999 resultados para 110000 MEDICAL AND HEALTH SCIENCES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine whether primary care management of chronic heart failure (CHF) differed between rural and urban areas in Australia. Design: A cross-sectional survey stratified by Rural, Remote and Metropolitan Areas (RRMA) classification. The primary source of data was the Cardiac Awareness Survey and Evaluation (CASE) study. Setting: Secondary analysis of data obtained from 341 Australian general practitioners and 23 845 adults aged 60 years or more in 1998. Main outcome measures: CHF determined by criteria recommended by the World Health Organization, diagnostic practices, use of pharmacotherapy, and CHF-related hospital admissions in the 12 months before the study. Results: There was a significantly higher prevalence of CHF among general practice patients in large and small rural towns (16.1%) compared with capital city and metropolitan areas (12.4%) (P < 0.001). Echocardiography was used less often for diagnosis in rural towns compared with metropolitan areas (52.0% v 67.3%, P < 0.001). Rates of specialist referral were also significantly lower in rural towns than in metropolitan areas (59.1% v 69.6%, P < 0.001), as were prescribing rates of angiotensin-converting enzyme inhibitors (51.4% v 60.1%, P < 0.001). There was no geographical variation in prescribing rates of β-blockers (12.6% [rural] v 11.8% [metropolitan], P = 0.32). Overall, few survey participants received recommended “evidence-based practice” diagnosis and management for CHF (metropolitan, 4.6%; rural, 3.9%; and remote areas, 3.7%). Conclusions: This study found a higher prevalence of CHF, and significantly lower use of recommended diagnostic methods and pharmacological treatment among patients in rural areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In rats immunized systemically with tetanus toxoid the concentration of specific anti-tetanus-toxoid-specific IgG in fluid from the rete testis and cauda epididymidis were respectively 0.6% and 1.4% the concentration in blood serum. The extratesticular duct system reabsorbed 97% of the IgG and 99% of the fluid leaving the rete, but estradiol administration affected the site of reabsorption. In untreated rats, the ductuli efferentes reabsorbed 94% of the IgG and 96% of the fluid leaving the rete, whereas estradiol-treated rats reabsorbed 83% of the IgG and 86% of the fluid, and the ductus epididymidis fully compensated for these different effects of estradiol on the ductuli efferentes. The concentrations of IgG in secretions of the seminal vesicles and prostate gland were lower (0.1% and 0.3% respectively of the titers in blood serum) than in fluids from the extratesticular ducts, and were not affected by the administration of estradiol. RT-PCR showed that Fcgrt (neonatal Fc receptor, also known as FcRn) is expressed in the reproductive ducts, where IgG is probably transported across epithelium, being particularly strong in the ductuli efferentes (where most IgG was reabsorbed) and distal caput epididymidis. It is concluded that IgG enters the rete testis and is concentrated only 2.5-fold along the extratesticular duct system, unlike spermatozoa, which are concentrated 95-fold. Further, the ductus epididymidis can recognize and compensate for changes in function of the ductuli efferentes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine whether remote monitoring (structured telephone support or telemonitoring) without regular clinic or home visits improves outcomes for patients with chronic heart failure. Data sources: 15 electronic databases, hand searches of previous studies, and contact with authors and experts. Data extraction: Two investigators independently screened the results. Review methods: Published randomised controlled trials comparing remote monitoring programmes with usual care in patients with chronic heart failure managed within the community. Results: 14 randomised controlled trials (4264 patients) of remote monitoring met the inclusion criteria: four evaluated telemonitoring, nine evaluated structured telephone support, and one evaluated both. Remote monitoring programmes reduced the rates of admission to hospital for chronic heart failure by 21% (95% confidence interval 11% to 31%) and all cause mortality by 20% (8% to 31%); of the six trials evaluating health related quality of life three reported significant benefits with remote monitoring, and of the four studies examining healthcare costs with structured telephone support three reported reduced cost and one no effect. Conclusion: Programmes for chronic heart failure that include remote monitoring have a positive effect on clinical outcomes in community dwelling patients with chronic heart failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Although the potential to reduce hospitalisation and mortality in chronic