965 resultados para limit of detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report the development of a sensitive label-free impedimetric biosensor based on the use of affibody as bioreceptor and gold nanostructured screen-printed graphite as a sensor platform for the detection of human epidermal growth factor receptor 2 (HER2). The affisensor is realized by immobilizing a terminal cysteine-modified affibody on gold nanoparticles. The sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Furthermore, surface plasmon resonance (SPR) technology was also applied to explore the potential of affibodies as small-molecule discriminating tools. Using optimized experimental conditions, a single-use affisensor showed a good analytical performance for HER2 detection from 0 to 40μg/L. The estimated limit of detection was 6.0μg/L. Finally, the realized affisensor was applied to human serum samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the work underlying this thesis solid-phase microextraction (SPME) was evaluated as a passive sampling technique for organophosphate triesters in indoor air. These compounds are used on a large scale as flame-retarding and plastizicing additives in a variety of materials and products, and have proven to be common pollutants in indoor air. The main objective of this work was to develop an accurate method for measuring the volatile fraction. Such a method can be used in combination with active sampling to obtain information regarding the vapour/particulate distribution in different indoor environments. SPME was investigated under both equilibrium and non-equilibrium conditions and parameters associated with these different conditions were estimated. In Paper I, time-weighted average (TWA) SPME under dynamic conditions was investigated in order to obtain a fast air sampling method for organophosphate triesters. Among the investigated SPME coatings, the absorptive PDMS polymer had the highest affinity for the organophosphate triesters and was consequently used in all further work. Since the sampling rate is dependent on the agitation conditions, the linear airflow rates had to be carefully considered. Sampling periods as short as 1 hour were shown to be sufficient for measurements in the ng-μg m-3 range when using a PDMS 100-μm fibre and a linear flow rate above 7 cm s-1 over the fibre. SPME under equilibrium conditions is rather time-consuming, even under dynamic conditions, for slowly partitioning compounds such as organophosphate triesters. Nevertheless, this method has some significant advantages. For instance, the limit of detection is much lower compared to 1 h TWA sampling. Furthermore, the sampling time can be ignored as long as equilibrium has been attained. In Paper II, SPME under equilibrium conditions was investigated and evaluated for organophosphate triester vapours. Since temperature and humidity are closely associated with the distribution constant a simple study of the effect of these parameters was performed. The obtained distribution constants were used to determine the air levels in a common indoor environment. SPME and parallel active sampling on filters yielded similar results, indicating that the detected compounds were almost entirely associated with the vapour phase To apply dynamic SPME method in the field a sampler device, which enables controlled linear airflow rates to be applied, was constructed and evaluated (Paper III). This device was developed for application of SPME and active sampling in parallel. A GC/PICI-MS/MS method was developed and used in combination with active sampling of organophosphate triesters in indoor air (Paper IV). The combination of MS/MS and the soft ionization achieved with methanol as reagent gas yielded high selectivity and detection limits comparable to those provided by GC with nitrogen-phosphorus detection (NPD). The method limit of detection, when sampling 1.5 m3 of air, was in the range 0.1-1.4 ng m-3. In Paper V, the developed MS method was used in combination with SPME for indoor air measurements. The levels detected in the investigated indoor environments range from a few ng to μg m-3. Tris(2-chloropropyl) phosphate was detected at a concentration as high as 7 μg m-3 in a newly rebuilt lecture room.