976 resultados para ATR-FTIR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A technique is described whereby micro-ATR/FTIR imaging can be used to follow polymer degradation reactions in situ in real time. The internal reflection element (IRE) assembly is removed from the ATR objective and polymer is solvent cast directly onto the IRE surface. The polymer is then subjected to degradation conditions and molecular structural changes monitored by periodically replacing the IRE assembly back in the ATR objective and collecting spectra which can be used to construct images. This approach has the benefit that the same part of the sample is always studied, and that contact by pressure which might damage the polymer surface is not required. The technique is demonstrated using the polymer Topas which was degraded by exposure to UVC light in air.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Qualitative and quantitative measurements of biomass components dissolved in the phosphonium ionic liquids (ILs), trihexyltetradecylphosphonium chloride ([P66614]Cl) and tributylmethylphosphonium methylsulphate ([P4441]MeSO 4), are obtained using attenuated total reflectance-FTIR. Absorption bands related to cellulose, hemicelluloses, and lignin dissolution monitored in situ in biomass-IL mixtures indicate lignin dissolution in both ILs and some holocellulose dissolution in the hydrophilic [P4441]MeSO 4. The kinetics of lignin dissolution reported here indicate that while dissolution in the hydrophobic IL [P66614]Cl appears to follow an accepted mechanism of acid catalyzed -aryl ether cleavage, dissolution in the hydrophilic IL [P4441]MeSO 4 does not appear to follow this mechanism and may not be followed by condensation reactions (initiated by reactive ketones). The measurement of lignin dissolution in phosphonium ILs based on absorbance at 1510 cm 1 has demonstrated utility. When coupled with the gravimetric Klason lignin method, ATR-FTIR study of reaction mixtures can lead to a better understanding of the delignification process. © 2012 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Australia and increasingly worldwide, methamphetamine is one of the most commonly seized drugs analysed by forensic chemists. The current well-established GC/MS methods used to identify and quantify methamphetamine are lengthy, expensive processes, but often rapid analysis is requested by undercover police leading to an interest in developing this new analytical technique. Ninety six illicit drug seizures containing methamphetamine (0.1% - 78.6%) were analysed using Fourier Transform Infrared Spectroscopy with an Attenuated Total Reflectance attachment and Chemometrics. Two Partial Least Squares models were developed, one using the principal Infrared Spectroscopy peaks of methamphetamine and the other a Hierarchical Partial Least Squares model. Both of these models were refined to choose the variables that were most closely associated with the methamphetamine % vector. Both of the models were excellent, with the principal peaks in the Partial Least Squares model having Root Mean Square Error of Prediction 3.8, R2 0.9779 and lower limit of quantification 7% methamphetamine. The Hierarchical Partial Least Squares model had lower limit of quantification 0.3% methamphetamine, Root Mean Square Error of Prediction 5.2 and R2 0.9637. Such models offer rapid and effective methods for screening illicit drug samples to determine the percentage of methamphetamine they contain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to use attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and target factor analysis (TFA) to investigate the permeation of model drugs and formulation components through Carbosil® membrane and human skin. Diffusion studies of saturated solutions in 50:50 water/ethanol of methyl paraben (MP), ibuprofen (IBU) and caffeine (CF) were performed on Carbosil® membrane. The spectroscopic data were analysed by target factor analysis, and evolution profiles of the signal for each component (i.e. the drug, water, ethanol and membrane) over time were obtained. Results showed that the data were successfully deconvoluted as correlations between factors from the data and reference spectra of the components, were above 0.8 in all cases. Good reproducibility over three runs for the evolution profiles was obtained. From the evolution profiles it was observed that water diffused better through the Carbosil® membrane than ethanol, confirming the hydrophilic properties of the Carbosil® membrane used. IBU diffused slower compared with MP and CF. The evolution profile of CF was very similar to that of water, probably because of the high solubility of CF in water, indicating that both compounds are diffusing concurrently. The second part of the work involved a study of the evolution profiles of the components of a commercial topical gel containing 5% (w/w) of ibuprofen as it permeated through human skin. Although the system was much more complex, data were still successfully deconvoluted and the different components of the formulation identified except for benzyl alcohol which might be attributed to the low concentrations of benzyl alcohol used in topical formulations. