976 resultados para Dentistry, Oral Surgery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To assess the prevalence of primary headaches (HA) in adults with temporomandibular disorders (TMD) who were assessed in a specialty orofacial pain clinic, as well as in controls without TMD. Methods: The sample consisted of 158 individuals with TMD seen at a university-based specialty clinic, as well as 68 controls. The Research Diagnostic Criteria for TMD were used to diagnose the TMD patients. HAs were assessed using a structured interview and classified according to the Second Edition of the International Classification for Headache Disorders. Data were analyzed by chi-square tests with a significance level of 5% and odds ratio (OR) tests with a 95% confidence interval (CI). Results: HAs occurred in 45.6% of the control group (30.9% had migraine and 14.7% had tension-type headache [TTH]) and in 85.5% of individuals with TMD. Among individuals with TMD, migraine was the most prevalent primary HA (55.3%), followed by TTH (30.2%); 14.5% had no HA. In contrast to controls, the odds ratio (OR) for HA in those with TMD was 7.05 (95% confidence interval [CI] = 3.65-13.61; P = .000), for migraine, the OR was 2.76 (95% CI = 1.50-5.06; P = .001), and for TTH, the OR was 2.51 (95% CI = 1.18-5.35; P = .014). Myofascial pain/arthralgia was the most common TMD diagnosis (53.2%). The presence of HA or specific HAs was not associated with the time since the onset of TMD (P = .714). However, migraine frequency was positively associated with TMD pain severity (P = .000). Conclusion: TMD was associated with increased primary HA prevalence rates. Migraine was the most common primary HA diagnosis in individuals with TMD. J OROFAC PAIN 2010;24:287-292

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate, through histomorphometric analysis, the effect that different loading times would have on the bone response around implants. Materials and Methods: Three Replace Select implants were placed on each side of the mandible in eight dogs (n = 48 implants). One pair of implants was selected for an immediate loading protocol (IL). After 7 days, the second pair of implants received prostheses for an early loading protocol (EL). Fourteen days after implant placement, the third pair of implants received prostheses for advanced early loading (AEL). Following 12 weeks of prosthetics, counted following the positioning of the metallic crowns for the AEL group, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters were evaluated through analysis of variance: bone-to-implant contact, bone density, and crestal bone loss. Results: The mean percentage of bone-to-implant contact for IL was 77.9% +/- 1.71%, for EL it was 79.25% +/- 2.11%, and for AEL it was 79.42% +/- 1.49%. The mean percentage of bone density for IL was 69.97% +/- 3.81%, for EL it was 69.23% +/- 5.68%, and for AEL it was 69.19% +/- 2.90%. Mean crestal bone loss was 1.57 +/- 0.22 mm for IL, 1.23 +/- 0.19 mm for EL, and 1.17 +/- 0.32 mm for AEL. There was no statistical difference for any of the parameters evaluated (P > .05). Conclusion: Different early loading times did not seem to significantly affect the bone response around dental implants. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:473-481

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study investigated the inhibition of the antimicrobial activity of sodium hypochlorite (NaOCl) by bovine serum albumin (BSA). The killing of Enterococcus faecalis, Candida albicans, Staphylococcus epidermidis, and Escherichia coil by NaOCl in concentrations from 2% to 0.03% was measured in the presence of BSA in concentrations between 6.7% and 0.1%. Methods: NaOCl, BSA, and microorganism suspensions were mixed, and, after 30 seconds, 6 minutes, and 30 minutes, samples were taken and NaOCl was inactivated by 5% sodium thiosulphate. The microbes were incubated in tryptic soy broth broth for up to 7 days for the detection of growth. Results: All microorganisms were killed within 30 seconds by 0.03% NaOCl when BSA was not present. High concentrations of BSA significantly reduced the antimicrobial activity of NaOCl against the four species. Conclusions: The inhibition of sodium hypochlorite by BSA was directly dependent on their quantitative relationships. The result partly explains the poorer performance in vivo of NaOCl as compared to in vitro experiments. (J Endod 2010;36:268-271)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This retrospective study evaluated the epidemiology, treatment and complications of mandibular fracture associated, or not associated, with other facial fractures, when the influence of the surgeon`s skill and preference for ally rigid internal fixation (RIF) system devices was minimized. The files of 700 patients with facial trauma were available, and 126 files were chosen for review. Data were collected regarding gender, age, race, date of trauma, date of surgery, addictions, etiology, signs and symptoms, fracture area, complications, treatment performed, date of hospital discharge.. and medication. 