955 resultados para Ultrasound


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation describes a model for acoustic propagation in inhomogeneous flu- ids, and explores the focusing by arrays onto targets under various conditions. The work explores the use of arrays, in particular the time reversal array, for underwater and biomedical applications. Aspects of propagation and phasing which can lead to reduced focusing effectiveness are described. An acoustic wave equation was derived for the propagation of finite-amplitude waves in lossy time-varying inhomogeneous fluid media. The equation was solved numerically in both Cartesian and cylindrical geometries using the finite-difference time-domain (FDTD) method. It was found that time reversal arrays are sensitive to several debilitating factors. Focusing ability was determined to be adequate in the presence of temporal jitter in the time reversed signal only up to about one-sixth of a period. Thermoviscous absorption also had a debilitating effect on focal pressure for both linear and nonlinear propagation. It was also found that nonlinearity leads to degradation of focal pressure through amplification of the received signal at the array, and enhanced absorption in the shocked waveforms. This dissertation also examined the heating effects of focused ultrasound in a tissue-like medium. The application considered is therapeutic heating for hyperther- mia. The acoustic model and a thermal model for tissue were coupled to solve for transient and steady temperature profiles in tissue-like media. The Pennes bioheat equation was solved using the FDTD method to calculate the temperature fields in tissue-like media from focused acoustic sources. It was found that the temperature-dependence of the medium's background prop- erties can play an important role in the temperature predictions. Finite-amplitude effects contributed excess heat when source conditions were provided for nonlinear ef- fects to manifest themselves. The effect of medium heterogeneity was also found to be important in redistributing the acoustic and temperature fields, creating regions with hotter and colder temperatures than the mean by local scattering and lensing action. These temperature excursions from the mean were found to increase monotonically with increasing contrast in the medium's properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unstable arterial plaque is likely the key component of atherosclerosis, a disease which is responsible for two-thirds of heart attacks and strokes, leading to approximately 1 million deaths in the United States. Ultrasound imaging is able to detect plaque but as of yet is not able to distinguish unstable plaque from stable plaque. In this work a scanning acoustic microscope (SAM) was implemented and validated as tool to measure the acoustic properties of a sample. The goal for the SAM is to be able to provide quantitative measurements of the acoustic properties of different plaque types, to understand the physical basis by which plaque may be identified acoustically. The SAM consists of a spherically focused transducer which operates in pulse-echo mode and is scanned in a 2D raster pattern over a sample. A plane wave analysis is presented which allows the impedance, attenuation and phase velocity of a sample to be de- termined from measurements of the echoes from the front and back of the sample. After the measurements, the attenuation and phase velocity were analysed to ensure that they were consistent with causality. The backscatter coefficient of the samples was obtained using the technique outlined by Chen et al [8]. The transducer used here was able to determine acoustic properties from 10-40 MHz. The results for the impedance, attenuation and phase velocity were validated for high and low-density polyethylene against published results. The plane wave approximation was validated by measuring the properties throughout the focal region and throughout a range of incidence angles from the transducer. The SAM was used to characterize a set of recipes for tissue-mimicking phantoms which demonstrate indepen- dent control over the impedance, attenuation, phase velocity and backscatter coefficient. An initial feasibility study on a human artery was performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neoplastic tissue is typically highly vascularized, contains abnormal concentrations of extracellular proteins (e.g. collagen, proteoglycans) and has a high interstitial fluid pres- sure compared to most normal tissues. These changes result in an overall stiffening typical of most solid tumors. Elasticity Imaging (EI) is a technique which uses imaging systems to measure relative tissue deformation and thus noninvasively infer its mechanical stiffness. Stiffness is recovered from measured deformation by using an appropriate mathematical model and solving an inverse problem. The integration of EI with existing imaging modal- ities can improve their diagnostic and research capabilities. The aim of this work is to develop and evaluate techniques to image and quantify the mechanical properties of soft tissues in three dimensions (3D). To that end, this thesis presents and validates a method by which three dimensional ultrasound images can be used to image and quantify the shear modulus distribution of tissue mimicking phantoms. This work is presented to motivate and justify the use of this elasticity imaging technique in a clinical breast cancer screening study. The imaging methodologies discussed are intended to improve the specificity of mammography practices in general. During the development of these techniques, several issues concerning the accuracy and uniqueness of the result were elucidated. Two new algorithms for 3D EI are designed and characterized in this thesis. The first provides three dimensional motion estimates from ultrasound images of the deforming ma- terial. The novel features include finite element interpolation of the displacement field, inclusion of prior information and the ability to enforce physical constraints. The roles of regularization, mesh resolution and an incompressibility constraint on the accuracy of the