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy has been used to simultaneously follow the diffusion of model drugs and solvent across polydimethylsiloxane (silicone) membrane. Three model drugs, cyanophenol (CNP), methyl nicotinate (MN) and butyl paraben (BP) were selected to cover a range of lipophilicities. Isostearyl isostearate (ISIS) was chosen as the solvent because its large molecular weight should facilitate observation of whether the drug molecules are able to diffuse through the membrane independently of the solvent. The diffusion of the three drugs and the solvent was successfully described by a Fickian model. The effects of parameters such as the absorption wavelength used to follow diffusion on the calculated diffusion coefficient were investigated. Absorption wavelength which affects the depth of penetration of the infrared radiation into the membrane did not significantly affect the calculated diffusion coefficient over the wavelength range tested. Each of the model drugs was observed to diffuse independently of the solvent across the membrane. The diffusion of a CNP-ISIS hydrogen bonded complex across the membrane was also monitored. The relative diffusion rates of the solute and solvent across the membrane can largely be accounted for by the molecular size of the permeant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The uptake and diffusion of solvents across polymer membranes is important in controlled drug delivery, effects on drug uptake into, for example, infusion bags and containers, as well as transport across protective clothing. Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) spectroscopy has been used to monitor the effects of different solvents on the diffusion of a model compound, 4-cyanophenol (CNP) across silicone membrane and on the equilibrium concentration of CNP obtained in the membrane following diffusion. ATR-FTIR spectroscopic imaging of membrane diffusion was used to gain an understanding of when the boundary conditions applied to Fick's second law, used to model the diffusion of permeants across the silicone membrane do not hold. The imaging experiments indicated that when the solvent was not taken up appreciably into the membrane, the presence of discrete solvent pools between the ATR crystal and the silicone membrane can affect the diffusion profile of the permeant. This effect is more significant if the permeant has a high solubility in the solvent. In contrast, solvents that are taken up into the membrane to a greater extent, or those where the solubility of the permeant in the vehicle is relatively low, were found to show a good fit to the diffusion model. As such these systems allow the ATR-FTIR spectroscopic approach to give mechanistic insight into how the particular solvents enhance permeation. The solubility of CNP in the solvent and the uptake of the solvent into the membrane were found to be important influences on the equilibrium concentration of the permeant obtained in the membrane following diffusion. In general, solvents which were taken up to a significant extent into the membrane and which caused the membrane to swell increased the diffusion coefficient of the permeant in the membrane though other factors such as solvent viscosity may also be important.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adsorption of water and deuterium oxide on TiO2 surfaces was investigated in the dark as well as under UV(A) irradiation using in situ ATR-FTIR spectroscopy under oxygen and oxygen free conditions. Adsorption of H2O-D2O mixtures revealed an isotopic exchange reaction occurring onto the surface of TiO2 in the dark. Under UV(A) irradiation, the amount of both OH and OD groups was found to be increased by the presence of molecular oxygen. Furthermore, the photocatalytic formation of hydroperoxide under oxygenated condition has been recorded utilizing Attenuated Total Reflection Fourier Transformed Infrared (ATR-FTIR) spectroscopy which appeared as new band at 3483 cm-1. Different possible mechanisms are discussed in terms of the source of hydroxyl groups formed and/or hydration water on the TiO2 surface for the photocatalytic reaction and photoinduced hydrophilicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The polymer conformation structure of gluten extracted from a Polish wheat cultivar, Korweta, and gluten subtractions obtained from 2 U.K. breadmaking and biscuit flour cultivars, Hereward and Riband, was investigated using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). The results showed the conformation of proteins varied between flour, hydrated flour, and hydrated gluten. The beta-sheet structure increased progressively from flour to hydrated flour and to hydrated gluten. In hydrated gluten protein fractions comprising gliadin, soluble glutenin, and gel protein, beta-sheet structure increased progressively from soluble gliadin and glutenin to gluten and gel protein; beta-sheet content was also greater in the gel protein from the breadmaking flour Hereward than the biscuit flour Riband.