Switzerland and significant problems of reproducibility. We conclude that the Hans algorithm performs well in our hands and that awareness of this important matter is increasing. However, outside clinical trials, vigorous efforts to standardise IHC determination are needed as DLBCL subtype-specific therapies emerge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Although extended-release (XR) formulations are recognized to bear some risk of pharmacobezoar formation in overdose, there are no previously documented reports of this phenomenon with quetiapine. We describe nine cases of pharmacobezoar formation in acute quetiapine XR overdose. METHODS Observational case series of all patients who underwent gastroscopy after quetiapine XR overdose, which were reported by physicians to the Swiss Toxicological Information Centre between January 2010 and December 2012, with detailed analysis of cases with documented pharmacobezoar. RESULTS Gastric pharmacobezoars were detected in 9 out of 19 gastroscopic evaluations performed during the study period. All these patients ingested a large dose of quetiapine XR (10-61 tablets; 6-24.4 g quetiapine). All patients but one also coingested at least one other substance, and in three cases another XR drug formulation. Gastroscopic pharmacobezoar removal was achieved without complications in all patients, but was difficult due to the particular "gelatinous-sticky-pasty" consistency of the concretion. The subsequent clinical course was favorable. CONCLUSIONS The possibility of pharmacobezoar formation following a large quetiapine XR overdose should be considered, as this may influence acute patient management. Complete endoscopic pharmacobezoar removal may be a promising approach in selected cases, but further studies are needed to define its role.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the clinical applicability of a nerve stimulator–guided technique, previously described in dogs, to block the sciatic and the femoral nerves in 4 pet rabbits (Oryctolagus cuniculus) undergoing hind limb surgeries. Preanesthetic intramuscular doses of medetomidine (0.08 mg/kg), ketamine (15 mg/kg), and buprenorphine (0.03 mg/kg) were administered to the rabbit patients. The rabbits were intubated and general anesthesia was maintained using isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine at a volume of 0.05 mL/kg/nerve. Sciatic-femoral block was feasible in rabbits, and the motoric responses following electrical stimulation of both nerves were consistent with those reported in dogs after successful nerve location. Iatrogenic complications, namely nerve damage and local anesthetic toxicity, did not occur. Based on these results, the authors conclude that the sciatic-femoral nerve block described in dogs can be safely performed in rabbits. Clinical trials are required to assess the analgesic efficacy of the combined sciatic-femoral nerve block in rabbits as a part of multimodal pain management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Limited data exist on the longitudinal crestal bone changes around teeth compared with implants in partially edentulous patients. This study sought to compare the 10-year radiographic crestal bone changes (bone level [BL]) around teeth and implants in periodontally compromised (PCPs) and periodontally healthy (PHPs) patients. METHODS A total of 120 patients were evaluated for the radiographic crestal BL around dental implants and adjacent teeth at time of implant crown insertion and at the 10-year follow-up. Sixty patients had a previous history of periodontitis (PCPs), and the remaining 60 were PHPs. In each category (PCP and PHP), two different implant systems were used. The mean BL change at the implant and at the adjacent tooth at the interproximal area was calculated by subtracting the radiographic crestal BL at the time of crown cementation from the radiographic crestal BL at the 10-year follow-up. RESULTS At 10 years after therapy, the survival rate ranged from 80% to 95% for subgroups for implants, whereas it was 100% for the adjacent teeth. In all eight different patient categories evaluated, teeth demonstrated a significantly more stable radiographic BL compared with adjacent dental implants (teeth BL, 0.44 ± 0.23 mm; implant BL, 2.28 ± 0.72 mm; P <0.05). Radiographic BL changes around teeth seemed not to be influenced by the presence or absence of advanced bone loss (≥3 mm) at the adjacent implants. CONCLUSIONS Natural teeth yielded better long-term results with respect to survival rate and marginal BL changes compared with dental implants. Moreover, these findings also extend to teeth with an initial reduced periodontal attachment level, provided adequate periodontal treatment and maintenance are performed. As a consequence, the decision of tooth extraction attributable to periodontal reasons in favor of a dental implant should be carefully considered in partially edentulous patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM To assess the clinical and radiographic