989 resultados para resin


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flow responsive passive samplers offer considerable potential in nutrient monitoring in catchments; bridging the gap between the intermittency of grab sampling and the high cost of automated monitoring systems. A commercially available passive sampler was evaluated in a number of river systems encapsulating a gradient in storm response, combinations of diffuse and point source pressures, and levels of phosphorus and nitrogen concentrations. Phosphorus and nitrogen are sequestered to a resin matrix in a permeable cartridge positioned in line with streamflow. A salt tracer dissolves in proportion to advective flow through the cartridge. Multiple deployments of different cartridge types were undertaken and the recovery of P and N compared with the flow-weighted mean concentration (FWMC) from high-resolution bank-side analysers at each site. Results from the passive samplers were variable and largely underestimated the FWMC derived from the bank-side analysers. Laboratory tests using ambient river samples indicated good replication of advective throughflow using pumped water, although this appeared not to be a good analogue of river conditions where flow divergence was possible. Laboratory tests also showed good nutrient retention but not elution and these issues appeared to combine to limit the utility in ambient river systems at the small catchment scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To assess quantitatively variations in the extent of capillary basement membrane (BM) thickening between different retinal layers and within arterial and venous environments during diabetes. METHODS: One year after induction of experimental (streptozotocin) diabetes in rats, six diabetic animals together with six age-matched control animals were sacrificed and the retinas fixed for transmission electron microscopy (TEM). Blocks of retina straddling the major arteries and veins in the central retinal were dissected out, embedded in resin, and sectioned. Capillaries in close proximity to arteries or veins were designated as residing in either an arterial (AE) or a venous (VE) environment respectively, and the retinal layer in which each capillary was located was also noted. The thickness of the BM was then measured on an image analyser based two dimensional morphometric analysis system. RESULTS: In both diabetics and controls the AE capillaries had consistently thicker BMs than the VE capillaries. The BMs of both AE and VE capillaries from diabetics were thicker than those of capillaries in the corresponding retinal layer from the normal rats (p <or = 0.005). Also, in normal AE and VE capillaries and diabetic AE capillaries the BM in the nerve fibre layer (NFL) was thicker than that in either the inner (IPL) or outer (OPL) plexiform layers (p <or = 0.001). However, in diabetic VE capillaries the BMs of capillaries in the NFL were thicker than those of capillaries in the IPL (p <or = 0.05) which, in turn, had thicker BMs than capillaries in the OPL (p <or = 0.005). CONCLUSIONS: The variation in the extent of capillary BM thickening between different retinal layers within AE and VE environments may be related to differences in levels of oxygen tension and oxidative stress in the retina around arteries compared with that around veins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