measured deformation is quantified. The estimated signal to noise ratio of the measured displacement fields are approximately 1800, 21 and 41 for the axial, lateral and eleva- tional components, respectively. The second algorithm recovers the shear elastic modulus distribution of the deforming material by efficiently solving the three dimensional inverse problem as an optimization problem. This method utilizes finite element interpolations, the adjoint method to evaluate the gradient and a quasi-Newton BFGS method for optimiza- tion. Its novel features include the use of the adjoint method and TVD regularization with piece-wise constant interpolation. A source of non-uniqueness in this inverse problem is identified theoretically, demonstrated computationally, explained physically and overcome practically. Both algorithms were test on ultrasound data of independently characterized tissue mimicking phantoms. The recovered elastic modulus was in all cases within 35% of the reference elastic contrast. Finally, the preliminary application of these techniques to tomosynthesis images showed the feasiblity of imaging an elastic inclusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This PhD thesis describes work carried out on investigation of various interventions with the aim to optimise the anaesthetic management of patients scheduled to undergo operative fixation of hip fractures. We analysed the perioperative effects of continuous femoral nerve block, single preoperative dose of i.v. dexamethasone, the intention to deposit local anaesthetic in different locations around the femoral nerve during ultrasound guided femoral nerve block, continuous spinal anaesthesia and peri-surgical site infiltration with local anaesthetic after surgical fixation of hip fractures. Continuous femoral nerve block provided more effective preoperative analgesia six hours after the insertion of the perineural catheter compared to a standard opiate-based regimen in patients undergoing operative fixation of fractured hip. A single low dose of preoperative dexamethasone in the intervention group decreased pain scores by 75% six hours after the surgery. Both interventions had no major effect on the functional recovery in the first year after the surgical fixation of fractured hip. The results of the ultrasound guided femoral nerve block trial showed no clinical advantage of intending to deposit local anaesthetic circumferentially during performing femoral nerve block. Using the Dixon and Massey’s “up- and-down” method, we demonstrated that intrathecal 0.26 ml of 0.5% bupivacaine provided adequate surgical anaesthesia within 15 minutes in 50% of patients undergoing operative fixation of hip fracture. Finally, we demonstrated that local anaesthetic infiltration had no effect on pain scores 12 hours after the surgical fixation of fractured neck of femur. In addition to this original body of work, a review article was published on femoral nerve block highlighting the use of ultrasound guidance. In conclusion, the results of this thesis offer an insight into interventions aimed at optimising perioperative analgesia in patients scheduled to undergo operative fixation of hip fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The first childbirth has the greatest impact on a woman’s pelvic floor when major changes occur. The aim of this study was to comprehensively describe pelvic floor dysfunction (PFD) in young nulliparous women, and its correlation with postnatal pathology. Methods: A prospective study was performed at Cork University Maternity Hospital, Ireland. Initially 1484 nulliparous women completed the validated Australian Pelvic Floor Questionnaire at 15 weeks’ gestation and repeatedly at one year postnatally (N=872). In the second phase, at least one year postnatally, 202 participants without subsequent pregnancies attended the clinical follow up which included: pelvic organ prolapse quantification, a 3D-Transperineal ultrasound scan and collagen level assessment. Results: A high pre-pregnancy prevalence of various types of PFD was detected, which in the majority of cases persisted postnatally and included multiple types of PFD. The first birth had a negative impact on severity of pre-pregnancy symptoms in <15% of cases. Apart from prolapse, vaginal delivery, including instrumental delivery did not increase the risk of PFD symptoms, where as Caesarean section was protective for all types of PFD. The first birth had a bigger impact on pre-existing symptoms of overactive bladder compared to stress urinary incontinence. Pelvic organ prolapse is extremely prevalent in young primiparous women, however usually it is low grade and asymptomatic. Congenital factors and high collagen type III levels play an important role in the aetiology of pelvic organs prolapse. Levator ani trauma is present in one in three women after the first pregnancy and delivery. Conclusion: The main damage to the pelvic floor most likely occurs due to an undiagnosed congenital intrinsic weakness of the pelvic floor structures. PFD is highly associated with first childbirth, however it seems that pregnancy and delivery are contributing factors only which unmask the congenital intrinsic weakness of the pelvic floor support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The kidney's major role in filtration depends on its high blood flow, concentrating mechanisms, and biochemical activation. The kidney's greatest strengths also lead to vulnerability for drug-induced nephrotoxicity and other renal injuries. The current standard to diagnose renal injuries is with a percutaneous renal biopsy, which can be biased and insufficient. In one particular case, biopsy of a kidney with renal cell carcinoma can actually initiate metastasis. Tools that are sensitive and specific to detect renal disease early are essential, especially noninvasive diagnostic imaging. While other imaging modalities (ultrasound and x-ray/CT) have their unique advantages and disadvantages, MRI has superb soft tissue contrast without ionizing radiation. More importantly, there is a richness of contrast mechanisms in MRI that has yet to be explored and applied to study renal disease.

The focus of this work is to advance preclinical imaging tools to study the structure and function of the renal system. Studies were conducted in normal and disease models to understand general renal physiology as well as pathophysiology. This dissertation is separated into two parts--the first is the identification of renal architecture with ex vivo MRI; the second is the characterization of renal dynamics and function with in vivo MRI. High resolution ex vivo imaging provided several opportunities including: 1) identification of fine renal structures, 2) implementation of different contrast mechanisms with several pulse sequences and reconstruction methods, 3) development of image-processing tools to extract regions and structures, and 4) understanding of the nephron structures that create MR contrast and that are important for renal physiology. The ex vivo studies allowed for understanding and translation to in vivo studies. While the structure of this dissertation is organized by individual projects, the goal is singular: to develop magnetic resonance imaging biomarkers for renal system.

The work presented here includes three ex vivo studies and two in vivo studies:

1) Magnetic resonance histology of age-related nephropathy in sprague dawley.

2) Quantitative susceptibility mapping of kidney inflammation and fibrosis in type 1 angiotensin receptor-deficient mice.

3) Susceptibility tensor imaging of the kidney and its microstructural underpinnings.

4) 4D MRI of renal function in the developing mouse.

5) 4D MRI of polycystic kidneys in rapamycin treated Glis3-deficient mice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The initial results from clinical trials investigating the utility of acoustic radiation force impulse (ARFI) imaging for use with radio-frequency ablation (RFA) procedures in the liver are presented. To date, data have been collected from 6 RFA procedures in 5 unique patients. Large displacement contrast was observed in ARFI images of both pre-ablation malignancies (mean 7.5 dB, range 5.7-11.9 dB) and post-ablation thermal lesions (mean 6.2 dB, range 5.1-7.5 dB). In general, ARFI images provided superior boundary definition of structures relative to the use of conventional sonography alone. Although further investigations are required, initial results are encouraging and demonstrate the clinical promise of the ARFI method for use in many stages of RFA procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prostate and breast cancers are two of the most common types of cancer in the United States, and those cancers metastasize to bone in more than two thirds of patients. Recent evidence suggests that thermal therapy is effective at treating metastatic bone cancer. For example, thermal therapy enables targeted drug delivery to bone, ablation of cancer cells in bone marrow, and palliation of bone pain. Thermal therapy of bone metastases would be greatly improved if it were possible to image the temperature of the tissue surrounding the disease, which is usually red bone marrow (RBM). Unfortunately, current thermal imaging techniques are inaccurate in RBM.