outcomes applying a combined resective and regenerative approach in the treatment of peri-implantitis. MATERIALS AND METHODS Subjects with implants diagnosed with peri-implantitis (i.e., pocket probing depth (PPD) ≥5 mm with concomitant bleeding on probing (BoP) and ≥2 mm of marginal bone loss or exposure of ≥1 implant thread) were treated by means of a combined approach including the application of a deproteinized bovine bone mineral and a collagen membrane in the intrabony and implantoplasty in the suprabony component of the peri-implant lesion, respectively. The soft tissues were apically repositioned allowing for a non-submerged healing. Clinical and radiographic parameters were evaluated at baseline and 12 months after treatment. RESULTS Eleven subjects with 11 implants were treated and completed the 12-month follow-up. No implant was lost yielding a 100% survival rate. At baseline, the mean PPD and mean clinical attachment level (CAL) were 8.1 ± 1.8 mm and 9.7 ± 2.5 mm, respectively. After 1 year, a mean PPD of 4.0 ± 1.3 mm and a mean CAL of 6.7 ± 2.5 mm were assessed. The differences between the baseline and the follow-up examinations were statistically significant (P = 0.001). The mucosal recession increased from 1.7 ± 1.5 at baseline to 3.0 ± 1.8 mm at the 12-month follow-up (P = 0.003). The mean% of sites with BoP+ around the selected implants decreased from 19.7 ± 40.1 at baseline to 6.1 ± 24.0 after 12 months (P = 0.032). The radiographic marginal bone level decreased from 8.0 ± 3.7 mm at baseline to 5.2 ± 2.2 mm at the 12-month follow-up (P = 0.000001). The radiographic fill of the intrabony component of the defect amounted to 93.3 ± 13.0%. CONCLUSION Within the limits of this study, a combined regenerative and resective approach for the treatment of peri-implant defects yielded positive outcomes in terms of PPD reduction and radiographic defect fill after 12 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate technical complications and failures of zirconia-based fixed prostheses supported by implants. MATERIALS AND METHODS Consecutive patients received zirconia-based single crowns (SCs) and fixed dental prostheses (FDPs) on implants in a private clinical setting between 2005 and 2010. One dentist performed all surgical and prosthetic procedures, and one master technician performed and coordinated all laboratory procedures. One-piece computer-aided design/ computer-assisted manufacture technology was used to fabricate abutments and frameworks, which were directly connected at the implant level, where possible. All patients were involved in a recall maintenance program and were finally reviewed in 2012. Data on framework fractures, chipping of veneering ceramics, and other technical complications were recorded. The primary endpoint was failure of the prostheses, ie, the need for a complete remake. A life table analysis was calculated. RESULTS A total of 289 implants supported 193 zirconia-based prostheses (120 SCs and 73 FDPs) in 127 patients (51 men, 76 women; average age: 62.5 ± 13.4 years) who were reviewed in 2012. Twenty-five (13%) prostheses were cemented on 44 zirconia abutments and 168 (87%) prostheses were screw-retained directly at the implant level. Fracture of 3 frameworks (1 SC, 2 FDPs) was recorded, and significant chipping resulted in the remake of 3 prostheses (1 SC, 2 FDPs). The 7-year cumulative survival rate was 96.4% ± 1.99%. Minor complications comprised 5 loose screws (these were retightened), small chips associated with 3 prostheses (these were polished), and dislodgement of 3 prostheses (these were recemented). Overall, 176 prostheses remained free of technical problems. CONCLUSIONS Zirconia-based prostheses screwed directly to implants are clinically successful in the short and medium term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Emergency departments may be a useful information source to describe the demographics and clinical characteristics of patients with acute cocaine-related medical problems. We therefore conducted a retrospective analysis of 165 acute, laboratory-confirmed cocaine intoxications admitted to an urban emergency department in Switzerland between January 2007 and March 2011. RESULTS A total of 165 patients with a mean age of 32 years were included. Most patients were male (73%) and unemployed (65%). Only a minority (16%) had abused cocaine alone while 84% of the patients had used at least one additional substance, most commonly ethanol (41%), opioids (38%), or cannabis (36%) as confirmed by their detection in blood samples. The most frequently reported symptoms were chest pain (21%), palpitations (19%), anxiety (36%) and restlessness (36%). Psychiatric symptoms were present in 64%. Hypertension and tachycardia were observed in 53% and 44% of the patients, respectively. Severe poisonings only occurred in patients with multiple substance intoxication (15%). Severe intoxications were non-significantly more frequent with injected drug use compared to nasal, oral, or inhalational drug