White household paints are commonly encountered as evidence in the forensic laboratory but they often cannot be readily distinguished by color alone so Fourier transform infrared (FT-IR) microscopy is used since it can sometimes discriminate between paints prepared with different organic resins. Here we report the first comparative study of FT-IR and Raman spectroscopy for forensic analysis of white paint. Both techniques allowed the 51 white paint samples in the study to be classified by inspection as either belonging to distinct groups or as unique samples. FT-IR gave five groups and four unique samples; Raman gave seven groups and six unique samples. The basis for this discrimination was the type of resin and/ or inorganic pigments/extenders present. Although this allowed approximately half of the white paints to be distinguished by inspection, the other half were all based on a similar resin and did not contain the distinctive modifiers/pigments and extenders that allowed the other samples to be identified. The experimental uncertainty in the relative band intensities measured using FT-IR was similar to the variation within this large group, so no further discrimination was possible. However, the variation in the Raman spectra was larger than the uncertainty, which allowed the large group to be divided into three subgroups and four distinct spectra, based on relative band intensities. The combination of increased discrimination and higher sample throughput means that the Raman method is superior to FT-IR for samples of this type. © 2005 Society for Applied Spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon composite monoliths were prepared from a commercial phenolic resin mixed with just 1 wt% of carbon nanotubes (CNTs) followed by carbonization and physical activation with CO. The products possess a hierarchical macroporous-microporous structure and superior CO adsorption properties. In particular, they show the top-ranked CO capacity (52 mg CO per g adsorbent at 25 °C and 114 mmHg) under low CO partial pressures, which is of more relevance for flue gas applications. This matches or exceeds those of carbons produced by complex chemical activation and functionalization. Our study demonstrates an effective way to create narrow micropores through structural modification of carbon composites by CNTs. © 2013 The Royal Society of Chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To determine, by means of static fracture testing the effect of the tooth preparation design and the elastic modulus of the cement on the structural integrity of the cemented machined ceramic crown-tooth complex. 
Methods: Human maxillary extracted premolar teeth were prepared for all-ceramic crowns using two preparation designs; a standard preparation in accordance with established protocols and a novel design with a flat occlusal design. All-ceramic feldspathic (Vita MK II) crowns were milled for all the preparations using a CAD/CAM system (CEREC-3). The machined all-ceramic crowns were resin bonded to the tooth structure using one of three cements with different elastic moduli: Super-Bond C&B, Rely X Unicem and Panavia F 2.0. The specimens were subjected to compressive force through a 4 mm diameter steel ball at a crosshead speed of 1 mm/min using a universal test machine (Loyds Instrument Model LRX.). The load at the fracture point was recorded for each specimen in Newtons (N). These values were compared to a control group of unprepared/unrestored teeth. 
Results: There was a significant difference between the control group, with higher fracture strength, and the cemented samples regardless of the occlusal design and the type of resin cement. There was no significant difference in mean fracture load between the two designs of occlusal preparation using Super-Bond C&B. For the Rely X Unicem and Panavia F 2.0 cements, the proposed preparation design with a flat occlusal morphology provides a system with increased fracture strength. 
Significance: The proposed novel flat design showed less dependency on the resin cement selection in relation to the fracture strength of the restored tooth. The choice of the cement resin, with respect to its modulus of elasticity, is more important in the anatomic design than in the flat design. © 2013 Academy of Dental Materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential of multiple layer fibre-reinforced mouldings is of growing interest to the rotational moulding industry because of their cost/performance ratio. The particular problem that arises when using reinforcements in this process relate to the fact that the process is low shear and good mixing of resin and reinforcement is not optimum under those conditions. There is also a problem of the larger/heavier reinforcing agents segregating out of the powder to lay up on the inner part surface. In this study, short glass fibres were incorporated and distributed into a polymer matrix to produce fibre-reinforced polymer composites using the rotational moulding process and characterised in terms of morphology and mechanical properties. © 2011 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In wetland-adapted plants, such as rice, it is typically root apexes, sites of rapid entry for water/nutrients, where radial oxygen losses (ROLs) are highest. Nutrient/toxic metal uptake therefore largely occurs through oxidized zones and pH microgradients. However, the processes controlling the acquisition of trace elements in rice have been difficult to explore experimentally because of a lack of techniques for simultaneously measuring labile trace elements and O2/pH. Here, we use new diffusive gradients in thin films (DGT)/planar optode sandwich sensors deployed in situ on rice roots to demonstrate a new geochemical niche of greatly enhanced As, Pb, and Fe(II) mobilization into solution immediately adjacent to the root tips characterized by O2 enrichment and low pH. Fe(II) mobilization was congruent to that of the peripheral edge of the aerobic root zone, demonstrating that the Fe(II) mobilization maximum only developed in a narrow O2 range as the oxidation front penetrates the reducing soil. The Fe flux to the DGT resin at the root apexes was 3-fold higher than the anaerobic bulk soil and 27 times greater than the aerobic rooting zone. These results provide new evidence for the importance of coupled diffusion and oxidation of Fe in modulating trace metal solubilization, dispersion, and plant uptake.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel diffusive gradients in thin film probe developed comprises diffusive gel layer of silver iodide (AgI) and a back-up Microchelex resin gel layer. 2D high-resolution images of sulfide and trace metals were determined respectively on the AgI gel by densitometric analysis and on the Microchelex resin layer with laser-ablation-inductively-coupled plasma mass spectrometry (LA-ICP-MS).We investigated the validity of the analytical procedures used for the determination of sulfide and trace metals. We found low relative standard deviations on replicate measurements, linear trace-metal calibration curves between the LA-ICP-MS signal and the true trace-metal concentration in the resin gel, and a good agreement of the sulfide results obtained with the AgI resin gel and with other analytical methods. The method was applied on anoxic sediment pore waters in an estuarine and marine system. Simultaneous remobilization of sulfide and trace metals was observed in the marine sediment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bonded-in rod connections in timber possess many desirable attributes in terms of efficiency, manufacture, performance, aesthetics and cost. In recent years research has been conducted on such connections using fibre reinforced polymers (FRPs) as an alternative to steel. This research programme investigates the pull-out capacity of Basalt FRP rods bonded-in in low grade Irish Sitka Spruce. Embedded length is thought to be the most influential variable contributing to pull- out capacity of bonded-in rods after rod diameter. Previous work has established an optimum embedded length of 15 times the hole diameter. However, this work only considered the effects of axial stress on the bond using a pull-compression testing system which may have given an artificially high pull out capacity as bending effects were neglected. A hinge system was utilised that allows the effects of bending force to be taken in to consideration along with axial forces in a pull-out test. This paper describes an experimental programme where such pull-bending tests were carried out on samples constructed of 12mm diameter BFRP bars with a 2mm glueline thickness and embedded lengths between 80mm and 280mm bonded-in to low-grade timber with an epoxy resin. Nine repetitions of each were tested. A clear increase in pull-out strength was found with increasing embedded length.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Older dentate adults are a high caries risk group who could potentially benefit from the use of the atraumatic restorative treatment (ART). This study aimed to compare the survival of ART and a conventional restorative technique (CT) using rotary instruments and a resin-modified glass-ionomer for restoring carious lesions as part of a preventive and restorative programme for older adults after 2 years.

