951 resultados para 730109 Surgical methods and procedures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Candida dubliniensis is a recently described Candida species associated with oral candidosis that exhibits a high degree of phenotypic similarity to Candida albicans. However, these species show differences in levels of resistance to antimycotic agents and ability to cause infections. Therefore, accurate clinical identification of C. dubliniensis and C. albicans species is important in order to treat oral candidal infections. Phenotypic identification methods are easy-to-use procedures for routine discrimination of oral isolates in the clinical microbiology laboratory. However, C. dubliniensis may be so far underreported in clinical samples because most currently used identification methods fail to recognize this yeast. Phenotypic methods depend on growth temperature, carbon source assimilation, chlamydospore and hyphal growth production, positive or negative growth on special media and intracellular enzyme production, among others. In this review, some phenotypic methods are presented with a special emphasis on the discrimination of C. dubliniensis and C. albicans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose: The circadian rhythm of melatonin in saliva or plasma, or of the melatonin metabolite 6-sulfatoxymelatonin (a6MTs) in urine, is a defining feature of suprachiasmatic nucleus (SCN) function, the body's endogenous oscillatory pacemaker. The primary objective of this review is to ascertain the clinical benefits and limitations of current methodologies employed for detection and quantification of melatonin in biological fluids and tissues. Data Identification: A search of the English-language literature (Medline) and a systematic review of published articles were carried out. Study Selection: Articles that specified both the methodology for quantifying melatonin and indicated the clinical purpose were chosen for inclusion in the review. Data Extraction: The authors critically evaluated the methodological issues associated with various tools and techniques (e.g. standards, protocols, and procedures). Results of Data Synthesis: Melatonin measurements are useful for evaluating problems related to the onset or offset of sleep and for assessing phase delays or advances of rhythms in entrained individuals. They have also become an important tool for psychiatric diagnosis, their use being recommended for phase typing in patients suffering from sleep and mood disorders. Additionally, there has been a continuous interest in the use of melatonin as a marker for neoplasms of the pineal region. Melatonin decreases such as found with aging are or post pinealectomy can cause alterations in the sleep/wake cycle. The development of sensitive and selective methods for the precise detection of melatonin in tissues and fluids has increasingly been shown to have direct relevance for clinical decision making. Conclusions: Due to melatonin's low concentration, as well as the coexistence of numerous other compounds in the blood, the routine determination of melatonin has been an analytical challenge. The available evidence indicates however that these challenges can be overcome and consequently that evaluation of melatonin's presence and activity can be an accessible and useful tool for clinical diagnosis. © Springer-Verlag 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Every year, thousand of surgical treatments are performed in order to fix up or completely substitute, where possible, organs or tissues affected by degenerative diseases. Patients with these kind of illnesses stay long times waiting for a donor that could replace, in a short time, the damaged organ or the tissue. The lack of biological alternates, related to conventional surgical treatments as autografts, allografts, e xenografts, led the researchers belonging to different areas to collaborate to find out innovative solutions. This research brought to a new discipline able to merge molecular biology, biomaterial, engineering, biomechanics and, recently, design and architecture knowledges. This discipline is named Tissue Engineering (TE) and it represents a step forward towards the substitutive or regenerative medicine. One of the major challenge of the TE is to design and develop, using a biomimetic approach, an artificial 3D anatomy scaffold, suitable for cells adhesion that are able to proliferate and differentiate themselves as consequence of the biological and biophysical stimulus offered by the specific tissue to be replaced. Nowadays, powerful instruments allow to perform analysis day by day more accurateand defined on patients that need more precise diagnosis and treatments.Starting from patient specific information provided by TC (Computed Tomography) microCT and MRI(Magnetic Resonance Imaging), an image-based approach can be performed in order to reconstruct the site to be replaced. With the aid of the recent Additive Manufacturing techniques that allow to print tridimensional