986 resultados para metered dose inhaler, nebulizer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A decision-theoretic framework is proposed for designing sequential dose-finding trials with multiple outcomes. The optimal strategy is solvable theoretically via backward induction. However, for dose-finding studies involving k doses, the computational complexity is the same as the bandit problem with k-dependent arms, which is computationally prohibitive. We therefore provide two computationally compromised strategies, which is of practical interest as the computational complexity is greatly reduced: one is closely related to the continual reassessment method (CRM), and the other improves CRM and approximates to the optimal strategy better. In particular, we present the framework for phase I/II trials with multiple outcomes. Applications to a pediatric HIV trial and a cancer chemotherapy trial are given to illustrate the proposed approach. Simulation results for the two trials show that the computationally compromised strategy can perform well and appear to be ethical for allocating patients. The proposed framework can provide better approximation to the optimal strategy if more extensive computing is available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fillets of five fish species were irradiated at 0, 1 and 3kGy to investigate whether the K-value test of freshness can be applied to irradiated fish. Following irradiation, the fillets were stored on ice and sampled regularly for K-value analysis. Hypoxanthine (Hx) and total nucleotide content were also determined on fillets of two species. K-values of irradiated fillets were generally lower than those of unirradiated controls. Hypoxanthine levels paralleled the K-value changes. These results indicated that quality standards based on K-values or Hx levels that have been set for unirradiated species cannot be directly applied to fish that has been irradiated. Total nucleotide content did not appear to be affected by irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design Retrospective review of prospectively collected data. Objectives To analyze intervertebral (IV) fusion after thoracoscopic anterior spinal fusion (TASF) and explore the relationship between fusion scores and key clinical variables. Summary of Background Information TASF provides comparable correction with some advantages over posterior approaches but reported mechanical complications, and their relationship to non-union and graft material is unclear. Similarly, the optimal combination of graft type and implant stiffness for effecting successful radiologic union remains undetermined. Methods A subset of patients from a large single-center series who had TASF for progressive scoliosis underwent low-dose computed tomographic scans 2 years after surgery. The IV fusion mass in the disc space was assessed using the 4-point Sucato scale, where 1 indicates <50% and 4 indicates 100% bony fusion of the disc space. The effects of rod diameter, rod material, graft type, fusion level, and mechanical complications on fusion scores were assessed. Results Forty-three patients with right thoracic major curves (mean age 14.9 years) participated in the study. Mean fusion scores for patient subgroups ranged from 1.0 (IV levels with rod fractures) to 2.2 (4.5-mm rod with allograft), with scores tending to decrease with increasing rod size and stiffness. Graft type (autograft vs. allograft) did not affect fusion scores. Fusion scores were highest in the middle levels of the rod construct (mean 2.52), dropping off by 20% to 30% toward the upper and lower extremities of the rod. IV levels where a rod fractured had lower overall mean fusion scores compared to levels without a fracture. Mean total Scoliosis Research Society (SRS) questionnaire scores were 98.9 from a possible total of 120, indicating a good level of patient satisfaction. Conclusions Results suggest that 100% radiologic fusion of the entire disc space is not necessary for successful clinical outcomes following thoracoscopic anterior selective thoracic fusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In spite of the extensive use of phosphine fumigation around the world to control insects in stored grain, and the knowledge that grain sorbs phosphine, the effect of concentration on sorption has not been quantified. A laboratory study was undertaken, therefore, to investigate the effect of phosphine dose on sorption in wheat. Wheat was added to glass flasks to achieve filling ratios of 0.25-0.95, and the flasks were sealed and injected with phosphine at 0.1-1.5 mg L-1 based on flask volume. Phosphine concentration was monitored for 8 days at 25°C and 55% RH. RESULTS: When sorption occurred, phosphine concentration declined with time and was approximately first order, i.e. the data fitted an exponential decay equation. Percentage sorption per day was directly proportional to filling ratio, and was negatively correlated with dose for any given filling ratio. Based on the results, a tenfold increase in dose would result in a halving of the sorption constant and the percentage daily loss. Wheat was less sorptive if it was fumigated for a second time. CONCLUSIONS: The results have implications for the use of phosphine for control of insects in stored wheat. This study shows that dose is a factor that must be considered when trying to understand the impact of sorption on phosphine concentration, and that there appears to be a limit to the capacity of wheat to sorb phosphine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Management of insecticide resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pimelea