980 resultados para Removable partial denture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Squamous cell carcinoma is a malignant epithelial neoplasm characterized by variable clinical manifestations. When located in the gingiva, this neoplasm may mimic common inflammatory lesions. The aim of this study was to report a case of atypical squamous cell carcinoma, in which the patient had no risk factors for the development of this neoplasm. A 61 year old Caucasian female was seen with a 3 month history of a rapidly growing, painful nodule in the gingiva adjacent to tooth #11. Clinical examination revealed a proliferative lesion in the vestibular marginal gingiva of teeth #11 and #12, presenting with purulent exudation. Thus, in view of the clinical symptoms and differential diagnosis of an infectious granulomatous process and malignant neoplasm, an incisional biopsy was obtained from the lesion. The diagnosis of squamous cell carcinoma was made and fourteen days after incisional biopsy, healing was found to be unsatisfactory. The patient was referred for treatment consisting of surgical excision of the tumour. A removable partial denture was fabricated for rehabilitation, one month after surgery of the maxilla; the patient was submitted to dissection of the regional lymph nodes and radiotherapy for an additional 3 months. Three years after the end of treatment, the patient continues to be followed-up and does not show any sign of recurrence. Gingival squamous cell carcinoma is a condition which chance of cure is higher when carcinomatous lesions are diagnosed and treated early. In this instance dentists play an important role in early detection of gingival squamous cell carcinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alveolar wall fenestrations are common during implant placement. The aim of this paper is to report a case where a peri-implant bone fenestration was reconstructed immediately after implant placement by an autogenous mandibular bone block. A male patient was referred to the Department of Surgical and Integrated Clinics to substitute his Kennedy´s Class IV removable partial denture for an implantsupported fixed prosthesis. A peri-implant bone fenestration at the buccal wall was seen at the region of 12, being reconstructed by a mandibular bone block secured by a bicortical screw. Six months later the surgical procedures, an implant-supported complete fixed partial prosthesis was developed. The autogenous bone block harvested from the mandibular ramus was a safe alternative to reconstruct the peri-implant bone defect such as fenestration types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The free-end removable partial dentures (RPD) shows a complicated and peculiar biomechanical behavior that impose high occlusion forces to the abutment teeth. By this way, the aim of this study was to evaluate the several factors that influence the clasps indication to free-end RPD. It was analysed 84 designed and planned study models of 71 patients, involving 130 clasps near-by a free-end; followed by clinical and radiographical informations. It was observed that bar clasps (“T”, “Tmod”, “i”) were used in 88.46% of abutment teeth. In the others (11.55%), it was used simple, combinated or ring circumferential clasps, and MDL. In abutment teeth with high equator line the “i” clasps were predominant (48.48%). The “Tmod” clasps were predominant in abutment teeth with low equator line (50%) or in middle third (51.35%) and “T” clasps were predominant in inclined equators with mesio-buccal (56.52%) or disto-buccal (66.66%) retention. In the posterior abutment teeth, it was prevalent the distal rest (63.52%) and embracing to the adjacent tooth. Some others factors like long clinical crown (5.38%), wrong position of abutment teeth (4.61%), aesthetics (3.07%), retention in alveolar ridge (2.3%), fragility of abutment teeth (1.53%), short clinical crown (0.76%) and short space to the clasp (0.76%) influenced directly during the clasps selection. Factors like mobility of abutment teeth, height of muscular insertions, depth of buccal fornix and antagonist arch acted like secondary factors. After the informations analysis it may be concluded that the bar clasps with distal rest and embracing to the adjacent tooth were the most indicated to free-end RPD

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rehabilitation with mandibular distal extension removable partial dentures (DERPD) is complex and the use of implants has been improving the functioning of this approach. The insertion bony level around of the last support tooth is an aggravating factor, since it can harm the longevity of the treatment. Thus, the aim of this research was to evaluate the displacement tendency of a mandibular DERPD associated to an implant, with different insertion bony levels and different connections between the RPD and the support tooth, by finite element analysis. Eight models were made: MA - DERPD, incisal rest, no bony loss; MB - DERPD, distal plate, no bony loss; MC - DERPD, incisal rest, no bony loss, with implant and ERA system; MD - DERPD, distal plate, no bony loss, with implant and ERA system; ME - DERPD, incisal rest, bony loss; MF - DERPD, distal plate, bony loss; MG - DERPD, incisal rest, bony loss, with implant and ERA system; MH - DERPD, distal plate, bony loss, with implant and ERA system. Loads of 50 N in each peak were applied. Displacement maps were obtained and showed that implant favors this association and the bony loss harms the prognostic of the prosthesis. It is concluded that: the introduction of the implant with ERA system reduced the displacement tendency of the tooth and supporting structures; introduction of distal plate reduced the movement tendency of the support tooth; the decrease of the periodontal support didn't influence significantly the displacement tendency of the models with distal plate distal, but it influenced the models with distal incisal rest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare and to evaluate the stability of the retentive force of cobalt-chromium (Co-Cr) circumferential clasps (control) to those with an acetyl resin retentive arm. METHODS: Sixteen specimens with a couple of circumferential clasps were made using Co-Cr over a metal model providing 0.25 mm undercuts. Eight specimens were fabricated without the anterior retentive arm, which was made later using acetyl resin (Dental D). Insertion and removal simulation test was performed through 7250 cycles. The retentive force was recorded in Newtons (N) for periods corresponding to 0, 1, 2, 3, 4, and 5 years. The data were subjected to ANOVA and Tukey test to compare periods and to Student's t test to compare groups (α=0.05). RESULTS: Mean (SD) is presented for Co-Cr and resin groups, respectively: 8.09(3.05) and 2.79(1.57) in period 0; 10.48(4.25) and 3.32(1.92) in 1 year; 10.09(4.15) and 3.47(1.81) in 2 years; 9.87(4.30) and 3.46(1.87) in 3 years; 9.46(3.93) and 3.27(1.59) in 4 years; 9.63(3.79) and 3.41(1.59) in 5 years. There were significant differences for Co-Cr between periods of 0 and 1 (p<0.001), 0 and 2 (p<0.01) and 0 and 3 (p<0.05). In the resin group, no significant differences were found between periods (p>0.05). Comparisons between the groups showed statistical differences for all tested periods: 0 (p=0.0012), 1 (p=0.0013), 2 (p=0.0019), 3 (p=0.0031), 4 (p=0.0027) and 5 years (p=0.0014). CONCLUSIONS: Acetyl resin retentive arms, even if only in the anterior clasps, can significantly reduce the retentive force, but this force remained stable after 5 years of simulated use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ausência de dentes posteriores inferiores representa dificuldades no planejamento e controle de próteses parciais removíveis, pois o suporte é proporcionado por dentes e mucosa, que apresentam características anatômicas diferentes. O planejamento de próteses parciais removíveis apoiadas sobre implantes na região distal torna a prótese dento-implanto-suportada e não dento-muco-suportada sendo, uma opção aos casos de extremidade livre. Por meio deste relato de caso, um paciente portador de arco classe II de Kennedy foi reabilitado com prótese parcial removível apoiada sobre implante na região distal. A colocação do implante resultou em uma oclusão mais estável, o que melhorou a funcionalidade da prótese e proporcionou maior conforto ao paciente. Observou-se que esta resolução pode ser uma alternativa viável de tratamento, pois apresenta custo reduzido em relação à prótese fixa sobre implantes, entretanto, requer um acompanhamento em longo prazo com uma série de casos para tornar-se um método rotineiro de tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.