141 resultados para electrocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Subarachnoid infusion of most contrast mediums and the steps involved in performing a cervical myelography have adverse affects that can discourage its use in the radiographic diagnosis of spinal cord diseases. Thus, the cardiovascular and respiratory alterations associated with neck flexion, subarachnoid puncture, and cerebrospinal fluid drainage during subarachnoid infusion of ioversol (320mgI/mL) in dogs under general anesthesia using isoflurane were evaluated. The dogs received subarachnoid infusion of autologous cerebrospinal fluid kept at 38°C - control group (GC); ioversol 0.3mL/kg at 25°C (GI25) and ioversol 0.3mL/kg heated to 38°C (GI38). Each dog had its heart rate (HR), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), respiratory rate (RR), oxyhemoglobin saturation (SaO2) and electrocardiography readings (PR and QT intervals) recorded. Group comparisons showed no statistical difference regarding neck positioning, subarachnoid puncture, and subarachnoid infusion of contrast medium on HR, RR and SaO2, cardiac rhythm or conduction. However, isoflurane significantly increased PR and QT intervals. Based on these findings, it is concluded that the steps involved in cervical myelography and the use of ioversol 320mgI/mL at 0.3mL/kg (25ºC and 38ºC) during cervical myelography did not result in relevant cardiovascular and respiratory alterations, except for an elevation in arterial pressure after injection of ioversol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate cardiovascular and respiratory effects associated with neck flexion, subarachnoid puncture, cerebrospinal fluid drainage and the subarachnoid infusion of ioversol (320mgl/mL) in dogs under isoflurane general anesthesia. The dogs received infusion of: autologous cerebrospinal fluid at 38 degrees C (GC - control group); ioversol 0.3mL/ Kg at 25 degrees C (GI25) and heated to 38 degrees C (GI38). Heart rate, systolic and diastolic arterial pressure, respiratory rate, oxyhemoglobin saturation and electrocardiography readings were recorded. The results showed that cervical myelography with ioversol 320mgl/mL at 0.3mL/Kg (25 C-degrees and 38C degrees) did not significantly alter recorded parameters, except for an elevation in arterial pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate the electrocardiography effects (ECG), sedation time and quality of recovery due to buprenorphine (G1) and butorphanol (G2) administration in dogs pretreated with acepromazine. Seven adult dogs were submitted to both protocols, with a thirty days interval between groups. G1 animals were premedicated with acepromazine (0.1 mg/kg) followed 10 minutes later with buprenorphine (0.005 mg/kg), both applied intravenously. The same procedure was performed for G2 employing butorphanol (0.3 mg/kg) instead of buprenorphine. The measurements of the variables heart rate (HR), duration and amplitude of P wave, P-R intervals (PR), QRS complex duration, R wave amplitude, Q-T intervals (QT) and R-R intervals (RR) were taken immediately before application of acepromazine (M0), 10 minute after administration of acepromazine (M10) and 10 minutes after opioids administration (M20). Serial measurements were carried out in 10 minute intervals after the administration of butorphanol or buprenorphine up to 60 minutes. Numeric data were submitted to Tukey Analysis (p < 0.05). The amplitude of P wave decreased 30 minutes after the administration of the butorphanol. Sedation time was longer in G1 (78 minutes) than G2 (72 minutes) and recovery was good in both groups. These results indicate that butorphanol or buprenorphine produced discreet alterations on ECG, which don´t contraindicate its clinical use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrocardiogram (ECG) is an important tool used in the diagnosis of cardiac arrhythmias, since it gives the graphic representation of depolarization and repolarization processes of the cardiac muscle. This study allows recording the electrical activity of myocardial cells and the underlying differences in electric potential: the magnitude of this difference is measured in millivolts (mV), and its duration is measured in seconds. The ECG is indicated when an irregular rhythm is detected during physical examination, such as bradycardias, tachycardias or arrhythmias that are not secondary to breathing, in animals with a history of syncope or weakness, for monitoring the effectiveness of antiarrhythmic therapy, in cases of putative pleural or pericardial effusion, and also in systemic diseases that lead to arrhythmia. For a reliable assessment, the ECG must be evaluated in conjunction with findings from the physical examination and clinical signs of each patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents the electrocardiogram findings from 97 captive tufted capuchin monkeys (Cebus apella) at the Sao Paulo Zoo (Sao Paulo, Brazil) while under ketamine anesthesia. The results did not differ greatly from data of domestic carnivores or other studied primate species. The most common rhythm recorded was normal sinus rhythm, followed by normal sinus rhythm with wandering pacemaker. Electrical axis varied from 0 degrees to -150 degrees but was most commonly between +60 degrees and +90 degrees. QRS complexes were predominantly positive in leads DI, DII, DIII, and AVF. These findings allow for the recognition of abnormal rhythms in these primate species and can contribute to future investigations into the cardiovascular diseases routinely diagnosed in primates and humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Chagas' disease has spread throughout Latin America because of the high rate of migration among these countries. Approximately 30% of Chagas' patients will develop cardiomyopathy, and 10% of these will develop severe cardiac damage leading to heart failure. Beta-blockade improves symptoms and survival in heart failure patients; however, its efficacy has not been well established in Chagas' disease. We evaluated the role of carvedilol in cardiac remodeling and mortality in a Chagas' cardiomyopathy animal model. METHODS: We studied Trypanosoma cruzi infection in 55 Syrian hamsters that were divided into three groups: control (15), infected (20), and infected + carvedilol (20). Animals underwent echocardiography, electrocardiography, and morphometry for collagen evaluation in ventricles stained with picrosirius red. RESULTS: The left ventricular diastolic diameter did not change between groups, although it was slightly larger in infected groups, as was left ventricular systolic