species (or desert riceflower) are small native plants endemic to the drier inland pastoral regions of Australia, which cause a unique syndrome in grazing cattle characterised by submandibular oedema and oedema in the brisket area as a result of right-sided heart failure attributed to the toxin simplexin. Field evidence suggests that poisoning can occur through minor, inadvertent consumption of Pimelea plant material, but the minimum simplexin intake required to induce Pimelea poisoning is not known. In this study, mild Pimelea poisoning was induced at a daily dose of 12.5 mg Pimelea/kg bodyweight per day, equivalent to 2.5 µg simplexin/kg bodyweight per day, demonstrating the high potential toxicity of these plant species. Effects in all animals diminished with prolonged low dose feeding and we postulate that these animals developed mechanisms for detoxifying simplexin, 1, possibly through rumen bacteria adaptation or activation of liver enzymes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

- Background Nilotinib and dasatinib are now being considered as alternative treatments to imatinib as a first-line treatment of chronic myeloid leukaemia (CML). - Objective This technology assessment reviews the available evidence for the clinical effectiveness and cost-effectiveness of dasatinib, nilotinib and standard-dose imatinib for the first-line treatment of Philadelphia chromosome-positive CML. - Data sources Databases [including MEDLINE (Ovid), EMBASE, Current Controlled Trials, ClinicalTrials.gov, the US Food and Drug Administration website and the European Medicines Agency website] were searched from search end date of the last technology appraisal report on this topic in October 2002 to September 2011. - Review methods A systematic review of clinical effectiveness and cost-effectiveness studies; a review of surrogate relationships with survival; a review and critique of manufacturer submissions; and a model-based economic analysis. - Results Two clinical trials (dasatinib vs imatinib and nilotinib vs imatinib) were included in the effectiveness review. Survival was not significantly different for dasatinib or nilotinib compared with imatinib with the 24-month follow-up data available. The rates of complete cytogenetic response (CCyR) and major molecular response (MMR) were higher for patients receiving dasatinib than for those with imatinib for 12 months' follow-up (CCyR 83% vs 72%, p < 0.001; MMR 46% vs 28%, p < 0.0001). The rates of CCyR and MMR were higher for patients receiving nilotinib than for those receiving imatinib for 12 months' follow-up (CCyR 80% vs 65%, p < 0.001; MMR 44% vs 22%, p < 0.0001). An indirect comparison analysis showed no difference between dasatinib and nilotinib for CCyR or MMR rates for 12 months' follow-up (CCyR, odds ratio 1.09, 95% CI 0.61 to 1.92; MMR, odds ratio 1.28, 95% CI 0.77 to 2.16). There is observational association evidence from imatinib studies supporting the use of CCyR and MMR at 12 months as surrogates for overall all-cause survival and progression-free survival in patients with CML in chronic phase. In the cost-effectiveness modelling scenario, analyses were provided to reflect the extensive structural uncertainty and different approaches to estimating OS. First-line dasatinib is predicted to provide very poor value for money compared with first-line imatinib, with deterministic incremental cost-effectiveness ratios (ICERs) of between £256,000 and £450,000 per quality-adjusted life-year (QALY). Conversely, first-line nilotinib provided favourable ICERs at the willingness-to-pay threshold of £20,000-30,000 per QALY. - Limitations Immaturity of empirical trial data relative to life expectancy, forcing either reliance on surrogate relationships or cumulative survival/treatment duration assumptions. - Conclusions From the two trials available, dasatinib and nilotinib have a statistically significant advantage compared with imatinib as measured by MMR or CCyR. Taking into account the treatment pathways for patients with CML, i.e. assuming the use of second-line nilotinib, first-line nilotinib appears to be more cost-effective than first-line imatinib. Dasatinib was not cost-effective if decision thresholds of £20,000 per QALY or £30,000 per QALY were used, compared with imatinib and nilotinib. Uncertainty in the cost-effectiveness analysis would be substantially reduced with better and more UK-specific data on the incidence and cost of stem cell transplantation in patients with chronic CML. - Funding The Health Technology Assessment Programme of the National Institute for Health Research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a novel approach to treatment planning for focal brachytherapy utilizing a biologically based inverse optimization algorithm and biological imaging to target an ablative dose at known regions of significant tumour burden and a lower, therapeutic dose to low risk regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