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach for the determination of free and total valproic acid in small samples of 140 μL human plasma based on capillary electrophoresis with contactless conductivity detection is proposed. A dispersive liquid-liquid microextraction technique was employed in order to remove biological matrices prior to instrumental analysis. The free valproic acid was determined by isolating free valproic acid from protein-bound valproic acid by ultrafiltration under centrifugation of 100 μL sample. The filtrate was acidified to turn valproic acid into its protonated neutral form and then extracted. The determination of total valproic acid was carried out by acidifying 40 μL untreated plasma to release the protein-bound valproic acid prior to extraction. A solution consisting of 10 mM histidine, 10 mM 3-(N-morpholino)propanesulfonic acid and 10 μM hexadecyltrimethylammonium bromide of pH 6.5 was used as background electrolyte for the electrophoretic separation. The method showed good linearity in the range of 0.4-300 μg/mL with a correlation coefficient of 0.9996. The limit of detection was 0.08 μg/mL, and the reproducibility of the peak area was excellent (RSD=0.7-3.5%, n=3, for the concentration range from 1 to 150 μg/mL). The results for the free and total valproic acid concentration in human plasma were found to be comparable to those obtained with a standard immunoassay. The corresponding correlation coefficients were 0.9847 for free and 0.9521 for total valproic acid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A nonfluorescent low-cost, low-density oligonucleotide array was designed for detecting the whole coronavirus genus after reverse transcription (RT)-PCR. The limit of detection was 15.7 copies/reaction. The clinical detection limit in patients with severe acute respiratory syndrome was 100 copies/sample. In 39 children suffering from coronavirus 229E, NL63, OC43, or HKU1, the sensitivity was equal to that of individual real-time RT-PCRs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trichinellosis is a zoonotic disease that is caused by the nematode Trichinella spp. Both European Union regulations and guidelines from the World Organization for Animal Health foresee the possibility of conducting serological surveillance for Trichinella spp. A newly developed commercial enzyme-linked immunosorbent assay (ELISA) was evaluated against 2 existing diagnostic techniques: an in-house ELISA and an in-house Western blot. A total of 875 Trichinella larva-negative samples of pigs and 93 Trichinella larva-positive samples of both naturally and experimentally infected pigs were included in the study. Bayesian modeling techniques were used to correct for the absence of a perfect reference test. The sensitivity and specificity of the commercial ELISA was 97.1-97.8% and 99.5-99.8%, respectively. Sensitivity analysis demonstrated high stability in the models. In a serological surveillance system, ELISA-positive samples should be tested by a confirmatory test. The Western blot is a suitable test for this purpose. With the use of the results of the models, the sensitivity and specificity of a test protocol in both ELISA and Western blot were 95.9% and 99.9%, respectively. The high sensitivity and specificity were achieved with a lower limit of detection than that of the routine artificial digestion test, suggesting that serological surveillance is a valuable alternative in surveillance for Trichinella spp. in pig production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

F. psychrophilum is the causative agent of Bacterial Cold Water Disease (BCW) and Rainbow Trout Fry Syndrome (RTFS). To date, diagnosis relies mainly on direct microscopy or cultural methods. Direct microscopy is fast but not very reliable, whereas cultural methods are reliable but time-consuming and labor-intensive. So far fluorescent in situ hybridization (FISH) has not been used in the diagnosis of flavobacteriosis but it has the potential to rapidly and specifically detect F. psychrophilum in infected tissues. Outbreaks in fish farms, caused by pathogenic strains of Flavobacterium species, are increasingly frequent and there is a need for reliable and cost-effective techniques to rapidly diagnose flavobacterioses. This study is aimed at developing a FISH that could be used for the diagnosis of F. psychrophilum infections in fish. We constructed a generic probe for the genus Flavobacterium ("Pan-Flavo") and two specific probes targeting F. psychrophilum based on 16S rRNA gene sequences. We tested their specificity and sensitivity on pure cultures of different Flavobacterium and other aquatic bacterial species. After assessing their sensitivity and specificity, we established their limit of detection and tested the probes on infected fresh tissues (spleen and skin) and on paraffin-embedded tissues. The results showed high sensitivity and specificity of the probes (100% and 91% for the Pan-Flavo probe and 100% and 97% for the F. psychrophilum probe, respectively). FISH was able to detect F. psychrophilum in infected fish tissues, thus the findings from this study indicate this technique is suitable as a fast and reliable method for the detection of Flavobacterium spp. and F. psychrophilum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commercially available assays for the simultaneous detection of multiple inflammatory and