objects with sub millimetric precision, it is now possible to practice an almost complete control of the parametrical characteristics of the scaffold: this is the way to achieve a correct cellular regeneration. In this work, we focalize the attention on a branch of TE known as Bone TE, whose the bone is main subject. Bone TE combines osteoconductive and morphological aspects of the scaffold, whose main properties are pore diameter, structure porosity and interconnectivity. The realization of the ideal values of these parameters represents the main goal of this work: here we'll a create simple and interactive biomimetic design process based on 3D CAD modeling and generative algorithmsthat provide a way to control the main properties and to create a structure morphologically similar to the cancellous bone. Two different typologies of scaffold will be compared: the first is based on Triply Periodic MinimalSurface (T.P.M.S.) whose basic crystalline geometries are nowadays used for Bone TE scaffolding; the second is based on using Voronoi's diagrams and they are more often used in the design of decorations and jewellery for their capacity to decompose and tasselate a volumetric space using an heterogeneous spatial distribution (often frequent in nature). In this work, we will show how to manipulate the main properties (pore diameter, structure porosity and interconnectivity) of the design TE oriented scaffolding using the implementation of generative algorithms: "bringing back the nature to the nature".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the operator variability of different finishing and polishing techniques. After placing 120 composite restorations (Tetric EvoCeram) in plexiglassmolds, the surface of the specimens was roughened in a standardized manner. Twelve operators with different experience levels polished the specimens using the following finishing/polishing procedures: method 1 (40 ?m diamond [40D], 15 ?m diamond [15D], 42 ?m silicon carbide polisher [42S], 6 ?m silicon carbide polisher [6S] and Occlubrush [O]); method 2 (40D, 42S, 6S and O); method 3 (40D, 42S, 6S and PoGo); method 4 (40D, 42S and PoGo) and method 5 (40D, 42S and O). The mean surface roughness (Ra) was measured with a profilometer. Differences between the methods were analyzed with non-parametric ANOVA and pairwise Wilcoxon signed rank tests (?=0.05). All the restorations were qualitatively assessed using SEM. Methods 3 and 4 showed the best polishing results and method 5 demonstrated the poorest. Method 5 was also most dependent on the skills of the operator. Except for method 5, all of the tested procedures reached a clinically acceptable surface polish of Ra?0.2 ?m. Polishing procedures can be simplified without increasing variability between operators and without jeopardizing polishing results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vascular surgeons perform numerous highly sophisticated and delicate procedures. Due to restrictions in training time and the advent of endovascular techniques, new concepts including alternative environments for training and assessment of surgical skills are required. Over the past decade, training on simulators and synthetic models has become more sophisticated and lifelike. This study was designed to evaluate the impact of a 3-day intense training course in open vascular surgery on both specific and global vascular surgical skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess perioperative outcomes and blood pressure (BP) responses to an implantable carotid sinus baroreflex activating system being investigated for the treatment of resistant hypertension. METHODS: We report on the first seventeen patients enrolled in a multicenter study. Bilateral perivascular carotid sinus electrodes (CSL) and a pulse generator (IPG) are permanently implanted. Optimal placement of the CSL is determined by intraoperative BP responses to test activations. Acute BP responses were tested postoperatively and during the first four months of follow-up. RESULTS: Prior to implant, BP was 189.6+/-27.5/110.7+/-15.3 mmHg despite stable therapy (5.2+/-1.8 antihypertensive drugs). The mean procedure time was 202+/-43 minutes. No perioperative strokes or deaths occurred. System tests performed 1 or up to 3 days postoperatively resulted in significant (all p < or = 0.0001) mean maximum reduction, with standard deviations and 95% confidence limits for systolic BP, diastolic BP and heart rate of 28+/-22 (17, 39) mmHg, 16+/-11 (10, 22) mmHg and 8+/-4 (6, 11) BPM, respectively. Repeated testing during 3 months of therapeutic electrical activation demonstrated a durable response. CONCLUSIONS: These preliminary data suggest an acceptable safety of the procedure with a low rate of adverse events and support further clinical development of baroreflex activation as a new concept to treat resistant hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY BACKGROUND/OBJECTIVES Orthodontic management of maxillary canine impaction (MCI), including forced