998 resultados para Analytical Chemistry


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new class of chiral beta-amino disulfides was synthesized from readily available and inexpensive starting materials by a straightforward method and their abilities as ligands were examined in the enantioselective addition of diethylzinc to aldehydes. Enantiomeric excesses of up to 99% have been obtained using 0.5 mol % of the chiral catalysts.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alachlor has been widely used in agriculture all over the world. It is suggested that it may be a carcinogen and an environmental estrogen. The aim of this work was to verify the degradation the alachlor by gamma radiation. Gamma radiation from (60)Co was used to degrade the alachlor herbicide in water and methanol solution. The alachlor in water and alcohol solution in the concentration of 100 mgL(-1) was irradiated with doses of 0.25-50 kGy, at dose rate 5-6 and 2.7 kGyh(-1). High performance liquid chromatography was used as an analytical technique to determine the degradation rate of herbicide studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This technical note describes a detailed study on wax printing, a simple and inexpensive method for fabricating microfluidic devices in paper using a commercially available printer and hot plate. The printer prints patterns of solid wax on the surface of the paper, and the hot plate melts the wax so that it penetrates the full thickness of the paper. This process creates complete hydrophobic barriers in paper that define hydrophilic channels, fluid reservoirs, and reaction zones. The design of each device was based on a simple equation that accounts for the spreading of molten wax in paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multi-well plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (similar to 180 mu m), require small volumes of sample (5 mu L per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (similar to 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was aproximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eugenol is an allyl chain-substituted guaiacol in the biosynthesized phenylpropanoid compound class derived from Syzygium aromaticum L. and widely used in folk medicine. Nonetheless, its pharmacological use is limited by some problems, such as instability when exposed to light and high temperature. In order to enhance stability, the eugenol molecule was structurally modified, resulting in eugenyl acetate. The eugenyl acetate`s thermal behavior and crystal structure was then characterized by differential scanning calorimetry (DSC) and X-ray diffraction (XRD) and compared to a commercial sample.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A variety of substrates have been used for fabrication of microchips for DNA extraction, PCR amplification, and DNA fragment separation, including the more conventional glass and silicon as well as alternative polymer-based materials. Polyester represents one such polymer, and the laser-printing of toner onto polyester films has been shown to be effective for generating polyester-toner (PeT) microfluidic devices with channel depths on the order of tens of micrometers. Here, we describe a novel and simple process that allows for the production of multilayer, high aspect-ratio PeT microdevices with substantially larger channel depths. This innovative process utilizes a CO(2) laser to create the microchannel in polyester sheets containing a uniform layer of printed toner, and multilayer devices can easily be constructed by sandwiching the channel layer between uncoated cover sheets of polyester containing precut access holes. The process allows the fabrication of deep channels, with similar to 270 mu m, and we demonstrate the effectiveness of multilayer PeT microchips for dynamic solid phase extraction (dSPE) and PCR amplification. With the former, we found that (i) more than 65% of DNA from 0.6 mu L of blood was recovered, (ii) the resultant DNA was concentrated to greater than 3 ng/mu L., (which was better than other chip-based extraction methods), and (iii) the DNA recovered was compatible with downstream microchip-based PCR amplification. Illustrative of the compatibility of PeT microchips with the PCR process, the successful amplification of a 520 bp fragment of lambda-phage DNA in a conventional thermocycler is shown. The ability to handle the diverse chemistries associated with DNA purification and extraction is a testimony to the potential utility of PeT microchips beyond separations and presents a promising new disposable platform for genetic analysis that is low cost and easy to fabricate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eugenol is the main volatile compound extracted oil from clove bud, Syzygium aromaticum L., and used in traditional medicine, as a bactericide, fungicide, anesthetic, and others. Its extraction was performed using hydrodistillation which is the most common extraction technique. Its components and thermal behavior were evaluated using gas chromatography (GC) and differential scanning calorimetry (DSC), which provide a better characterization of these natural compounds. This extracted product was compared to the standard eugenol results. The GC results suggested similar to 90% eugenol was found in the total extracted oil, and some of its boiling characteristics were 270.1 A degrees C for peak temperature and 244.1 J g(-1) for the enthalpy variation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present study porcine skin and bovine pericardium were used as a source of type I collagen. Both were submitted to an alkaline treatment and mineralized by the alternate soaking method. Thermal stability and extent of mineralization have been investigated using DSC and TG. After alkaline hydrolysis there is a decrease in thermal stability but mineralization stabilizes collagen structure. Thermogravimetric data have shown that the amount of hydroxyapatite present in bovine pericardium matrix (45%) was greater than on porcine skin matrix (20%). Presence of hydroxyapatite was confirmed by EDX.