918 resultados para Chirurgie


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial sepsis is a severe clinical condition, leading to severe sepsis, septic shock, and death. The complex pathophysiology of sepsis is not yet fully understood. Cytokines, released by immune cells such as macrophages, play an important role in the pathophysiology of sepsis. Kupffer cells are the largest population of macrophages in the body. Purinergic signaling, mediated by different nucleosides and nucleotides, and purinergic receptors, has been shown to have various effects on cytokine release, inflammatory processes and the immune system. In our work with in vitro experiments we studied the effect of extracellular nucleotides on the release of TNFα by primary murine Kupffer cells, and the effect of extracellular nucleotides on the phagocytosis of murine RAW 264.7 and human U-937 cell culture macrophages. Secretion of TNFα was measured using ELISA, phagocytosis of bio particles was measured using a plate reader phagocytosis assay and flow cytometry. Our experiments show, that extracellular LPS stimulate release of TNFα in murine Kupffer cells and that extracellular nucleotides inhibit this effect in a dose dependent matter. Our other experiments show phagocytosis of fluorescence labeled bio particles by both macrophage cell lines RAW 264.7 and U-937 in a dose dependent manner. The experiments could not show an effect of extracellular nucleotides on phagocytosis of cell culture macrophages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Persistent traumatic peroneal nerve palsy, following nerve surgery failure, is usually treated by tendon transfer or more recently by tibial nerve transfer. However, when there is destruction of the tibial anterior muscle, an isolated nerve transfer is not possible. In this article, we present the key steps and surgical tips for the Ninkovic procedure including transposition of the neurotized lateral gastrocnemius muscle with the aim of restoring active voluntary dorsiflexion. SURGICAL TECHNIQUE The transposition of the lateral head of the gastrocnemius muscle to the tendons of the anterior tibial muscle group, with simultaneous transposition of the intact proximal end of the deep peroneal nerve to the tibial nerve of the gastrocnemius muscle by microsurgical neurorrhaphy is performed in one stage. It includes 10 key steps which are described in this article. Since 1994, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We review the indications and limitations of the technique. CONCLUSION Early clinical results after neurotized lateral gastrocnemius muscle transfer appear excellent; however, they still need to be compared with conventional tendon transfer procedures. Clinical studies are likely to be conducted in this area largely due to the frequency of persistant peroneal nerve palsy and the limitations of functional options in cases of longstanding peripheral nerve palsy, anterior tibial muscle atrophy or destruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Background: Preservation of cardiac grafts for transplantation is not standardized and most centers use a single administration of crystalloid solution at the time of harvesting. We investigated possible benefits of an additional dose of cardioplegia dispensed immediately before implantation. – – Methods: Consecutive adult cardiac transplantations (2005?2012) were reviewed. Hearts were harvested following a standard protocol (Celsior 2L, 4?8°C). In 2008, 100 ml crys-talloid cardioplegic solution was added and administered immediately before implanta-tion. Univariate and logistic regression analyses were used to investigate risk factors for post-operative graft failure and mid-term outcome. – – Results: A total of 81 patients, 44 standard (?Cardio???) vs. 37 with additional cardiople-gia (?CardioC?) were analyzed. Recipients and donors were comparable in both groups. CardioC patients demonstrated a reduced need for defibrillation (24 vs. 48%, p D0.03), post-operative ratio of CK-MB/CK (10.1_3.9 vs. 13.3_4.2%, p D0.001), intubation time (2.0_1.6 vs. 7.2_11.5 days, p D0.05), and ICU stay (3.9_2.1 vs. 8.5_7.8 days, p D0.001). Actuarial survival was reduced when graft ischemic time was >180 min in Cardio?? but not in CardioC patients (p D0.033). Organ ischemic time >180 min (OR: 5.48, CI: 1.08?27.75), donor female gender (OR: 5.84, CI: 1.13?33.01), and recipient/donor age >60 (OR: 6.33, CI: 0.86?46.75), but not the additional cardioplegia or the observation period appeared independent predictors of post-operative acute graft failure. – – Conclusion: An additional dose of cardioplegia administered immediately before implan-tation may be a simple way to improve early and late outcome of cardiac transplantation, especially in situations of prolonged graft ischemia.A large, ideally multicentric, randomized study is desirable to verify this preliminary observation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: OBJECTIVES: – The number of heart transplantations is limited by donor organ availability. Donation after circulatory determination of death (DCDD) could significantly improve graft availability, however, organs undergo warm ischaemia followed by reperfusion, leading to tissue damage. Laboratory studies suggest that mechanical postconditioning [(MPC), brief, intermittent periods of ischaemia at the onset of reperfusion] can limit reperfusion