This dissertation shows that many of the difficulties with thermal imaging of RBM can be overcome using a magnetic resonance phenomenon called an intermolecular multiple quantum coherence (iMQC). Herein, iMQCs are detected with a magnetic resonance imaging (MRI) pulse sequence called multi-spin-echo HOMOGENIZED with off resonance transfer (MSE-HOT). Compared to traditional methods, MSE-HOT provided ten-fold more accurate images of temperature change. Furthermore, MSE-HOT was translated to a human MRI scanner, which enabled imaging of RBM temperature during heating with a clinical focused ultrasound applicator. In summary, this dissertation develops a MRI technique that enables thermal imaging of RBM during thermal therapy of bone metastases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Preclinical imaging has a critical role in phenotyping, in drug discovery, and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review high-resolution computed tomography (CT) also known as micro-CT for small-animal imaging. We present the principles, the technologies, the image quality parameters, and the types of applications. We show that micro-CT can be used to provide not only morphological but also functional information such as cardiac function or vascular permeability. Another way in which micro-CT can be used in the study of both function and anatomy is by combining it with other imaging modalities, such as positron emission tomography or single-photon emission tomography. Compared to other modalities, micro-CT imaging is usually regarded as being able to provide higher throughput at lower cost and higher resolution. The limitations are usually associated with the relatively poor contrast mechanisms and the radiation damage, although the use of novel nanoparticle-based contrast agents and careful design of studies can address these limitations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Salt iodine content in Switzerland was raised from 7.5 to 15 mg per kg in 1980, and since then dietary iodine intake has been considered to be sufficient, even though a slight decrease due to imported food has recently been reported. The aim of this study was to establish normal values for thyroid volumes of school children who can be assumed to have had a sufficient iodine intake all their lifetime. Moreover, the present investigation was undertaken to verify that iodine sufficiency had been achieved equally in two regions each served by one of the two Swiss salt producers. Mean iodine concentration in urine spot samples from school children was 16.1 μg/dl, and it was identical in both the city of Lausanne (n=215) and the city of Solothurn (n=208). Thus it can be stated that in both cities (served by two different salt producers) iodine intake is equal and sufficient. Accordingly, thyroid volumes measured by ultrasound in school children aged 6 to 16 years were the same in both Lausanne (n=202) and Solothurn (n=207). Moreover, the age-adjusted median volumes at the 97th percentiles closely agree with and validate provisional international reference values recently proposed by the World Health Organisation and by the International Council for Control of Iodine Deficiency Disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the practice of laparoscopic appendectomy (LA) in Italy. Methods: On behalf of the Italian Society of Young Surgeons (SPIGC), an audit of LA was carried out through a written questionnaire sent to 800 institutions in Italy. The questions concerned the diffusion of laparoscopic surgery and LA over the period 1990 through 2001, surgery-related morbidity and mortality rates, indications for LA, the diagnostic algorithm adopted prior to surgery, and use of LA among young surgeons (<40 years). Results: A total of 182 institutions (22.7%) participated in the current audit, and accounted for a total number of 26863 LA. Laparoscopic surgery is performed in 173 (95%) institutions, with 144 (83.2%) routinely performing LA. The mean interval from introduction of laparoscopic surgery to inception of LA was 3.4 ± 2.5 years. There was an emergent basis for 8809 (32.8%) LA procedures (<6 hours of admission); 10314 (38.4%) procedures were performed on an urgent basis (<24 hours of admission); while 7740 (28.8%) procedures were elective. The conversion rate was 2.1% (561 cases) and was due to intraoperative complications in 197 cases (35.1%). Intraoperative complications ranged as high as 0.32%, while postoperative complications were reported in 1.2% of successfully completed LA. The mean hospital stay for successfully completed LA was 2.5 ± 1.05 days. The highest rate of intraoperative complications was reported as occurring during the learning curve phase of their experience (in their first 10 procedures) by 39.7% of the surgeons. LA was indicated for every case of suspected acute appendiceal disease by 51.8% of surgeons, and 44.8% order abdominal ultrasound (US) prior to surgery. A gynecologic counseling is deemed necessary only by 34.5% surgeons, while an abdominal CT scan is required only by 1.5%. The procedure is completed laparoscopically in the absence of gross appendiceal inflammation by 83%; 79.8% try to complete the procedure laparoscopically in the presence of concomitant disease; while 10.4% convert to open surgery in cases of suspected malignancy. Of responding surgeons aged under 40, 76.3% can perform LA, compared to 47.3% surgeons of all age categories. Conclusions: The low response rate of the present survey does not allow us to assess the diffusion of LA in Italy, but rather to appraise its practice in centers routinely performing laparoscopic surgery. In the hands of experienced surgeons, LA has morbidity rates comparable to those of international series. The higher diagnostic yield of laparoscopy makes it an invaluable tool in the management algorithm of women of childbearing age; its advantages in the presence of severe peritonitis are less clear-cut. Surgeons remain the main limiting factor preventing a wider diffusion of LA in our country, since only 47.3% of surgeons from the audited institutions can perform LA on a routine basis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper concerns the use of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste and specifically, the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of paste materials at the molecular level. Ultrasonic techniques are a widely used and a reliable form of non-destructive testing of materials. This is because techniques such as ultrasounds while used for testing or monitoring material properties, has offered immense benefits in applications where access to the sample is restricted or when handling the sample for testing could interfere with the monitoring or analysis process. Very often, this would mean that the measurements taken are not a true representation of the behaviour of the material (due to externally incorporated changes into the material's physical state during the removal or testing process). Ultrasonic based techniques are being increasingly used for quality control and production monitoring functions which requires evaluation of the changes in material properties over wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough, and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capacity to take rapid measurements in systems which are optically opaque. The viscometer and rheometer are two of the most widely used rheological instruments used in industry for monitoring the quality of solder pastes, during the production and packaging stage. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. It is for these reasons that materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers) are keen to see the development of simple, easy to use and accurate techniques for the theological characterisation of solder pastes. The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the application of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste through the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of lead-free solder paste containing different types of flux. Ultrasonic techniques offer a robust and reliable form of non-destructive testing of materials where access to the sample is restricted or when sample handling can interfere with the monitoring or analysis process due to externally incorporated changes to the material’s physical state or accidental contamination during the removal or testing process. Ultrasonic based techniques are increasingly used for quality control and production monitoring functions which requires evaluation of changes in material properties for a wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capability to take rapid measurements in systems which are optically opaque. The conventional industry approach for characterising the rheological properties of suspensions during processing/packaging stage is mainly through the use of viscometer and some through the use of rheometer. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. The ultrasound technique being proposed provides simple, yet accurate and easy to use solution for the in-situ rheological characterisation of solder pastes which will benefit the materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers). The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.