diameter. Fractional shortening also did not change between groups, although it was slightly lower in infected groups. Collagen accumulation in the interstitial myocardial space was significantly higher in infected groups and was not attenuated by carvedilol. The same response was observed in the perivascular space. The survival curve showed significantly better survival in the control group compared with the infected groups; but no benefit of carvedilol was observed during the study. However, in the acute phase (up to 100 days of infection), carvedilol did reduce mortality. CONCLUSION: Carvedilol did not attenuate cardiac remodeling or mortality in this model of Chagas' cardiomyopathy. The treatment did improve survival in the acute phase of the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring foetal health is a very important task in clinical practice to appropriately plan pregnancy management and delivery. In the third trimester of pregnancy, ultrasound cardiotocography is the most employed diagnostic technique: foetal heart rate and uterine contractions signals are simultaneously recorded and analysed in order to ascertain foetal health. Because ultrasound cardiotocography interpretation still lacks of complete reliability, new parameters and methods of interpretation, or alternative methodologies, are necessary to further support physicians’ decisions. To this aim, in this thesis, foetal phonocardiography and electrocardiography are considered as different techniques. Further, variability of foetal heart rate is thoroughly studied. Frequency components and their modifications can be analysed by applying a time-frequency approach, for a distinct understanding of the spectral components and their change over time related to foetal reactions to internal and external stimuli (such as uterine contractions). Such modifications of the power spectrum can be a sign of autonomic nervous system reactions and therefore represent additional, objective information about foetal reactivity and health. However, some limits of ultrasonic cardiotocography still remain, such as in long-term foetal surveillance, which is often recommendable mainly in risky pregnancies. In these cases, the fully non-invasive acoustic recording, foetal phonocardiography, through maternal abdomen, represents a valuable alternative to the ultrasonic cardiotocography. Unfortunately, the so recorded foetal heart sound signal is heavily loaded by noise, thus the determination of the foetal heart rate raises serious signal processing issues. A new algorithm for foetal heart rate estimation from foetal phonocardiographic recordings is presented in this thesis. Different filtering and enhancement techniques, to enhance the first foetal heart sounds, were applied, so that different signal processing techniques were implemented, evaluated and compared, by identifying the strategy characterized on average by the best results. In particular, phonocardiographic signals were recorded simultaneously to ultrasonic cardiotocographic signals in order to compare the two foetal heart rate series (the one estimated by the developed algorithm and the other provided by cardiotocographic device). The algorithm performances were tested on phonocardiographic signals recorded on pregnant women, showing reliable foetal heart rate signals, very close to the ultrasound cardiotocographic recordings, considered as reference. The algorithm was also tested by using a foetal phonocardiographic recording simulator developed and presented in this research thesis. The target was to provide a software for simulating recordings relative to different foetal conditions and recordings situations and to use it as a test tool for comparing and assessing different foetal heart rate extraction algorithms. Since there are few studies about foetal heart sounds time characteristics and frequency content and the available literature is poor and not rigorous in this area, a data collection pilot study was also conducted with the purpose of specifically characterising both foetal and maternal heart sounds. Finally, in this thesis, the use of foetal phonocardiographic and electrocardiographic methodology and their combination, are presented in order to detect foetal heart rate and other functioning anomalies. The developed methodologies, suitable for longer-term assessment, were able to detect heart beat events correctly, such as first and second heart sounds and QRS waves. The detection of such events provides reliable measures of foetal heart rate, potentially information about measurement of the systolic time intervals and foetus circulatory impedance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rodents are most useful models to study physiological and pathophysiological processes in early development, because they are born in a relatively immature state. However, only few techniques are available to monitor non-invasively heart frequency and respiratory rate in neonatal rodents without restraining or hindering access to the animal. Here we describe experimental procedures that allow monitoring of heart frequency by electrocardiography (ECG) and breathing rate with a piezoelectric transducer (PZT) element without hindering access to the animal. These techniques can be easily installed and are used in the present study in unrestrained awake and anesthetized neonatal C57/Bl6 mice and Wistar rats between postnatal day 0 and 7. In line with previous reports from awake rodents we demonstrate that heart rate in rats and mice increases during the first postnatal week. Respiratory frequency did not differ between both species, but heart rate was significantly higher in mice than in rats. Further our data indicate that urethane, an agent that is widely used for anesthesia, induces a hypoventilation in neonates whilst heart rate remains unaffected at a dose of 1 g per kg body weight. Of note, hypoventilation induced by urethane was not detected in rats at postnatal 0/1. To verify the detected hypoventilation we performed blood gas analyses. We detected a respiratory acidosis reflected by a lower pH and elevated level in CO2 tension (pCO2) in both species upon urethane treatment. Furthermore we found that metabolism of urethane is different in P0/1 mice and rats and between P0/1 and P6/7 in both species. Our findings underline the usefulness of monitoring basic cardio-respiratory parameters in neonates during anesthesia. In addition our study gives information on developmental changes in heart and breathing frequency in newborn mice and rats and the effects of urethane in both species during the first postnatal week.