METHODS: In this randomised controlled clinical trial, 99 independently living adults (65-90 years) with carious lesions were randomly allocated to receive either ART or conventional restorations. The survival of restorations was assessed by an independent and blinded examiner 6 months, 1 year and 2 years after restoration placement.

RESULTS: Ninety-six (67.6%) and 121 (76.6%) restorations were assessed in the ART and CT groups, respectively, after 2 years. The cumulative restoration survival percentages after 2 years were 85.4% in the ART and 90.9% in the CT group. No statistically significant between group differences were detected (p=0.2050, logistic regression analysis).

CONCLUSIONS: In terms of restoration survival, ART was as effective as a conventional restorative approach to treat older adults after 2 years. This technique could be a useful tool to provide dental care for older adults particularly in the non-clinical setting. (Trial Registration number: ISRCTN 76299321).

CLINICAL SIGNIFICANCE: The results of this study show that ART presented survival rates similar to conventional restorations in older adults. ART appears to be a cost-effective way to provide dental care to elderly patients, particularly in out of surgery facilities, such as nursing homes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As described in the first paper of this two part series, the expansion of our older population and the concomitant reduction in levels of edentulism will result in an increase in the number of patients presenting in general practice with complex restorative challenges. The application of the concepts of minimal intervention dentistry and minimally invasive operative techniques may offer a powerful armamentarium to the general dentist to provide ethical and conservative treatment to older patients.

Clinical Relevance: When it is unavoidable, operative intervention should be as minimally invasive as practicable in older patients to preserve the longevity of their natural dentition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to compare two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the shortened dental arch (SDA) and conventional treatment using removable partial dentures (RPDs) using a randomised controlled clinical trial. The primary outcome measure for this study was impact on oral health-related quality of life (OHRQoL) measured using the short form of the oral health impact profile (OHIP-14).

METHODS: Patients aged 65 years and older were randomly allocated to two different treatment groups: the RPD group and the SDA group. For the RPD group each patient was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. For the SDA group, patients were restored to a premolar occlusion of 10 occluding pairs of natural and replacement teeth using resin bonded bridgework (RBB). OHRQoL was measured using the OHIP-14 questionnaire administered at baseline, 1 month, 6 months and 12 months after treatment intervention.

RESULTS: In total, 89 patients completed the RCT: 44 from the RPD group and 45 from the SDA group. Analysis using a mixed model of covariance (ANCOVA) illustrated that treatment according to the SDA concept resulted in significantly better mean OHIP-14 scores compared with RPD treatment (p<0.05). This result was replicated in both treatment centres used in the study.

CONCLUSIONS: In terms of impact on OHRQoL, treatment based on the SDA concept achieved significantly better results than that based on RPDs 12 months after treatment intervention (trial registration no. ISRCTN26302774).

CLINICAL SIGNIFICANCE: Functionally orientated treatment delivery resulted in significantly better outcomes compared to removable dentures in terms of impact on OHRQoL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, undergraduate students in University College Cork (UCC) have been taught to use amalgam as the first choice material for direct restoration of posterior cavities. Since 2005 the use of composite resins has replaced amalgam as the first choice material. An audit was conducted of all direct restorations placed by final year students from UCC from 2004 until 2009. Results showed that over a six year period, final year UCC dental undergraduate students placed proportionately more direct composite resin restorations and significantly fewer amalgam restorations. The need for and undergraduate exposure to, provision of amalgam restorations may have to be revisited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the cost-effectiveness of conventional treatment using partial dentures with functionally orientated treatment to replace missing teeth for partially dentate elders using a randomised controlled clinical trial.

BACKGROUND: In many countries, including the Republic of Ireland, the only publically funded treatment option offered to partially dentate older patients is a removable partial denture. However, evidence suggests that these removable prostheses are unpopular with patients and can potentially increase the risk of further dental disease and subsequent tooth loss.

MATERIALS AND METHODS: Fourty-four partially dentate patients aged 65 years and older were recruited. Patients were randomly assigned to the two treatment arms of the study. The conventional treatment group received removable partial dentures to replace all missing natural teeth. The functionally orientated group was restored to a Shortened Dental Arch (SDA) of 10 occluding contacts using resin-bonded bridgework (RBB). The costs associated with each treatment were recorded. Effectiveness was measured in terms of the impact on oral health-related quality of life (OHRQoL) using OHIP-14.

RESULTS: Both groups reported improvements in OHRQoL 1 month after completion of treatment. The conventional treatment group required 8.3 clinic visits as compared to 4.4 visits for the functionally orientated group. The mean total treatment time was 183 min 19 s for the conventional group vs. 124 min 8 s for the functionally orientated group. The average cost of treatment for the conventional group was 487.74 Euros compared to 356.20 Euros for the functional group.

CONCLUSIONS: Functionally orientated treatment was more cost-effective than conventional treatment in terms of treatment effect and opportunity costs to the patients' time.