White nectarines (Prunus persica var. nucipersica) were fumigated with methyl bromide (MB) at a nominal treatment dose of 18 g m-3 at 18°C for 5 h and 30 min as a quarantine disinfestation treatment against Bactrocera tryoni, the Queensland fruit fly. Three large scale trials were conducted against each of the four immature lifestages, eggs and first, second and third instars. There were no survivors from the estimated 43,614 eggs, 41,873 first instars, 41,345 second instars and 33,549 third instars treated, thereby resulting in an efficacy of GROTERDAN99.99% mortality at the 95% confidence level for each lifestage. Of the 12 trials reported herein, the highest concentration of MB, sampled from the chamber headspace analysed by gas chromatography, was 18.7 g m-3. The maximum chamber temperature from 5 min readings was 19.7°C and the maximum fruit core temperature was 19.5°C. The treatment time for all trials was exactly 5.5 h. Thus the recommended treatment dose to disinfest nectarines from B. tryoni is 19.0 g m-3 MB at 20.0°C for 5.5 h. Fruit quality trials were conducted on white nectarines at three combinations of treatment parameters: 15 g m-3 MB at 19°C for 5.25 h; 18 g m-3 MB at 19°C for 5.5 h and 21 g m-3 MB at 19°C for 5.5 h. The fruit were stored at 0, 4 and 8 days at 4°C and 8 days at 4°C followed by 4 d at 22°C. They were then were assessed for skin colour, flesh colour, skin defects, flesh defects, fruit weight loss, flesh firmness, total soluble solids, titratable acidity and rots. There was no significant difference between untreated control and MB treated fruits in any of the parameters measured. Thus the treatments did not have adverse effects on fruit quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Common variants in WNT pathway genes have been associated with bone mass and fat distribution, the latter predicting diabetes and cardiovascular disease risk. Rare mutations in the WNT co-receptors LRP5 and LRP6 are similarly associated with bone and cardiometabolic disorders. We investigated the role of LRP5 in human adipose tissue. Subjects with gain-of-function LRP5 mutations and high bone mass had enhanced lower-body fat accumulation. Reciprocally, a low bone mineral density-associated common LRP5 allele correlated with increased abdominal adiposity. Ex vivo LRP5 expression was higher in abdominal versus gluteal adipocyte progenitors. Equivalent knockdown of LRP5 in both progenitor types dose-dependently impaired β-catenin signaling and led to distinct biological outcomes: diminished gluteal and enhanced abdominal adipogenesis. These data highlight how depot differences in WNT/β-catenin pathway activity modulate human fat distribution via effects on adipocyte progenitor biology. They also identify LRP5 as a potential pharmacologic target for the treatment of cardiometabolic disorders. © 2015 The Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation therapy (RT) plays currently significant role in curative treatments of several cancers. External beam RT is carried out mostly by using megavoltage beams of linear accelerators. Tumor eradication and normal tissue complications correlate to dose absorbed in tissues. Normally this dependence is steep and it is crucial that actual dose within patient accurately correspond to the planned dose. All factors in a RT procedure contain uncertainties requiring strict quality assurance. From hospital physicist´s point of a view, technical quality control (QC), dose calculations and methods for verification of correct treatment location are the most important subjects. Most important factor in technical QC is the verification that radiation production of an accelerator, called output, is within narrow acceptable limits. The output measurements are carried out according to a locally chosen dosimetric QC program defining measurement time interval and action levels. Dose calculation algorithms need to be configured for the accelerators by using measured beam data. The uncertainty of such data sets limits for best achievable calculation accuracy. All these dosimetric measurements require good experience, are workful, take up resources needed for treatments and are prone to several random and systematic sources of errors. Appropriate verification of treatment location is more important in intensity modulated radiation therapy (IMRT) than in conventional RT. This is due to steep dose gradients produced within or close to healthy tissues locating only a few millimetres from the targeted volume. The thesis was concentrated in investigation of the quality of dosimetric measurements, the efficacy of dosimetric QC programs, the verification of measured beam data and the effect of positional errors on the dose received by the major salivary glands in head and neck IMRT. A method was developed for the estimation of the effect of the use of different dosimetric QC programs on the overall uncertainty of dose. Data were provided to facilitate the choice of a sufficient QC program. The method takes into account local output stability and reproducibility of the dosimetric QC measurements. A method based on the model fitting of the results of the QC measurements was proposed for the estimation of both of these factors. The reduction of random measurement errors and optimization of QC procedure were also investigated. A method and suggestions were presented for these purposes. The accuracy of beam data was evaluated in Finnish RT centres. Sufficient accuracy level was estimated for the beam data. A method based on the use of reference beam data was developed for the QC of beam data. Dosimetric and geometric accuracy requirements were evaluated for head and neck IMRT when function of the major salivary glands is intended to be spared. These criteria are based on the dose response obtained for the glands. Random measurement errors could be reduced enabling lowering of action levels and prolongation of measurement time interval from 1 month to even 6 months simultaneously maintaining dose accuracy. The combined effect of the proposed methods, suggestions and criteria was found to facilitate the avoidance of maximal dose errors of up to even about 8 %. In addition, their use may make the strictest recommended overall dose accuracy level of 3 % (1SD) achievable.