Resumo:

Mixed calcium and copper oxalates, with different proportions of Ca2+ and Cu2+ ions, were precipitated by dimethyl oxalate hydrolysis in homogeneous solution. The compounds were evaluated by means of scanning electron microscopy, energy dispersive X-ray spectroscopy, thermogravimetry (TG), and differential thermal analysis (DTA). The results suggested quantitative precipitation without solid solution formation. From the TG and DTA curves, it was possible to evaluate the Ca2+ ion proportion in the solid phase and to confirm the precipitation of the individual species.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to enable the reuse of the large surplus volume of petroleum produced water for irrigation of crops inedible, the quality evaluation of this water is very important. This work aimed to evaluate the effectiveness of the diffusive gradient in thin films technique (DGT) for the determination of labile Cu (II), Mn (II) and Zn (II) in petroleum produced water destined to reuse in agriculture. Samples were collected at the exit of the wastewater treatment plant (WWTP) (after separation oil/water and flotation) of a Petrobrás onshore production region. Basically, the laboratory experiments with DGT devices involved the evaluation of the behavior of the main variables of the technique for determination of analytes in the samples (diffusion coefficients, immersion time, fractionation of organic and inorganic species, and performance of diffusion gels with different porosities, among others). Also, experiments were conducted based on the solid phase extraction (SPE) protocol with Chelex- 100 resin using previously established protocols to support the study. During the project the possibility of in situ immersions in water treatment plants was evaluated. The DGT technique presented satisfactory results for determination of Mn in produced water, and can be used for in situ determinations. However, the results obtained for Cu and Zn show the need of additional studies

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The studies of this work aimed to determine the labile fractions of manganese (Mn) in natural and drainage water samples collected around the Osamu Utsumi uranium mine, located in the municipality of Caldas, south-central region of Poços de Caldas- MG, using the technique of diffusion gradient in thin films (DGT). The DGT devices were mounted with Chelex-100 resin, polyacrylamide-agarose hydrogel (conventional porosity) and cellulose acetate membrane. The device were deployed up to 48 hours in six water samples collected from different areas around the uranium mine (075, 076, 022-E, 025-E, 014, and 041). The DGT devices immersed in each sample were gradually removed after 4, 8, 12, 24 and 48 hours. The pH of the samples ranged from 3.0 to 10.5, which influenced the lability and the sampling of the analyte by the Chelex-100 resin. The results showed a linear relationship between accumulated mass and sampling time (immersion curve) for samples 014 and 025-E (pH between 6 and 8) suggesting the ability of the DGT technique for sampling the analyte. The results obtained for samples 075 and 076 (pH<5) and samples 041 and 022-E (pH around 10) were characterized by nonlinear relationships. The values obtained by DGT were compared with Solid Phase Extraction (SPE) technique using Chelex-100. For samples 014 and 025-E, there was a good agreement between the results obtained by both techniques

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Indiscriminate and inappropriate use of pesticides in agriculture has been pointed out for increasing health problems and environmental damage. Considering that water resources are the principal destiny of those compounds after application, the present study presents optimization and validation of two simple and effi cient analytical methods for pesticides quantifi cation in both surface and groundwater. Were selected the pesticides more commonly used at Dourados (MS - Brazil), region with intense agricultural activity. Pesticides were preconcentrated by solid-phase extraction using C18 (500 mg) cartridges and then divided in two groups for elution and quantifi cation: 2.4-D and 2.4-DCP were eluted with methanol and quantifi ed by high performance liquid chromatography with ultra-violet detector (HPLC-UV) while atrazine, DIA, DEA, trifl uralin and methyl parathion were eluted with ethylacetate (1:1, v/v) and quantifi ed by gas chromatography with thermionic specifi c detector (GC-TSD). The methods showed satisfactory accuracy (76-107%) and precision (<12%) for the substances analyzed at the fortifi ed levels selected for the study, except for DIA (<51%). Study of pesticide stability also presented good results: C18 cartridges could be stored for at least for 21 days at -20ºC with no signs of the compounds degradability. Both methods limits of quantifi cation of the pesticides (0.22 - 0.48 μg L-1) are in accordance to the levels currently established by the Brazilian national legislation for pesticides in water. Although only the pesticide 2.4-D has been detected in two distinct collection points in the study period of time, this work warns for the requirement of systematical analysis of pesticides presence in water destined to human consume, principally in areas of intense agriculture activity. Such monitoring can provide subsidies for public environmental policies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and sensitive method using solid phase microextraction (SPME) and liquid chromatography (LC) with heated online desorption (SPME-LC) was developed and validated to analyze anticonvulsants (AEDs) in human plasma samples. A heated lab-made interface chamber was used in the desorption procedure, which allowed the transference of the whole extracted sample. The SPME conditions were optimized by applying an experimental design. Important factors are discussed such as fiber coating types, pH, extraction time and desorption conditions. The drugs were analyzed by LC, using a C18 column (150 mm 4.6 mm 5 mm); and 50 mmol L1 , pH ¼ 5.50 ammonium acetate buffer : acetonitrile : methanol (55 : 22 : 23 v/v) as the mobile phase with a flow rate of 0.8 mL min1 . The suggested method presented precision (intra-assay and inter-assay), linearity and limit of quantification (LOQ) all adequate for the therapeutic drug monitoring (TDM) of AEDs in plasma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports on the development and validation of a simple and sensitive method that uses solid phase extraction (SPE) and liquid chromatography with ultraviolet detection to analyze fluoxetine (FLX) and norfluoxetine (NFLX) in human plasma samples. A lab-made C18 SPE phase was synthesized by using a sol–gel process employing a low-cost silica precursor. This sorbent was fully characterized by nuclear magnetic resonance (NMR), Fourier-transform infrared spectroscopy (FT-IR), and scanning electron microscopy (SEM) to check the particles' shape, size and C18 functionalization. The lab-made C18 silica was used in the sample preparation step of human plasma by the SPE-HPLC-UV method. The method was validated in the 15 to 500 ng mL 1 range for both FLX and NFLX using a matrix matched curve. Detection limits of 4.3 and 4.2 ng mL 1 were obtained for FLX and NFLX, respectively. The repeatability and intermediary precision achieved varied from 7.6 to 15.0% and the accuracy ranged from 14.9 to 9.1%. The synthesized C18 sorbent was compared to commercial C18 sorbents. The average recoveries were similar (85–105%), however the lab-made C18 silica showed fewer interfering peaks in the chromatogram. After development and validation, the method using the lab-made C18 SPE was applied to plasma samples of patients under FLX treatment (n ¼ 6). The concentrations of FLX and NFLX found in the samples varied from 46.8–215.5 and 48.0–189.9 ng mL 1 , respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia - IQ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia - IQ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia - IQ