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article gives an overview of our recent research into separation and detection of analytes of forensic interest. This work has been carried out in collaboration with local forensic service providers and is based on our previous studies of chemiluminescence detection, flow analysis and capillary electrophoresis as applied to process analytical chemistry for the pharmaceutical industry. Chemiluminescence has the potential to provide low limits of detection in combination with high selectivity, while capillary electrophoresis allows for rapid, highly efficient separations. Examples of recent forensic applications are presented and future directions are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A review with 98 references. The determination of the opium poppy (Papaver somniferum) alkaloids and their semi-synthetic derivatives has important applications in industrial process monitoring, clinical analysis and forensic science. Liquid-phase chemiluminescence reagents such as tris(2,2′-bipyridyl)ruthenium(II) and acidic potassium permanganate exhibit remarkable sensitivity and complementary selectivity for many P. somniferum alkaloids, which has been exploited in the development of a range of analytical procedures using flow analysis, high-performance liquid chromatography, capillary electrophoresis and microfluidic instrumentation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis covers the development of the traditionally fluorescent bis(8-quinolinol-5-sulfonic acid) magnesium (II) fluorophore as a chemiluminescent emitter. A brief description of luminescence spectroscopy and its application to analytical chemistry lays the foundation to the discussion of the results obtained herein. This includes the synthesis and identification of two so called ‘water soluble’ aryl oxamides 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino] ethylene-bis(N- methylpyridinium) trifluoromethane sulfonate (PETQ) and 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino]ethylene-bis(N-pyridinium) chloride (PETH), previously developed for the US navy as a possible emergency light source, yet the synthetic methodology were incomplete. The inconsistencies of the synthetic methods for PETQ and PETH were overcome with yields satisfactory for their preliminary analytical evaluation. The evaluation of these aryl oxamides, including 4,4’-oxalyI- bis[(trifluoromethanesulfonyl) imino]ethylene-bis(l-methyM-benzylpiperidinium) trifluoromethanesulfonate (BPTQ), 4,4’-oxalyl-bis [(trifluoromethylsulfonyl)imino] ethylene-bis(N-methylmorpholinium)trifluoromethanesulfonate (METQ) and the oxalate bis(2,4,6-trichlorophenyl) oxalate (TCPO) were performed with the peroxyoxalate chemiluminescent reaction using bis(8-quinolinol-5-sulfonic acid) magnesium (II) as the fluorophore. A univariate optimisation of this system resulted in 0,0082 mol 1-1 the detection limit of magnesium in the absence of cationic surfactants and 0.0041 mol 1-1 in their presence for the majority of these compounds. The oxamides were found to be insoluble in water with long ulrasonication periods required to dissolve the compound, with solvents such as acetonitrile preferred. The determination of other chemiluminescent metal-8HQS chelates to replace magnesium -8HQS in the peroxyoxalate were limited to Al (III), Cd (II), Ca (II), In (II) and Zn (II), unfortunately these metals all possessed poorer detection limits than those obtained using magnesium The base reaction conditions used for the flow injection system with chemiluminescent detection were transferred to an ion chromatographic configuration for the separation of magnesium from other cations on an exchange column. After a univariate and simplex optimisation of these conditions, the detection limit of magnesium was found to be 0.0411 mol 1-1 which was less than the limits that could be achieved with fluorescent detection, The further development of this reaction to incorporate the displacement of magnesium from Mg-EDTA by other metals that possessed a higher conditional stability constant than magnesium also proved to be problematic with interferences from not only EDTA but from the eluant (lactic acid) from the cation column. Using this system the detection limits of the displacing metals were found to be in the order of 10 mg 1-1 which was substantially less that what was observed when exactly the same configuration was used with fluorescent detection. The final component of the thesis entails the discussion of the background emission that results from the reaction of oxamides/oxalates with hydrogen peroxide. A detailed investigation into the reaction of TCPO and hydrogen peroxide in the presence of various additives, such as imidazole , heavy atoms and triethylamine illustrated the existence of a further intermediate in fee mechanism for this reaction. The species responsible for this emission was attributed to the degradation product 2,4,6-trichlorophenyi of TCPO, which was supported by the non-existent background present with the oxamides that do not contain this degradation product.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The research was a detailed investigation into a challenging analytical chemistry problem for the alumina industry. The successful outcomes were derived through innovative reagent chemistry and novel instrumental development. The resultant methodology and instrumentation deployed on this most demanding sample matrix is more robust, reliable and less expensive than anything currently used in this industry worldwide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The fabrication of enzyme electrodes using self-assembled monolayers (SAMs) has attracted considerable interest because of the spatial control over the enzyme immobilization. A model system of glucose oxidase covalently bound to a gold electrode modified with a SAM of 3-mercaptopropionic acid was investigated with regard to the effect of fabrication variables such as the surface topography of the underlying gold electrode, the conditions during covalent attachment of the enzyme and the buffer used. The resultant monolayer enzyme electrodes have excellent sensitivity and dynamic range which can easily be adjusted by controlling the amount of enzyme immobilized. The major drawback of such electrodes is the response which is limited by the kinetics of the enzyme rather than mass transport of substrates. Approaches to bringing such enzyme electrodes into the mass transport limiting regime by exploiting direct electron transfer between the enzyme and the electrode are outlined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple, yet very powerful technique for the spectral acquisition of an extremely thin film with enhanced absorption was explored. An infrared absorption of an extremely thin film confined between media of high refractive indices was greater than that of its bulk when the spectrum was acquired under the attenuated total reflection (ATR) condition with parallel (p) polarized radiation. The absorption enhancement was not observed under perpendicular (s) polarized radiation. Theoretical investigations indicated that the absorption enhancement was proportional to the integration of the mean square evanescent field within the film. The field integration under p-polarized radiation increased, while that under s-polarized radiation decreased as the thickness of the confined film became thinner. The maximum enhancement was observed when the film was sufficiently thinner than the penetration depth. The phenomena were experimentally investigated, and the results agreed very well with theoretical predictions.