126 patients suffered mandibular fractures associated, or not, with other maxillofacial fractures, and a total of 201 mandibular fractures were found. The incidence of mandibular fractures was more prevalent in males, in Caucasians and during the third decade of life. The most common site was the condyle, followed by the mandibular body. The therapy applied was effective in handling this type of fracture and the Success rates were comparable with other published data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Physical and bioceramic incorporation surface treatments at the nanometer scale showed higher means of bone-to-implant contact (BIC) and torque values compared with surface topography at the micrometer scale; however, the literature concerning the effect of nanometer scale parameters is sparse. Purpose: The aim of this study was to evaluate the influence of two different implant surfaces on the percentage bone-to-implant contact (BIC%) and bone osteocyte density in the human posterior maxilla after 2 months of unloaded healing. Materials and Methods: The implants utilized presented dual acid-etched (DAE) surface and a bioceramic molecular impregnated treatment (Ossean(R), Intra-Lock International, Boca Raton, FL, USA) serving as control and test, respectively. Ten subjects (59 1 9 years of age) received two implants (one of each surface) during conventional implant surgery in the posterior maxilla. After the non-loaded period of 2 months, the implants and the surrounding tissue were removed by means of a trephine and were non-decalcified processed for ground sectioning and analysis of BIC%, bone density in threaded area (BA%), and osteocyte index (Oi). Results: Two DAE implants were found to be clinically unstable at time of retrieval. Histometric evaluation showed significantly higher BIC% and Oi for the test compared to the control surface (p < .05), and that BA% was not significantly different between groups. Wilcoxon matched pairs test was used to compare the differences of histomorphometric variables between implant surfaces. The significance test was conducted at a 5% level of significance. Conclusion: The histological data suggest that the bioceramic molecular impregnated surface-treated implants positively modulated bone healing at early implantation times compared to the DAE surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Titanium (Ti) is widely proven to enhance bone contact and growth on its surface. It is expected that bone defects could benefit from Ti to promote healing and to increase strength of the implanted area. Purpose: The present study aimed at comparing the potential of porous Ti sponge rods with synthetic hydroxyapatite (HA) for the healing of bone defects in a canine model. Material and Methods: Six mongrel dogs were submitted to three trephined osteotomies of 6.0 x 4.0 mm in one humerus and after 2 months another three osteotomies were performed in the contralateral humerus. A total of 36 defects were randomly filled either with Ti foam, particulate HA, or coagulum (control). The six animals were killed 4 months after the first surgery for histological and histometrical analysis. Results: The Ti-foam surface was frequently found in intimate contact with new bone especially at the defect walls. Control sites showed higher amounts of newly formed bone at 2 months - Ti (p = 0.000) and HA (p = 0.009) - and 4 months when compared with Ti (p = 0.001). Differently from HA, the Ti foam was densely distributed across the defect area which rendered less space for bone growth in the latter`s sites. The use of Ti foams or HA resulted in similar amounts of bone formation in both time intervals. Nevertheless, the presence of a Ti-foam rod preserved defect`s marginal bone height as compared with control groups. Also, the Ti-foam group showed a more mature bone pattern at 4 months than HA sites. Conclusion: The Ti foam exhibited good biocompatibility, and its application resulted in improved maintenance of bone height compared with control sites. The Ti foam in a rod design exhibited bone ingrowth properties suitable for further exploration in other experimental situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This clinical study aimed to evaluate initial, 4-months, and 1-year stability of immediately loaded dental implants inserted according to a protocol of lower rehabilitation with prefabricated bars. Materials and Methods: The sample was composed of 11 edentulous patients. In each patient, 4 interforaminal implants were inserted. Immediately after implant installation, resonance frequency analysis (RFA) for each fixation was registered as well as after 4 months and 1 year with the prosthetic bar removed as it is a screwed system. Results: The clinical implant survival rate was 100%. The RFA showed an increase in stability after 4 months from 64.09 +/- 648 to 64.31 +/- 4.96 and I year, 67.11 +/- 4.37. The analysis of variance showed a statistically significant result (P = 0.015) among implant stability quotient values for the different periods evaluated. Tukey test results showed statistically significant differences between 1-year results and the initial periods but there was no statistically significant difference between initial and 4-month results (P > 0.05). Conclusion: These preliminary 1-year results indicate that immediate loading of mandibular dental implants using the studied prefabricated bars protocol is a reliable treatment as it is in accordance with the results described in the literature for other similar techniques. (Implant Dent 2009; 18:530-538)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives Little information is available on the molecular events that occur during graft incorporation over time. The calvarial bone (Cb) grafts have been reported to produce greater responses compared with other donor regions in maxillofacial reconstructions, but the scientific evidences for this are still lacking. The objectives of this study are (1) to study the morphological pattern of Cb onlay bone grafts and compare them with the biological events through immunohistochemical responses and (2) to establish the effects of perforations in maintaining the volume and bone density of the receptor bed. Material and methods Sixty New Zealand White rabbits were submitted to Cb onlay bone grafts on the mandible. In 30 rabbits, the receptor bed was perforated (perforated group), while for the remaining animals