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Following the recent success in quantitative analysis of essential fatty acid compositions in a commercial microencapsulated fish oil (?EFO) supplement, we extended the application of portable attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopic technique and partial least square regression (PLSR) analysis for rapid determination of total protein contents-the other major component in most commercial ?EFO powders. In contrast to the traditional chromatographic methodology used in a routine amino acid analysis (AAA), the ATR-FTIR spectra of the ?EFO powder can be acquired directly from its original powder form with no requirement of any sample preparation, making the technique exceptionally fast, noninvasive, and environmentally friendly as well as being cost effective and hence eminently suitable for routine use by industry. By optimizing the spectral region of interest and number of latent factors through the developed PLSR strategy, a good linear calibration model was produced as indicated by an excellent value of coefficient of determination R2 = 0.9975, using standard ?EFO powders with total protein contents in the range of 140-450 mg/g. The prediction of the protein contents acquired from an independent validation set through the optimized PLSR model was highly accurate as evidenced through (1) a good linear fitting (R2 = 0.9759) in the plot of predicted versus reference values, which were obtained from a standard AAA method, (2) lowest root mean square error of prediction (11.64 mg/g), and (3) high residual predictive deviation (6.83) ranked in very good level of predictive quality indicating high robustness and good predictive performance of the achieved PLSR calibration model. The study therefore demonstrated the potential application of the portable ATR-FTIR technique when used together with PLSR analysis for rapid online monitoring of the two major components (i.e., oil and protein contents) in finished ?EFO powders in the actual manufacturing setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the study of the ethanol oxidation reaction of a Pt/C Etek electrocatalyst that was supported on different substrates, such as gold, glassy carbon and carbon cloth treated with PTFE. In the ethanol oxidation reaction, the activity varies with the substrate, as well as the pathways for ethanol oxidation, as studied by an ATR-FTIR in situ setup using the carbon cloth as the electrocatalyst support. The electrocatalyst Pt/C supported on gold starts acetaldehyde production from ethanol oxidation at an onset potential of 0.1 V less than that observed for the same process on Teflon-treated carbon cloth. The Pt/C supported on the carbon cloth starts its CO2 production for the same oxidation process at 0.2 V less than on the Pt/C supported on gold substrate. The differences in catalytic activity for the ethanol oxidation reaction depend not only on the electrocatalyst but also on various electrode factors, such as the substrate, the roughness of the electrode and the charge transfer resistance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Gesundheitseffekte von Aerosolpartikeln werden stark von ihren chemischen und physikalischen Eigenschaften und somit den jeweiligen Bildungsprozessen und Quellencharakteristika beeinflusst. Während die Hauptquellen der anthropogenen Partikelemissionen gut untersucht sind, stellen die spezifischen Emissionsmuster zahlreicher kleiner Aerosolquellen, welche lokal und temporär zu einer signifikanten Verschlechterung der Luftqualität beitragen können, ein Forschungsdesiderat dar.rnIn der vorliegenden Arbeit werden in kombinierten Labor- und Feldmessungen durch ein integratives Analysekonzept mittels online (HR-ToF-AMS ) und filterbasierter offline (ATR-FTIR-Spektroskopie ) Messverfahren die weitgehend unbekannten physikalischen und chemischen Eigenschaften der Emissionen besonderer anthropogener Aerosolquellen untersucht. Neben einem Fußballstadion als komplexe Mischung verschiedener Aerosolquellen wie Frittieren und Grillen, Zigarettenrauchen und Pyrotechnik werden die Emissionen durch Feuerwerkskörper, landwirtschaftliche Intensivtierhaltung (Legehennen), Tief- und Straßenbauarbeiten sowie abwasserbürtige Aerosolpartikel in die Studie mit eingebunden. Die primären Partikelemissionen der untersuchten Quellen sind vorrangig durch kleine Partikelgrößen (dp < 1 µm) und somit eine hohe Lungengängigkeit gekennzeichnet. Dagegen zeigen die Aerosolpartikel im Stall der landwirtschaftlichen Intensivtierhaltung sowie die Emissionen durch die Tiefbauarbeiten einen hohen Masseanteil von Partikeln dp > 1 µm. Der Fokus der Untersuchung liegt auf der chemischen Charakterisierung der organischen Partikelbestandteile, welche für viele Quellen die NR-PM1-Emissionen dominieren. Dabei zeigen sich wichtige quellenspezifische Unterschiede in der Zusammensetzung der organischen Aerosolfraktion. Die beim Abbrand von pyrotechnischen Gegenständen freigesetzten sowie die abwasserbürtigen Aerosolpartikel enthalten dagegen hohe relative Gehalte anorganischer Substanzen. Auch können in einigen spezifischen Emissionen Metallverbindungen in den AMS-Massenspektren nachgewiesen werden. Über die Charakterisierung der Emissionsmuster und -dynamiken hinaus werden für einige verschiedenfarbige Rauchpatronen sowie die Emissionen im Stall der Intensivtierhaltung Emissionsfaktoren bestimmt, die zur quantitativen Bilanzierung