use. Severe complications included acute myocardial infarction (2 cases), stroke (one case), and seizures (3 cases). Most patients (75%) were discharged home within 24 h after admission. A psychiatric evaluation in the ED was performed in 24% of the patients and 19% were referred to a psychiatric clinic. CONCLUSIONS Patients with acute cocaine intoxication often used cocaine together with ethanol and opioids and presented with sympathomimetic toxicity and/or psychiatric disorders. Severe acute toxicity was more frequent with multiple substance use. Toxicity was typically short-lasting but psychiatric evaluation and referral was often needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract BACKGROUND: The purpose of this paper is to describe the transdiaphragmatic approach to the heart for open CPR in patients that arrest at laparotomy and to present a first case series of patients that have undergone this procedure. METHODS: All patients who had undergone intraperitoneal transdiaphragmatic open CPR between January 1, 2002 and December 31, 2012 were retrieved from the operation registry at Bern University Hospital, Switzerland. Transdiaphragmatic access to the heart is initiated with a 10-cm-long anterocaudal incision in the central tendon of the diaphragm--approximately at 2 o'clock. Internal cardiac compression through the diaphragmatic incision can be performed from both sides of the patient. From the right side of the patient, cardiac massage is performed with the right hand and vice versa. RESULTS: A total of six patients were identified that suffered cardiac arrest during laparotomy with open CPR performed through the transdiaphragmatic approach. Four patients suffered cardiac arrest during orthotopic liver transplantation and two trauma patients suffered cardiac arrest during damage control laparotomy. In three patients, cardiac activity was never reestablished. However, three patients regained a perfusion heart rhythm and two of these survived to the ICU. One patient ultimately survived to discharge. CONCLUSIONS: In patients suffering cardiac arrest during laparotomy, the transdiaphragmatic approach allows for a rapid, technically easy, and almost atraumatic access to the heart, with excellent CPR performance. After this potentially life-saving procedure, pulmonary or surgical site complications are expected to occur much less compared with the conventionally performed emergency department left-sided thoracotomy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The main goals of the standard treatment for advanced symptomatic knee osteoarthritis, total knee arthroplasty (TKA), are pain reduction and restoration of knee motion.The aim of this study was to analyse the outcome of the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS), and the surgeon-based Knee Society Score (KSS) and its Knee Score (KS) and Knee Functional Score (KFS) components after (TKA) using the Journey knee prosthesis, and to assess the correlation of these scores with range of motion (ROM). METHODS In a prospective case series study between August 1st 2008 and May 31st 2011, 99 patients, all operated by a single surgeon, received Journey bicruciate stabilized total knee prostheses. The female/male ratio was 53/34, the mean patient age at surgery was 68 years (range 41-83 years), and the left/right knee ratio was 55/44. The KOOS, range of motion, and KS and KFS were obtained preoperatively and at 1-year follow-up. The pre- and postoperative levels of the outcome measures were compared using the Wilcoxon signed-rank test. Correlation between ROM and patient outcomes was analysed with the Spearman coefficient. RESULTS All KOOS subscores improved significantly. Ninety percent of patients improved by at least the minimum clinically relevant difference of 10 points in stiffness and other symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sports and recreation, and 90% in knee-related quality of life. The mean passive and active ROM improved from 122.4° (range 90-145°) and 120.4° (range 80-145°) preoperatively to 129.4° (range 90-145°) and 127.1° (range 100-145°) postoperatively. The highest correlation coefficients for ROM and KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore.There was a significant and clinically relevant improvement of KSS (preop/postop 112.2/174.5 points), and its KS (preop/postop 45.6/86.8 points) and KFS (preop/postop 66.6/87.8 points) components. CONCLUSIONS The Journey bicruciate stabilized knee prosthesis showed good 1-year postoperative results in terms of both functional and patient-based outcome. However, higher knee ROM correlates only moderately with patient-based outcome, implying that functionality afforded by the Journey bicruciate TKA is not equivalent to patient satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction. METHODS Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy. RESULTS All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris. CONCLUSIONS This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases.