966 resultados para NESTED PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the results of reverse transcription-polymerase chain reaction (RT-PCR) and traditional virus isolation on cell culture in detection of viral haemorrhagic septicaemia virus (VHSV) and infectious haematopoietic necrosis virus (IHNV). RT-PCR was used for 172 tissue sample pools (total of 859 fish) originating from a field survey on the occurrence of VHSV and IHNV in farmed and wild salmonids in Switzerland. These samples represented all sites with fish that were either identified as virus-positive by means of virus isolation (three sites, four positive tissue sample pools) and/or demonstrated positive anti-VHSV-antibody titres (83 sites, 121 positive blood samples) in a serum plaque neutralization test (SPNT). The RT-PCR technique confirmed the four VHSV-positive tissue sample pools detected by virus isolation and additionally identified one VHSV-positive sample that showed positive anti-VHSV-AB titres, but was negative in virus isolation. With IHNV, RT-PCR detected two positive samples not identified by virus isolation while in these fish the SPNT result had been questionable. One of the IHNV-positive samples represents the first detection of IHNV-RNA in wild brown trout in Switzerland. Compared to SPNT, the RT-PCR method detected, as with virus isolation, a much lower number of positive cases; reasons for this discrepancy are discussed. Our results indicate that RT-PCR can not only be successfully applied in field surveys, but may also be slightly more sensitive than virus isolation. However, in a titration experiment under laboratory conditions, the sensitivity of RT-PCR was not significantly higher when compared with virus isolation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Besnoitia besnoiti, an apicomplexan protozoan parasite, is the causative agent of bovine besnoitiosis. This infection may dramatically affect body condition, and, in males, lead to irreversible infertility. While identification of clinical cases and their histopathological confirmation is relatively simple to carry out, finding subclinical forms of infection is more difficult, thus a more sensitive test for the identification of the etiological agent may be an appropriate diagnostic tool. We have developed the ITS1 rDNA-sequence-based conventional and real-time PCR which are highly sensitive and specific for the detection of B. besnoiti infection in cattle. A recombinant internal positive control was introduced to assess possible sample-related inhibitory effects during the amplification reaction and, in order to prevent false-positive results, a pre-PCR treatment of potentially contaminating dU-containing PCR product with uracil-DNA-glycosylase (UDG) was followed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Typing of Clostridium perfringens strains by PCR-based determination of toxin genes proved to be a reliable method for diagnosis of enterotoxaemia in various animal species. We report the establishment and validation of three real-time fluorogenic (TaqMan) multiplex PCRs for the detection of C. perfringens alpha-, beta-, beta2-, epsilon-, entero- and iota-toxin genes. The composition of the PCRs was chosen with regard to robustness of the assays and in order to increase sensitivity compared to the conventional simplex PCRs. The combination of probe dyes selected for the real-time assays (FAM/TAMRA, Cy-5/BHQ-2 and VIC/TAMRA) as well as the designation of the chromosome-borne alpha-toxin as internal positive control allowed the creation of highly specific and sensitive, as well as time and cost effective PCRs. One hundred and three strains of C. perfringens isolated in Switzerland derived from clinical or suspected cases of enterotoxaemia in 10 different animal species were tested. The toxin genotypes were in agreement in both the conventional PCRs and the newly designed multiplex PCRs. Furthermore, the real-time PCR carried out as simplex allows to quantitate the copy numbers of plasmid-borne toxin genes in relation to the chromosomally located alpha-toxin gene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MATERIALS AND METHODS: In a pilot study, results of real-time broad-range (16S rRNA) polymerase chain reaction (PCR) performed on 45 blood samples of pediatric cancer patients with fever and neutropenia were compared with blood culture results. RESULTS: The PCR assay used, having proven a high sensitivity in artificially spiked blood samples, was positive in only three of ten blood culture-positive samples, and it was positive in 10 of 35 (29%) culture-negative samples. CONCLUSION: This broad-range PCR assay, which may identify not-grown bacteria potentially contributing to fever, needs improvement in sensitivity, and different reasons for positive PCR in negative blood culture samples need to be assessed before clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nonfluorescent low-cost, low-density oligonucleotide array was designed for detecting the whole coronavirus genus after reverse transcription (RT)-PCR. The limit of detection was 15.7 copies/reaction. The clinical detection limit in patients with severe acute respiratory syndrome was 100 copies/sample. In 39 children suffering from coronavirus 229E, NL63, OC43, or HKU1, the sensitivity was equal to that of individual real-time RT-PCRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early detection of bloodstream infections (BSI) is crucial in the clinical setting. Blood culture remains the gold standard for diagnosing BSI. Molecular diagnostic tools can contribute to a more rapid diagnosis in septic patients. Here, a multiplex real-time PCR-based assay for rapid detection of 25 clinically important pathogens directly from whole blood in <6 h is presented. Minimal analytical sensitivity was determined by hit rate analysis from 20 independent experiments. At a concentration of 3 CFU/ml a hit rate of 50% was obtained for E. aerogenes and 100% for S. marcescens, E. coli, P. mirabilis, P. aeruginosa, and A. fumigatus. The hit rate for C. glabrata was 75% at 30 CFU/ml. Comparing PCR identification results with conventional microbiology for 1,548 clinical isolates yielded an overall specificity of 98.8%. The analytical specificity in 102 healthy blood donors was 100%. Although further evaluation is warranted, our assay