eruption, may result in significant root resorption; however, the association between MCI and orthodontically induced root resorption (OIRR) is not yet sufficiently established. The purpose of this retrospective cohort study was to comparatively evaluate the severity of OIRR of maxillary incisors in orthodontically treated patients with MCI. Additionally, impaction characteristics were associated with OIRR severity. SUBJECTS AND METHODS The sample comprised 48 patients undergoing fixed-appliance treatment-24 with unilateral/bilateral MCI and 24 matched controls without impaction. OIRR was calculated using pre- and post-operative panoramic tomograms. The orientation of eruption path, height, sector location, and follicle/tooth ratio of the impacted canine were also recorded. Mann-Whitney U-test and univariate and multivariate linear mixed models were used to test for the associations of interest. RESULTS Maxillary central left incisor underwent more OIRR in the impaction group (mean difference = 0.58mm, P = 0.04). Overall, the impaction group had 0.38mm more OIRR compared to the control (95% confidence interval, CI: 0.03, 0.74; P = 0.04). However, multivariate analysis demonstrated no difference in the amount of OIRR between impaction and non-impaction groups overall. A positive association between OIRR and initial root length was observed (95% CI: 0.08, 0.27; P < 0.001). The severity of canine impaction was not found to be a significant predictor of OIRR. LIMITATIONS This study was a retrospective study and used panoramic tomograms for OIRR measurements. CONCLUSIONS This study indicates that MCI is a weak OIRR predictor. Interpretation of the results needs caution due to the observational nature of the present study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Training and assessment paradigms for laparoscopic surgical skills are evolving from traditional mentor–trainee tutorship towards structured, more objective and safer programs. Accreditation of surgeons requires reaching a consensus on metrics and tasks used to assess surgeons’ psychomotor skills. Ongoing development of tracking systems and software solutions has allowed for the expansion of novel training and assessment means in laparoscopy. The current challenge is to adapt and include these systems within training programs, and to exploit their possibilities for evaluation purposes. This paper describes the state of the art in research on measuring and assessing psychomotor laparoscopic skills. It gives an overview on tracking systems as well as on metrics and advanced statistical and machine learning techniques employed for evaluation purposes. The later ones have a potential to be used as an aid in deciding on the surgical competence level, which is an important aspect when accreditation of the surgeons in particular, and patient safety in general, are considered. The prospective of these methods and tools make them complementary means for surgical assessment of motor skills, especially in the early stages of training. Successful examples such as the Fundamentals of Laparoscopic Surgery should help drive a paradigm change to structured curricula based on objective parameters. These may improve the accreditation of new surgeons, as well as optimize their already overloaded training schedules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New digital artifacts are emerging in data-intensive science. For example, scientific workflows are executable descriptions of scientific procedures that define the sequence of computational steps in an automated data analysis, supporting reproducible research and the sharing and replication of best-practice and know-how through reuse. Workflows are specified at design time and interpreted through their execution in a variety of situations, environments, and domains. Hence it is essential to preserve both their static and dynamic aspects, along with the research context in which they are used. To achieve this, we propose the use of multidimensional digital objects (Research Objects) that aggregate the resources used and/or produced in scientific investigations, including workflow models, provenance of their executions, and links to the relevant associated resources, along with the provision of technological support for their preservation and efficient retrieval and reuse. In this direction, we specified a software architecture for the design and implementation of a Research Object preservation system, and realized this architecture with a set of services and clients, drawing together practices in digital libraries, preservation systems, workflow management, social networking and Semantic Web technologies. In this paper, we describe the backbone system of this realization, a digital library system built on top of dLibra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Software for video-based multi-point frequency measuring and mapping: http://hdl.handle.net/10045/53429

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Safety Bureau, Washington, D.C.