932 resultados para Blood-brain-barrier


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucocorticoid hormones are critical to respond and adapt to stress. Genetic variations in the glucocorticoid receptor (GR) gene alter hypothalamic-pituitary-adrenal (HPA) axis activity and associate with hypertension and susceptibility to metabolic disease. Here we test the hypothesis that reduced GR density alters blood pressure and glucose and lipid homeostasis and limits adaption to obesogenic diet. Heterozygous GR βgeo/+ mice were generated from embryonic stem (ES) cells with a gene trap integration of a β-galactosidase-neomycin phosphotransferase (βgeo) cassette into the GR gene creating a transcriptionally inactive GR fusion protein. Although GRβgeo/+ mice have 50% less functional GR, they have normal lipid and glucose homeostasis due to compensatory HPA axis activation but are hypertensive due to activation of the renin-angiotensin- aldosterone system (RAAS). When challenged with a high-fat diet, weight gain, adiposity, and glucose intolerance were similarly increased in control and GRβgeo/+ mice, suggesting preserved control of intermediary metabolism and energy balance. However, whereas a high-fat diet caused HPA activation and increased blood pressure in control mice, these adaptions were attenuated or abolished in GRβgeo/+ mice. Thus, reduced GR density balanced by HPA activation leaves glucocorticoid functions unaffected but mineralocorticoid functions increased, causing hypertension. Importantly, reduced GR limits HPA and blood pressure adaptions to obesogenic diet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because moving depictions of face emotion have greater ecological validity than their static counterparts, it has been suggested that still photographs may not engage ‘authentic’ mechanisms used to recognize facial expressions in everyday life. To date, however, no neuroimaging studies have adequately addressed the question of whether the processing of static and dynamic expressions rely upon different brain substrates. To address this, we performed an functional magnetic resonance imaging (fMRI) experiment wherein participants made emotional expression discrimination and Sex discrimination judgements to static and moving face images. Compared to Sex discrimination, Emotion discrimination was associated with widespread increased activation in regions of occipito-temporal, parietal and frontal cortex. These regions were activated both by moving and by static emotional stimuli, indicating a general role in the interpretation of emotion. However, portions of the inferior frontal gyri and supplementary/pre-supplementary motor area showed task by motion interaction. These regions were most active during emotion judgements to static faces. Our results demonstrate a common neural substrate for recognizing static and moving facial expressions, but suggest a role for the inferior frontal gyrus in supporting simulation processes that are invoked more strongly to disambiguate static emotional cues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methylene chloride (dichloromethane) is widely used as a solvent for stripping of paint, as industrial cleaning agent, for coating of pills in the pharmaceutical industry, and in the decaffeination of coffee. There is “sufficient evidence for the carcinogenicity” of methylene chloride in animals and “inadequate evidence for its carcinogenity in humans”, according to IARC (IARC 1987; CEC 1990).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method has been developed for the quantification of 2-hydroxyethylated cysteine resulting as adduct in blood proteins after human exposure to ethylene oxide, by reversed-phase HPLC with fluorometric detection. The specific adduct is analysed in albumin and in globin. After isolation of albumin and globin from blood, acid hydrolysis of the protein and precolumn derivatisation of the digest with 9-fluorenylmethoxycarbonylchloride, the levels of derivatised S-hydroxyethylcysteine are analysed by RP-HPLC and fluorescence detection, with a detection limit of 8 nmol/g protein. Background levels of S-hydroxyethylcysteine were quantified in both albumin and globin, under special consideration of the glutathione transferase GSTT1 and GSTM1 polymorphisms. GSTT1 polymorphism had a marked influence on the physiological background alkylation of cysteine. While S-hydroxyethylcysteine levels in "non-conjugators" were between 15 and 50 nmol/g albumin, "low conjugators" displayed levels between 8 and 21 nmol/g albumin, and "high conjugators" did not show levels above the detection limit. The human GSTM1 polymorphism had no apparent effect on background levels of blood protein 2-hydroxyethylation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schottky barrier solar cells based on graphene/n-silicon heterojunction have been fabricated and characterized and the effect of graphene molecular doping by HNO3 on the solar cells performances have been analyzed. Different doping conditions and thermal annealing processes have been tested to asses and optimize the stability of the devices. The PCE of the cells increases after the treatment by HNO3 and reaches 5% in devices treated at 200 °C immediately before the exposition to the oxidant. Up to now our devices retain about 80% of efficiency over a period of two weeks, which represents a good stability result for similar devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Current blood based diagnostic assays to detect heart failure (HF) have large intra-individual and inter-individual variations which have made it difficult to determine whether the changes in the analyte levels reflect an actual change in disease activity. Human saliva mirrors the body's health and well being and similar to 20% of proteins that are present in blood are also found in saliva. Saliva has numerous advantages over blood as a diagnostic fluid which allows for a non-invasive, simple, and safe sample collection. The aim of our study was to develop an immunoassay to detect NT-proBNP