heart failure (CHF) is well reported, the feasibility of receiving healthcare by structured telephone support or telemonitoring is not. Aims: To determine; adherence, adaptation and acceptability to a national nurse-coordinated telephone-monitoring CHF management strategy. The Chronic Heart Failure Assistance by Telephone Study (CHAT). Methods: Triangulation of descriptive statistics, feedback surveys and qualitative analysis of clinical notes. Cohort comprised of standard care plus intervention (SC + I) participants who completed the first year of the study. Results: 30 GPs (70% rural) randomised to SC + I recruited 79 eligible participants, of whom 60 (76%) completed the full 12 month follow-up period. During this time 3619 calls were made into the CHAT system (mean 45.81 SD ± 79.26, range 0-369), Overall there was an adherence to the study protocol of 65.8% (95% CI 0.54-0.75; p = 0.001) however, of the 60 participants who completed the 12 month follow-up period the adherence was significantly higher at 92.3% (95% CI 0.82-0.97, p ≤ 0.001). Only 3% of this elderly group (mean age 74.7 ±9.3 years) were unable to learn or competently use the technology. Participants rated CHAT with a total acceptability rate of 76.45%. Conclusion: This study shows that elderly CHF patients can adapt quickly, find telephone-monitoring an acceptable part of their healthcare routine, and are able to maintain good adherence for a least 12 months. © 2007.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in vitro and in vivo degradation properties of poly(lactic-co-glycolic acid) (PLGA) scaffolds produced by two different technologies - thermally induced phase separation (TIPS), and solvent casting and particulate leaching (SCPL) were compared. Over 6 weeks, in vitro degradation produced changes in SCPL scaffold dimension, mass, internal architecture and mechanical properties. TIPS scaffolds produced far less changes in these parameters providing significant advantages over SCPL. In vivo results were based on a microsurgically created arteriovenous (AV) loop sandwiched between two TIPS scaffolds placed in a polycarbonate chamber under rat groin skin. Histologically, a predominant foreign body giant cell response and reduced vascularity was evident in tissue ingrowth between 2 and 8 weeks in TIPS scaffolds. Tissue death occurred at 8 weeks in the smallest pores. Morphometric comparison of TIPS and SCPL scaffolds indicated slightly better tissue ingrowth but greater loss of scaffold structure in SCPL scaffolds. Although advantageous in vitro, large surface area:volume ratios and varying pore sizes in PLGA TIPS scaffolds mean that effective in vivo (AV loop) utilization will only be achieved if the foreign body response can be significantly reduced so as to allow successful vascularisation, and hence sustained tissue growth, in pores less than 300 μm. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To explore the role of the neighborhood environment in supporting walking Design: Cross sectional study of 10,286 residents of 200 neighborhoods. Participants were selected using a stratified two-stage cluster design. Data were collected by mail survey (68.5% response rate). Setting: The Brisbane City Local Government Area, Australia, 2007. Subjects: Brisbane residents aged 40 to 65 years. Measures Environmental: street connectivity, residential density, hilliness, tree coverage, bikeways, and street lights within a one kilometer circular buffer from each resident’s home; and network distance to nearest river or coast, public transport, shop, and park. Walking: minutes in the previous week categorized as < 30 minutes, ≥ 30 < 90 minutes, ≥ 90 < 150 minutes, ≥ 150 < 300 minutes, and ≥ 300 minutes. Analysis: The association between each neighborhood characteristic and walking was examined using multilevel multinomial logistic regression and the model parameters were estimated using Markov chain Monte Carlo simulation. Results: After adjustment for individual factors, the likelihood of walking for more than 300 minutes (relative to <30 minutes) was highest in areas with the most connectivity (OR=1.93, 99% CI 1.32-2.80), the greatest residential density (OR=1.47, 99% CI 1.02-2.12), the least tree coverage (OR=1.69, 99% CI 1.13-2.51), the most bikeways (OR=1.60, 99% CI 1.16-2.21), and the most street lights (OR=1.50, 99% CI 1.07-2.11). The likelihood of walking for more than 300 minutes was also higher among those who lived closest to a river or the coast (OR=2.06, 99% CI 1.41-3.02). Conclusion: The likelihood of meeting (and exceeding) physical activity recommendations on the basis of walking was higher in neighborhoods with greater street connectivity and residential density, more street lights and bikeways, closer proximity to waterways, and less tree coverage. Interventions targeting these neighborhood characteristics may lead to improved