982 resultados para Allele frequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theory of optical subdivision techniques of dual-frequency laser interferometers is stated. And a novel optical subdivision technique is proposed originally to enhance resolution of a commercial interferometer by adding some corner-cubes. Then the performance of the interferometer is tested. The interferometer resolution of 1.24 nm and the average error of below 2 nm are achieved by using the technique. The most novel of the optical subdivision technique is without lambda/4 plates. It is less sensitive to environmental changes, it has prodigious potential to improve resolution farther and it can reduce polarization mixing error. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-frequency output power of 7.3 W at 2.09 mu m from a monolithic Ho:YAG nonplanar ring oscillator (NPRO) is demonstrated. Resonantly pumped by a Tm-doped fiber laser at 1.91 mu m, the Ho:YAG NPRO produces 71% of slope efficiency with respect to absorbed pump power and nearly diffraction-limited output with a beam quality parameter of M-2 approximate to 1.1. (c) 2008 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminum nitride (AlN) films were prepared on gamma-LiAlO2 substrates by radio frequency (rf) magnetron sputtering. The influence of substrate temperature (T-s) and nitrogen (N-2) concentration on film growth was investigated. The X-ray diffraction (XRD) results reveal that highly c-axis oriented AlN films can be obtained in the temperature range from room temperature (RT) to 300 degrees C. A smoother surface and a crystalline quality decrease with increasing N-2 concentration have been observed by XRD and atomic force microscopy (AFM) for the films deposited at lower substrate temperature. On the contrary, the degradation of the surface smoothness and the higher crystalline quality can be observed for the films deposited at a higher substrate temperature with N-2-rich ambient. The growth mechanism which leads to different crystalline quality of the films is discussed. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As doenças cardiovasculares possuem a maior taxa de óbitos no mundo, e notavelmente nos últimos anos as pesquisas genéticas sobre as mesmas estão baseadas em estudos de associação, no qual o gene suspeito que esteja em maior frequência entre os pacientes passa a ser considerado um possível fator causal. Os polimorfismos genéticos que ocorrem no receptor beta-adrenérgico podem resultar em mudanças significativas na função do receptor, podendo acarretar fisiopatologias. Neste trabalho, o objetivo foi estimar a diversidade e a frequência do polimorfismo Ser49Gly do gene do receptor beta-adrenérgico 1 a partir de uma amostra de 188 indivíduos da população do Estado do Rio de Janeiro. As frequências também foram analisadas a partir da estratificação da amostra por critério fenotípico em função do padrão de cor da pele em (negros e não negros) ou ancestralidade genética em (afrodescendente e não afrodescendente), definida através da informação dos marcadores de ancestralidade Indels e SNP de cromossomo Y, para avaliar se os padrões de ancestralidade ou cor da pele são fundamentais para a diferenciação e distanciamento genético. Fragmentos de interesse foram amplificados por PCR (reação de cadeia de polimerase) com primers específicos para o marcador Ser49Gly e as reações de genotipagem foram realizadas com enzimas de restrição Eco0109I. Os valores da heterozigosidade variaram entre 0,25-0,50 e 0,20-0,41 nos grupos estratificados por ancestralidade e cor da pele, respectivamente. No que diz respeito à análise do equilíbrio de Hardy-Weinberg, não houve um desvio significativo na distribuição do marcador nas amostras gerais do Estado do Rio de Janeiro, ou mesmo nas amostras estratificadas. A distribuição dos alelos na amostra dos 188 indivíduos da população geral do Rio de Janeiro (AC_RJ) mostrou uma frequência de 80,30% e 19,70% para o alelo selvagem e mutado Ser49Gly, respectivamente. A comparação das análises sobre a distribuição das frequências alélicas para este marcador mostrou a ocorrência de diferenças significativas na distribuição das frequências alélicas entre negros e não negros e afrodescendentes e não afrodescendentes. A diferença significativa observada entre os negros e afrodescendentes, foi em menor grau de distanciamento. A informação obtida em relação à ancestralidade foi crucial para a obtenção dos dados sobre o aumento da variável mutada do polimorfismo Ser49Gly nas populações negras e afrodescendentes do Estado Rio de Janeiro. Tal evidência, em combinação com estudos clínicos podem contribuir para uma análise pormenorizada do padrão de susceptibilidade à doença em questão, em falhas do mecanismo deste receptor.