injury, however, clinical translation has been disappointing. We hypothesized that MPC-induced cardioprotection depends on fatty acid levels at reperfusion. – – METHODS: – Experiments were performed with an isolated rat heart model of DCDD. Hearts of male Wistar rats (n = 42) underwent working-mode perfusion for 20 min (baseline), 27 min of global ischaemia and 60 min reperfusion with or without MPC (two cycles of 30 s reperfusion/30 s ischaemia) in the presence or absence of high fat [(HF), 1.2 mM palmitate]. Haemodynamic parameters, necrosis factors and oxygen consumption (O2C) were assessed. Recovery rate was calculated as the value at 60 min reperfusion expressed as a percentage of the mean baseline value. The Kruskal-Wallis test was used to provide an overview of differences between experimental groups, and pairwise comparisons were performed to compare specific time points of interest for parameters with significant overall results. – – RESULTS: – Percent recovery of left ventricular (LV) work [developed pressure (DP)-heart rate product] at 60 min reperfusion was higher in hearts reperfused without fat versus with fat (58 ± 8 vs 23 ± 26%, P < 0.01) in the absence of MPC. In the absence of fat, MPC did not affect post-ischaemic haemodynamic recovery. Among the hearts reperfused with HF, two significantly different subgroups emerged according to recovery of LV work: low recovery (LoR) and high recovery (HiR) subgroups. At 60 min reperfusion, recovery was increased with MPC versus no MPC for LV work (79 ± 6 vs 55 ± 7, respectively, P < 0.05) in HiR subgroups and for DP (40 ± 27 vs 4 ± 2%), dP/dtmax (37 ± 24 vs 5 ± 3%) and dP/dtmin (33 ± 21 vs 5 ± 4%, P < 0.01 for all) in LoR subgroups. – – CONCLUSIONS: – Effects of MPC depend on energy substrate availability, MPC increased recovery of LV work in the presence, but not in the absence, of HF. Controlled reperfusion may be useful for therapeutic strategies aimed at improving post-ischaemic recovery of cardiac DCDD grafts, and ultimately in increasing donor heart availability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurde die Sicherheit und Zuverlässigkeit der Nebenschilddrüsenchirurgie beim Hyperparathyreoidismus mit intraoperativer Bestimmung des intakten Parathormons (Parathormonschnelltest) untersucht. Im Zeitrahmen zwischen 1/2004 und 12/2008 wurden an der universitären Klinik für viszerale Chirurgie und Medizin bei 194 operierten Patienten 150 Adenome, 39 Hyperplasien, sowie 5 Doppeladenome der Nebenschilddrüsen gefunden. Das intakte Parathormons (iPTH) im Serum wurde zu Beginn der Operation, nach Präparation der vergrösserten Nebenschilddrüse bei noch erhaltenem Gefässstiel, sowie 5, 10 und 15 Minuten nach der Parathyreoidektomie gemessen. Für den Erfolg der Operation wurde ein Abfall des iPTH um mehr als 50% vom Ausgangswert innerhalb der ersten 5 Minuten, sowie um mehr als 60% innerhalb der ersten 10 Minuten festgelegt. Bei solitären Adenomen der Nebenschilddrüse kam es bereits 5 Minuten nach der Parathyreoidektomie zu einem durchschnittlichen Abfall des iPTH um 61±19% vom Ausgangswert und nach 10 Minuten um 73±17%. Bei einer Hyperplasie der Nebenschilddrüse blieb dieser schnell eintretende steile Abfall des iPHT aus, der Rückgang des iPHT-Spiegels war zögerlich und erreichte erst nach subtotaler Parathyreoidektomie Normalwerte. In dem vorliegenden Patientengut wurden drei falsch-negative sowie ein falsch-positiver Befund beobachtet. Prognostisch ergibt sich für ein solitäres Adenom unserem Patientengut eine Sensitivität von 96% und eine Spezifität von 91% für den 10 Minuten-Wert. Der prädiktive Wert des positiven Tests beträgt 97%. Die vorliegende Arbeit zeigt, dass mit Hilfe der intraoperativen iPTH-Messung die Sicherheit in der Chirurgie des Parathyreoidismus gesteigert werden kann, vor allem beim Vorliegen eines Doppeladenoms oder bei schwierigen Rezidiveingriffen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Minimized Extracorporeal Circulation does not impair cognitive brain function after coronary artery bypass grafting – – Objectives – Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary bypass grafting (CABG) by Electroencephalogram (EEG) P 300 wave event related potentials (ERP) and number connection test ( NCT) as metrics of cognitive function. – – Methods – Cognitive brain function was assessed in 31 patients with a mean age of 65y (Standard Deviation/SD 10) undergoing coronary artery bypass grafting (CABG) by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds [ms]) directly prior to intervention, 7 days after and 3 month later. Number connection test (NCT), serving as method of control, was performed simultaneously in all patients. – – Results – Seven days following CABG, cognitive P300 evoked potentials were comparable to preoperative baseline values (vertex [Cz] 376 (SD 11) ms vs. 378 (18) ms, p=0.39, frontal [Fz] 377 (11) vs. 379 (21) ms, p=0.53). Cognitive brain function showed at 3 months compared to baseline values ([Cz] 376 (11) ms vs. 371 (14 ms) p=0.09, [Fz] 377 (11) ms vs. 371 (15) ms, p=0.04. Between the first postoperative measurement and 3 months later, significant improvement was observed ([Cz] 378 (18) ms vs. 371 (14) ms, p=0.03, [Fz] 379 (21) vs. 371 (15) ms, p=0.02). Similar clearly corresponding patterns could be obtained via number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (p = 0.05) and (Fz) results (p = 0.04). – – Conclusions