988 resultados para diagnostic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliographies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the accuracy and reliability of observational kinematic gait assessments performed via a low-bandwidth Internet link (118 kbit/s) and a higher-speed Internet link (128 kbit/s). Twenty-four subjects were randomized to either bandwidth group. Gait was assessed with the Gait Assessment Rating Scale (GARS) in the traditional manner, which is from video-recordings, and with repeated measurements via the online method. Online assessment was found to provide as accurate a measure of gait performance as the traditional assessment (limits of agreement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To improve the accuracy and completeness of reporting of studies of diagnostic accuracy, to allow readers to assess the potential for bias in a study, and to evaluate a study's generalisability. Methods The Standards for Reporting of Diagnostic Accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a two day consensus meeting, with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. Results The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25 item checklist, by using evidence, whenever available. A prototype of a flow diagram provides information about the method of patient recruitment, the order of test execution, and the numbers of patients undergoing the test under evaluation and the reference standard, or both. Conclusions Evaluation of research depends on complete and accurate reporting. If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of reporting of studies of diagnostic accuracy is less than optimal. Complete and accurate reporting is necessary to enable readers to assess the potential for bias in the study and to evaluate the generalisability of the results. A group of scientists and editors has developed the STARD (Standards for Reporting of Diagnostic Accuracy) statement to improve the reporting the quality of reporting of studies of diagnostic accuracy. The statement consists of a checklist of 25 items and flow diagram that authors can use to ensure that all relevant information is present. This explanatory document aims to facilitate the use, understanding and dissemination of the checklist. The document contains a clarification of the meaning, rationale and optimal use of each item on the checklist, as well as a short summary of the available evidence on bias and applicability. The STARD statement, checklist, flowchart and this explanation and elaboration document should be useful resources to improve reporting of diagnostic accuracy studies. Complete and informative reporting can only lead to better decisions in healthcare.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical microbiology and virology laboratories use nucleic acid tests (NAT) to detect genomic material of infectious organisms in clinical samples. Laboratories choose to perform assembled (or in-house) NAT if commercial assays are not available or if assembled NAT are more economical or accurate. One reason commercial assays are more expensive is because extensive validation is necessary before the kit is marketed, as manufacturers must accept liability for the performance of their assays, assuming their instructions are followed. On the other hand, it is a particular laboratory's responsibility to validate an assembled NAT prior to using it for testing and reporting results on human samples. There are few published guidelines for the validation of assembled NAT. One procedure that laboratories can use to establish a validation process for an assay is detailed in this document. Before validating a method, laboratories must optimise it and then document the protocol. All instruments must be calibrated and maintained throughout the testing process. The validation process involves a series of steps including: (i) testing of dilution series of positive samples to determine the limits of detection of the assay and their linearity over concentrations to be measured in quantitative NAT; (ii) establishing the day-to-day variation of the assay's performance; (iii) evaluating the sensitivity and specificity of the assay as far as practicable, along with the extent of cross-reactivity with other genomic material; and (iv) assuring the quality of assembled assays using quality control procedures that monitor the performance of reagent batches before introducing new lots of reagent for testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Videoconferencing has become a routine technique for the post-acute burns care of children in Queensland. We compared the agreement between clinical assessments conducted via videoconference and assessments conducted in the conventional, face-to-face manner (FTF). A total of 35 children with a previous burn injury were studied. Twenty-five children received three consecutive assessments: first FTF by a consultant in the outpatient department, then by a second consultant who reviewed the patient via videoconference, and then by the second consultant in person. The second consultant also reviewed another 10 children twice. At each review, the following variables were measured: scar colour, scar thickening, contractures, range of motion, the patient's level of general activity, any breakdown of the graft site, and adequacy of the consultation. Agreement between the two consultants when seeing patients FTF was moderately high, with an overall concordance of 85%. When videoconferencing was used, the level of agreement was almost the same, at 84%. If one consultant reviewed patients FTF first and then via videoconference, the overall concordance was 98%; if the process was reversed, the overall concordance was 97%. This study confirms that the quality of information collected during a videoconference appointment is comparable to that collected during a traditional, FTF appointment for a follow-up burns consultation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An emerging public health phenomenon is the increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) infections that are acquired outside of health care facilities. One lineage of community-acquired MRSA (CA-MRSA) is known as the Western Samoan phage pattern (WSPP) clone. The central aim of this study was to develop an efficient genotyping procedure for the identification of WSPP isolates. The approach taken was to make use of the highly variable region downstream of mecA in combination with a single nucleotide polymorphism (SNP) defined by the S. aureus multilocus sequence typing (MLST) database. The premise was that a combinatorial genotyping method that interrogated both a highly variable region and the genomic backbone would deliver a high degree of informative power relative to the number of genetic polymorphisms-interrogated. Thirty-five MRSA isolates were used for this study, and their gene contents and order downstream of mecA were determined. The CA-MRSA isolates were found to contain a truncated mecA downstream region consisting of mecA-HVR-IS431 mec-dcs-Ins117, and a PCR-based method for identifying this structure was developed. The hospital-acquired isolates were found to contain eight different mecA downstream regions, three of which were novel. The Minimum SNPs computer software program was used to mine the S. aureus MLST database, and the arcC 2726 polymorph was identified as 82% discriminatory for ST-30. A real-time PCR assay was developed to interrogate this SNP. We found that the assay for the truncated mecA downstream region in combination with the interrogation of arcC position 272 provided an unambiguous identification of WSPP isolates.