environmental quality as well as lower rates of overweight and obesity and associated chromic disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seat pressure is known as a major factor of seat comfort in vehicles. In passenger vehicles, there is lacking research into the seat comfort of rear seat occupants. As accurate seat pressure measurement requires significant effort, simulation of seat pressure is evolving as a preferred method. However, analytic methods are based on complex finite element modeling and therefore are time consuming and involve high investment. Based on accurate anthropometric measurements of 64 male subjects and outboard rear seat pressure measurements in three different passenger vehicles, this study investigates if a set of parameters derived from seat pressure mapping are sensitive enough to differentiate between different seats and whether they correlate with anthropometry in linear models. In addition to the pressure map analysis, H-Points were measured with a coordinate measurement system based on palpated body landmarks and the range of H-Point locations in the three seats is provided. It was found that for the cushion, cushion contact area and cushion front area/force could be modeled by subject anthropometry,while only seatback contact area could be modeled based on anthropometry for all three vehicles. Major differences were found between the vehicles for other parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anthropometry has long been used for a range of ergonomic applications & product design. Although products are often designed for specific cohorts, anthropometric data are typically sourced from large scale surveys representative of the general population. Additionally, few data are available for emerging markets like China and India. This study measured 80 Chinese males that were representative of a specific cohort targeted for the design of a new product. Thirteen anthropometric measurements were recorded and compared to two large databases that represented a general population, a Chinese database and a Western database. Substantial differences were identified between the Chinese males measured in this study and both databases. The subjects were substantially taller, heavier and broader than subjects in the older Chinese database. However, they were still substantially smaller, lighter and thinner than Western males. Data from current Western anthropometric surveys are unlikely to accurately represent the target population for product designers and manufacturers in emerging markets like China.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kinematic models are commonly used to quantify foot and ankle kinematics, yet no marker sets or models have been proven reliable or accurate when wearing shoes. Further, the minimal detectable difference of a developed model is often not reported. We present a kinematic model that is reliable, accurate and sensitive to describe the kinematics of the foot–shoe complex and lower leg during walking gait. In order to achieve this, a new marker set was established, consisting of 25 markers applied on the shoe and skin surface, which informed a four segment kinematic model of the foot–shoe complex and lower leg. Three independent experiments were conducted to determine the reliability, accuracy and minimal detectable difference of the marker set and model. Inter-rater reliability of marker placement on the shoe was proven to be good to excellent (ICC = 0.75–0.98) indicating that markers could be applied reliably between raters. Intra-rater reliability was better for the experienced rater (ICC = 0.68–0.99) than the inexperienced rater (ICC = 0.38–0.97). The accuracy of marker placement along each axis was <6.7 mm for all markers studied. Minimal detectable difference (MDD90) thresholds were defined for each joint; tibiocalcaneal joint – MDD90 = 2.17–9.36°, tarsometatarsal joint – MDD90 = 1.03–9.29° and the metatarsophalangeal joint – MDD90 = 1.75–9.12°. These thresholds proposed are specific for the description of shod motion, and can be used in future research designed at comparing between different footwear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Battery powered bed movers are becoming increasingly common within the hospital setting. The use of powered bed movers is believed to result in reduced physical efforts required by health care workers, which may be associated with a decreased risk of occupation related injuries. However, little work has been conducted assessing how powered bed movers impact on levels of physiological strain and muscle activation for the user. The muscular efforts associated with moving hospital beds using three different methods; manual pushing, StaminaLift Bed Mover (SBM) and Gzunda Bed Mover (GBM)were measured on six male subjects. Fourteen muscles were assessed moving a weighted hospital bed