the bed was kept intact (non-perforated group). Six animals from each group were sacrificed at 5, 7, 10, 20 and 60 days after surgery. Histological sections from the grafted area were prepared for immunohistochemical and histological analyses. Immuno-labeling was found for proteins Osteoprotegerin (OPG), receptor activator of nuclear factor-kappa beta ligand (RANKL), alkaline phosphatase (ALP), osteopontin (OPN), vascular endothelial growth factor (VEGF), tartrate-resistant acid phosphatase (TRAP), Type I collagen (COL I) and osteocalcin (OC). The tomography examination [computerized tomography (CT) scan] was conducted just after surgery and at the sacrifice. Results The histological findings revealed that the perforations contributed to higher bone deposition during the initial stages at the graft-receptor bed interface, accelerating the graft incorporation process. The results of the CT scan showed lower resorption for the perforated group (P < 0.05), and both groups showed high bone density rates at 60 days. This set of evidences is corroborated by the immunohistochemical outcomes indicating that proteins associated with revascularization and osteogenesis (VEGF, OPN, TRAP and ALP) were found in higher levels in the perforated group. Conclusions These findings indicate that the bone volume of calvarial grafts is better maintained when the receptor bed is perforated, probably resulting from more effective graft revascularization and greater bone deposition. The process of bone resorption peaked between 20 and 60 days post-operatively in both groups although significantly less in the perforated group. To cite this article:Pedrosa Jr WF, Okamoto R, Faria PEP, Arnez MFM, Xavier SP, Salata LA. Immunohistochemical, tomographic and histological study on onlay bone grafts remodeling. Part II: calvarial bone.Clin. Oral Impl. Res. 20, 2009; 1254-1264.doi: 10.1111/j.1600-0501.2009.01747.x.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Limited studies have demonstrated that low intensity laser therapy (LILT) may have a therapeutic effect on the treatment of myofascial pain syndrome (MPS). Sixty (60) patients with MPS and having one active trigger point in the anterior masseter and anterior temporal muscles were selected and assigned randomly to six groups (n=10): Groups I to III were treated with GaAIAS (780 nm) laser, applied in continuous mode and in a meticulous way, twice a week, for four weeks. Energy was set to 25 J/cm(2), 60 J/cm2 and 105 J/cm2, respectively. Groups IV to VI were treated with placebo applications, simulating the same parameters as the treated groups. Pain scores were assessed just before, then immediately after the fourth application, immediately after the eighth application, at 15 days and one month following treatment. A significant pain reduction was observed over time (p<0.001). The analgesic effect of the LILT was similar to the placebo groups. Using the parameters described in this experiment, LILT was effective in reducing pain experienced by patients with myofascial pain syndrome. Thus, it was not possible to establish a treatment protocol. Analyzing the analgesic effect of LILT suggests it as a possible treatment of MPS and may help to establish a clinical protocol for this therapeutic modality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to investigate the neuromuscular changes associated with the orthodontic post-treatment using surface electromyography. One hundred (100) young, healthy adults without signs and symptoms of temporomandibular dysfunction (TMD) were divided into two groups: 60 subjects who were undergoing orthodontic intervention (Ortho Group) and 40 subjects who had no orthodontic intervention (Control Group), aged 18-25 years. EMG activity of masseter and temporalis anterior muscle was recorded during two different tests: 1. maximum voluntary clench (MVC) with cotton rolls; and 2. MVC in intercuspal position. In all subjects, both tests were performed with symmetric muscular patterns (more than 85%) and with insignificant latero-deviating of the mandible (lower than 10%). There are no statistically significant differences between the subjects of both groups evaluated. Both groups showed medium index values calculated according to the normal standards established previously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. This study evaluated histopathologically the response of pulp and periradicular tissues after pulp capping with an all-in-one self-etching adhesive system in dogs` teeth. Study design. Forty teeth of 4 dogs were assigned to 3 groups according to the pulp capping material: G1 (n = 20): self-etching adhesive system; G2 (n = 10): Ca(OH)(2); G3 (n = 10): zinc oxide-eugenol. The animals were killed 7 and 70 days after pulp capping. The pieces containing the pulp-capped teeth were removed and processed for histologic analysis. Results. At 7 days, no dentin bridge formation was observed; G1 and G3 exhibited inflammatory pulpal alterations, whereas G2 presented only mild inflammatory infiltrate in the pulp tissue adjacent to the capping material, the remainder being intact. At 70 days, no specimen in G1 or G3 presented dentin bridge formation. The remaining pulp tissue exhibited severe inflammatory alterations and areas of necrosis. In G2, all specimens showed dentin bridge formation and absence of inflammation and mineralized tissue resorption. No bacteria were identified using Brown and Brenn staining techniques in all 3 groups at any observation period. Conclusion. According to the conditions of this study, direct pulp capping with the self-etching adhesive system did not allow pulp tissue repair and failed histopathologically in 100% of the cases. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e34-e40)