herangezogen werden können. In einem weiteren Schritt werden anhand der empirischen Daten die analytischen Limitierungen der Aerosolmassenspektrometrie wie die Interferenz organischer Fragmentionen durch (Hydrogen-)Carbonate und mögliche Auswertestrategien zur Überwindung dieser Grenzen vorgestellt und diskutiert.rnEine umfangreiche Methodenentwicklung zur Verbesserung der analytischen Aussagekraft von organischen AMS-Massenspektren zeigt, dass für bestimmte Partikeltypen einzelne Fragmentionen in den AMS-Massenspektren signifikant mit ausgewählten funktionellen Molekülgruppen der FTIR-Absorptionsspektren korrelieren. Bedingt durch ihre fehlende Spezifität ist eine allgemeingültige Interpretation von AMS-Fragmentionen als Marker für verschiedene funktionelle Gruppen nicht zulässig und häufig nur durch die Ergebnisse der komplementären FTIR-Spektroskopie möglich. Des Weiteren wurde die Verdampfung und Ionisation ausgewählter Metallverbindungen im AMS analysiert. Die Arbeit verdeutlicht, dass eine qualitative und quantitative Auswertung dieser Substanzen nicht ohne Weiteres möglich ist. Die Gründe hierfür liegen in einer fehlenden Reproduzierbarkeit des Verdampfungs- und Ionisationsprozesses aufgrund von Matrixeffekten sowie der in Abhängigkeit vorangegangener Analysen (Verdampferhistorie) in der Ionisationskammer und auf dem Verdampfer statt-findenden chemischen Reaktionen.rnDie Erkenntnisse der Arbeit erlauben eine Priorisierung der untersuchten anthropogenen Quellen nach bestimmten Messparametern und stellen für deren Partikelemissionen den Ausgangpunkt einer Risikobewertung von atmosphärischen Folgeprozessen sowie potentiell negativen Auswirkungen auf die menschliche Gesundheit dar. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fourier transform infrared (FTIR) spectroscopy was applied to determine the type of surface treatment and dose used on cork stoppers and to predict the friction between stopper and bottleneck. Agglomerated cork stoppers were finished with two different doses and using two surface treatments: P (paraffin and silicone), 15 and 25 mg/stopper, and S (only silicone), 10 and 15 mg/stopper. FTIR spectra were recorded at five points for each stopper by attenuated total reflectance (ATR). Absorbances at 1,010, 2,916, and 2,963 cm -1 were obtained in each spectrum. Discriminant analysis techniques allowed the treatment, and dose applied to each stopper to be identified from the absorbance values. 91.2% success rates were obtained from individual values and 96.0% from the mean values of each stopper. Spectrometric data also allowed treatment homogeneity to be determined on the stopper surface, and a multiple regression model was used to predict the friction index (If = Fe/Fc) (R 2 = 0.93)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the current study, the relationship between current and biomass and bio-adhesion mechanism of electrogenic biofilm on electrode were investigated using EQCM and ATR-SEIRAS linking electrochemistry. The results indicated that cellular biomass of biofilm on QCM-crystal surface showed maximum value of 6.0 μg/cm2 in initial batch and 11.5 μg/cm2 in the second batch on mature biofilm, producing a similar maximum current density of 110 μA/μg. Especially, the optimum cell biomass linking high electricity production ratio (110 μA/μg) occurred before maximum biomass coming, implying that over-growth mature biofilm is not an optimum state for enhancing power output of MFCs. On the other hand, the spectra using ATR-SEIRAS technique linking electrochemistry obviously exhibited water structure adsorption change at early biofilm formation and meanwhile the water adsorption accompanied the adsorbed bacteria and the bound cells population on the electrode increased with time. Meanwhile, the direct contact of bacteria and electrode via outer-membrane protein can be confirmed via a series spectra shift at amide I and amide II modes and water movement from negative bands displacing by adsorbed bacteria. Our study provided supplementary information about the interaction between the microbes and electrode beyond traditional electrochemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adsorption and photocatalytic degradation of acetate on TiO2 surfaces was investigated in H2O and D2O by ATR-FTIR and EPR Spectroscopy respectively. These studies were carried out in the dark and under UV(A) illumination to gain additional insights into the adsorption behaviour with the identification of paramagnetic species formed during the oxidation of acetate. Isotopic exchange during the adsorption of D2O on TiO2 surface led to different interactions between the adsorbate and OD groups. At different pH levels, several surface complexes of acetate can be formed such as monodentate, or bidentates. Under UV(A) irradiation of TiO2 aqueous suspensions, the formation of hydroxyl and methoxy radicals evidenced as the corresponding spin-adducts, were found to dominate in alkaline and acidic suspensions respectively. Two possible pathways for the oxidation of acetate have been suggested at different pH levels in solution in terms of the source of the spin adduct formed. These proposed pathways were found to be in good agreement with ATR-FTIR and EPR results.