along a standardized route in an Australian hospital environment. Trunk inclination and upper spine acceleration were also quantified. Powered bed movers exhibited significantly lower muscle activation levels than manual pushing for the majority of muscles. When using the SBM, users adopted a more upright posture which was maintained while performing different tasks (e.g. turning a corner, entering a lift), while trunk inclination varied considerably for manual pushing and the GBM. The reduction in lower back muscular activation levels and the load reducing effect of a more upright posture may result in lower incidence of lower back injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple marker sets and models are currently available for assessing foot and ankle kinematics in gait. Despite the presence of such a wide variety of models, the reporting of methodological designs remains inconsistent and lacks clearly defined standards. This review highlights the variability found when reporting biomechanical model parameters, methodological design, and model reliability. Further, the review clearly demonstrates the need for a consensus of what methodological considerations to report in manuscripts, which focus on the topic of foot and ankle biomechanics. We propose five minimum reporting standards, that we believe will ensure the transparency of methods and begin to allow the community to move towards standard modelling practice. The strict adherence to these standards should ultimately improve the interpretation and clinical useability of foot and ankle marker sets and their corresponding models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complex interaction of the bones of the foot has been explored in detail in recent years, which has led to the acknowledgement in the biomechanics community that the foot can no longer be considered as a single rigid segment. With the advance of motion analysis technology it has become possible to quantify the biomechanics of simplified units or segments that make up the foot. Advances in technology coupled with reducing hardware prices has resulted in the uptake of more advanced tools available for clinical gait analysis. The increased use of these techniques in clinical practice requires defined standards for modelling and reporting of foot and ankle kinematics. This systematic review aims to provide a critical appraisal of commonly used foot and ankle marker sets designed to assess kinematics and thus provide a theoretical background for the development of modelling standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nursing personnel are consistently identified as one of the occupational groups most at risk of work-related musculoskeletal disorders. During the moving and handling of bariatric patients, the weight of the patient combined with atypical body mass contributes to a significant risk of injury to the care provider and patient. This is further compounded by the shape, mobility and co-operation of the patient. The aim of this study was determine user experiences and design requirements for mobile hoists with bariatric patients. Structured interviews were conducted with six experienced injury management staff from the Manual Task Services department of three hospitals in Adelaide, South Australia. All staff had experience in patient handling, the use of patient handling equipment and the provision of patient handling training. A series of open-ended questions were structured around five main themes: 1) patient factors; 2) building/vehicle space and design; 3) equipment and furniture; 4) communication; and 5) staff issues. Questions focussed on the use of mobile hoists for lifting and transferring bariatric patients. Interviews were supplemented with a walk-through of the hospital to view the types of mobile hoists used, and the location and storage of equipment. Across the three hospitals there were differing classification systems to define bariatric patients. Ensuring patient dignity, respect and privacy were viewed as important in the management and rehabilitation of bariatric patients. Storage and space constraints were considered factors restricting the use of mobile floor hoists, with ceiling hoists being the preferred method for patient transfers. When using mobile floor hoists, the forces required to push, pull and manoeuvre, as well as sudden unstable movements of the hoist were considered important risks factors giving rise to a risk of injury to the care provider. Record keeping and purchasing policies appeared to inhibit the effective use of patient handling equipment. The moving and handling of bariatric patients presents complex and challenging issues. A co-ordinated and collaborative approach for moving and handling bariatric patients is needed across the range of care providers. Designers must consider both user and patient requirements.