in saliva and to determine if there is a correlation with blood levels. Methods: Saliva samples were collected from healthy volunteers (n = 40) who had no underlying heart conditions and HF patients (n = 45) at rest. Samples were stored at -80 degrees C until analysis. A customised homogeneous sandwich AlphaLISA((R)) immunoassay was used to quantify NT-proBNP levels in saliva. Results: Our NT-proBNP immunoassay was validated against a commercial Roche assay on plasma samples collected from HF patients (n = 37) and the correlation was r(2) = 0.78 (p<0.01, y = 1.705 x +1910.8). The median salivary NT-proBNP levels in the healthy and HF participants were <16 pg/mL and 76.8 pg/mL, respectively. The salivary NT-proBNP immunoassay showed a clinical sensitivity of 82.2% and specificity of 100%, positive predictive value of 100% and negative predictive value of 83.3%, with an overall diagnostic accuracy of 90.6%. Conclusion: We have firstly demonstrated that NT-proBNP can be detected in saliva and that the levels were higher in heart failure patients compared with healthy control subjects. Further studies will be needed to demonstrate the clinical relevance of salivary NT-proBNP in unselected, previously undiagnosed populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human saliva mirrors body’s health and well-being and many of the biomolecules present in blood or urine can also be found in salivary secretions. However, biomolecular concentrations in saliva are usually one tenth to one thousandth of the levels in blood (Pfaffe et al., 2011). Sensitive detection technology platforms are therefore required to detect biomolecules in saliva. Another road block to the advancement of salivary diagnostics is the lack of information related to healthy state saliva vs. a diseased saliva, baseline levels and reference ranges and diurnal variations. Saliva has numerous advantages over blood or urine as a diagnostic fluid: (a) the non-invasive nature of sample collection and the simple, safe, painless and cost-effective methods to collect it; (b) unskilled personnel can collect saliva samples at multiple time points; and (c) the total protein concentration is approximately a quarter of that is present in plasma, which makes it easier to investigate low abundance proteins (Pfaffe et al., 2011). Currently, saliva assays are routinely used to determine, diseases such as HIV, drugs and substances of abuse to provide information on exposure and give qualitative information on the type of illicit drug used (Kintz et al., 2009), cortisol levels for diagnosing Cushing’s syndrome (Doi et al., 2008), and use for biomonitoring of exposure to chemicals (Caporossi et al., 2010) to measure hormones (Gröschl, 2009)....

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deoxyribonucleic acid (DNA) extraction has considerably evolved since it was initially performed back in 1869. It is the first step required for many of the available downstream applications used in the field of molecular biology. Whole blood samples are one of the main sources used to obtain DNA, and there are many different protocols available to perform nucleic acid extraction on such samples. These methods vary from very basic manual protocols to more sophisticated methods included in automated DNA extraction protocols. Based on the wide range of available options, it would be ideal to determine the ones that perform best in terms of cost-effectiveness and time efficiency. We have reviewed DNA extraction history and the most commonly used methods for DNA extraction from whole blood samples, highlighting their individual advantages and disadvantages. We also searched current scientific literature to find studies comparing different nucleic acid extraction methods, to determine the best available choice. Based on our research, we have determined that there is not enough scientific evidence to support one particular DNA extraction method from whole blood samples. Choosing a suitable method is still a process that requires consideration of many different factors, and more research is needed to validate choices made at facilities around the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To complement the existing treatment guidelines for all tumour types, ESMO organises consensus conferences to focus on specific issues in each type of tumour. The 2nd ESMO Consensus Conference on Lung Cancer was held on 11-12 May 2013 in Lugano. A total of 35 experts met to address several questions on non-small-cell lung cancer (NSCLC) in each of four areas: pathology and molecular biomarkers, first-line/second and further lines in advanced disease, early stage disease and locally-advanced disease. For each question, recommendations were made including reference to the grade of recommendation and level of evidence. This consensus paper focuses on 1st line / 2nd and further lines of treatment in advanced disease. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface-enhanced Raman spectroscopy (SERS) is a potentially important tool in the rapid and accurate detection of pathogenic bacteria in biological fluids. However, for diagnostic application of this technique, it is necessary to develop a highly sensitive, stable, biocompatible and reproducible SERS-active substrate. In this work, we have developed a silver–gold bimetallic SERS surface by a simple potentiostatic electrodeposition of a thin gold layer on an electrochemically roughened nanoscopic silver substrate. The resultant substrate was very stable under atmospheric conditions and exhibited the strong Raman enhancement with the high reproducibility of the recorded SERS spectra of bacteria (E. coli, S. enterica, S. epidermidis, and B. megaterium). The coating of the antibiotic over the SERS substrate selectively captured bacteria from blood samples and also increased the Raman signal in contrast to the bare surface. Finally, we have utilized the antibiotic-coated hybrid surface to selectively identify different pathogenic bacteria, namely E. coli, S. enterica and S. epidermidis from blood samples.