holds promise for more rapid pathogen identification in clinical sepsis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Culture-independent methods based on the 16S ribosomal RNA molecule are nowadays widely used for assessment of the composition of the intestinal microbiota, in relation to host health or probiotic efficacy. Because Bifidobacterium thermophilum was only recently isolated from human faeces until now, no specific real-time PCR (qPCR) assay has been developed for detection of this species as component of the bifidobacterial community of the human intestinal flora. RESULTS: Design of specific primers and probe was achieved based on comparison of 108 published bifidobacterial 16S rDNA sequences with the recently published sequence of the human faecal isolate B. thermophilum RBL67. Specificity of the primer was tested in silico by similarity search against the sequence database and confirmed experimentally by PCR amplification on 17 Bifidobacterium strains, representing 12 different species, and two Lactobacillus strains. The qPCR assay developed was linear for B. thermophilum RBL67 DNA quantities ranging from 0.02 ng/microl to 200 ng/microl and showed a detection limit of 10(5) cells per gram faeces. The application of this new qPCR assay allowed to detect the presence of B. thermophilum in one sample from a 6-month old breast-fed baby among 17 human faecal samples tested. Additionally, the specific qPCR primers in combination with selective plating experiments led to the isolation of F9K9, a faecal isolate from a 4-month old breast-fed baby. The 16S rDNA sequence of this isolate is 99.93% similar to that of B. thermophilum RBL67 and confirmed the applicability of the new qPCR assay in faecal samples. CONCLUSION: A new B. thermophilum-specific qPCR assay was developed based on species-specific target nucleotides in the 16S rDNA. It can be used to further characterize the composition of the bifidobacterial community in the human gastrointestinal tract. Until recently, B. thermophilum was considered as a species of animal origin, but here we confirm with the application of this new PCR assay the presence of B. thermophilum strains in the human gut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PCR tests for the rapid and valid detection of methicillin-resistant Staphylococcus aureus (MRSA) are now available. We evaluated the costs associated with contact screening for MRSA carriage in a tertiary-care hospital with low MRSA endemicity. Between 1 October 2005 and 28 February 2006, 232 patients were screened during 258 screening episodes (644 samples) for MRSA carriage by GenoType MRSA Direct (Hain Lifescience GmbH, Nehren, Germany). Conventional culture confirmed all PCR results. According to in-house algorithms, 34 of 258 screening episodes (14.7%) would have qualified for preemptive contact isolation, but such isolation was not done upon negative PCR results. MRSA carriage was detected in 4 (1.5%) of 258 screening episodes (i.e., in four patients), of which none qualified for preemptive contact isolation. The use of PCR for all 258 screening episodes added costs (in Swiss francs [CHF]) of CHF 104,328.00 and saved CHF 38,528.00 (for preemptive isolation). The restriction of PCR screening to the 34 episodes that qualified for preemptive contact isolation and screening all others by culture would have lowered costs for PCR to only CHF 11,988.00, a savings of CHF 38,528.00. Therefore, PCR tests are valuable for the rapid detection of MRSA carriers, but high costs require the careful evaluation of their use. In patient populations with low MRSA endemicity, the broad use of PCR probably is not cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used a PCR method to quantify the loads of Chlamydia trachomatis organisms in self-collected urine and vulvovaginal swab (VVS) samples from 93 women and 30 men participating in the Chlamydia Screening Studies Project, a community-based study of individuals not seeking health care. For women, self-collected VVS had a higher mean chlamydial load (10,405 organisms/ml; 95% confidence interval [95% CI], 5,167 to 21,163 organisms/ml) than did first-void urines (FVU) (503 organisms/ml; 95% CI, 250 to 1,022 organisms/ml; P < 0.001). Chlamydial loads in female and male self-collected FVU specimens were similar (P = 0.634). The mean chlamydial load in FVU specimens decreased with increasing age in females and males. There was no strong statistical evidence of differences in chlamydial load in repeat male and female FVU specimens taken when patients attended for treatment a median of 23.5 (range, 14 to 62) and 28 (range, 13 to 132) days later, respectively, or in VVS taken a median of 35 (range, 14 to 217) days later. In this study, chlamydial load values for infected persons in the community who were not seeking treatment were lower than those published in other studies involving symptomatic patients attending clinical settings. This might have implications for estimates of the infectiousness of chlamydia. The results of this study provide a scientific rationale for preferring VVS to FVU specimens from women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reliable quantification of gene copy number variations is a precondition for future investigations regarding their functional relevance. To date, there is no generally accepted gold standard method for copy number quantification, and methods in current use have given inconsistent results in selected cohorts. In this study, we compare two methods for copy number quantification. beta-defensin gene copy numbers were determined in parallel in 80 genomic DNA samples by real-time PCR and multiplex ligation-dependent probe amplification (MLPA). The pyrosequencing-based paralog ratio test (PPRT) was used as a standard of comparison in 79 out of 80 samples. Realtime PCR and MPLA results confirmed concordant DEFB4, DEFB103A, and DEFB104A copy numbers within samples. These two methods showed identical results in 32 out of 80 samples; 29 of these 32 samples comprised four or fewer copies. The coefficient of variation of MLPA is lower compared with PCR. In addition, the consistency between MLPA and PPRT is higher than either PCR/MLPA or PCR/PPRT consistency. In summary, these results suggest that MLPA is superior to real-time PCR in beta-defensin copy number quantification.