cardiac markers in porcine blood samples are currently lacking. Therefore, this study was aimed at developing a bead-based, multiplexed flow cytometric assay to simultaneously detect porcine cytokines [interleukin (IL)-1β, IL-6, IL-10, and tumor necrosis factor alpha], chemokines (IL-8 and monocyte chemotactic protein 1), growth factors [basic fibroblast growth factor (bFGF), vascular endothelial growth factor, and platelet-derived growth factor-bb], and injury markers (cardiac troponin-I) as well as complement activation markers (C5a and sC5b-9). The method was based on the Luminex xMAP technology, resulting in the assembly of a 6- and 11-plex from the respective individual singleplex situation. The assay was evaluated for dynamic range, sensitivity, cross-reactivity, intra-assay and interassay variance, spike recovery, and correlation between multiplex and commercially available enzyme-linked immunosorbent assay as well as the respective singleplex. The limit of detection ranged from 2.5 to 30,000 pg/ml for all analytes (6- and 11-plex assays), except for soluble C5b-9 with a detection range of 2-10,000 ng/ml (11-plex). Typically, very low cross-reactivity (<3% and <1.4% by 11- and 6-plex, respectively) between analytes was found. Intra-assay variances ranged from 4.9 to 7.4% (6-plex) and 5.3 to 12.9% (11-plex). Interassay variances for cytokines were between 8.1 and 28.8% (6-plex) and 10.1 and 26.4% (11-plex). Correlation coefficients with singleplex assays for 6-plex as well as for 11-plex were high, ranging from 0.988 to 0.997 and 0.913 to 0.999, respectively. In this study, a bead-based porcine 11-plex and 6-plex assay with a good assay sensitivity, broad dynamic range, and low intra-assay variance and cross-reactivity was established. These assays therefore represent a new, useful tool for the analysis of samples generated from experiments with pigs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leptospirosis is a global zoonotic disease. Pathogenic Leptospira species, the causative agent of leptospirosis, colonize the renal tubules of chronically infected maintenance hosts such as dogs, rats and cattle. Maintenance hosts typically remain clinically asymptomatic and shed leptospires into the environment via urine. In contrast, accidental hosts such as humans can suffer severe acute forms of the disease. Infection results from direct contact with infected urine or indirectly, through contaminated water sources. In this study, a quantitative real-time PCR specific for lipL32 was designed to detect the urinary shedding of leptospires from dogs. The sensitivity and specificity of the assay was evaluated using both a panel of pathogenic Leptospira species and clinical microbial isolates, and samples of urine collected from experimentally infected rats and non-infected controls. The lower limit of detection was approximately 3 genome equivalents per reaction. The assay was applied to canine urine samples collected from local dog sanctuaries and the University Veterinary Hospital (UVH) at University College Dublin. Of 525 canine urine samples assayed, 37 were positive, indicating a prevalence of urinary shedding of leptospires of 7.05%. These results highlight the need to provide effective canine vaccination strategies and raise public health awareness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detection of malarial sporozoites by a double antibody sandwich enzyme linked immunosorbent assay (ELISA) is described. This investigation utilized the Anopheles stephensi-Plasmodium berghei malaria model for the generation of sporozoites. Anti-sporozoite antibody was obtained from the sera of rats which had been bitten by An. stephensi with salivary gland sporozoites. Mosquitoes were irradiated prior to feeding on the rats to render the sporozoites non-viable.^ The assay employed microtiter plates coated with their rat anti-sporozoite antiserum or rat anti-sporozoite IgG. Intact and sonicated sporozoites were used as antigens. Initially, sporozoites were detected by an ELISA using staphylococcal protein A conjugated with alkaline phosphatase. Sporozoites were also detected using alkaline phosphatase or horseradish peroxidase conjugated to anti-sporozoite IgG. Best results were obtained using the alkaline phosphatase conjugate.^ This investigation included the titration of antigen, coating antibody and labelled antibody as well as studies of various incubation times. A radioimmunoassay (RIA) was also developed and compared with the ELISA for detecting sporozoites. Finally, the detection of a single infected mosquito in pools of 5 to 10 whole, uninfested ones was studied using both ELISA and RIA.^ Sonicated sporozoites were more readily detected than intact sporozoites. The lower limit of detection was approximately 500 sporozoites per ml. Results using ELISA or RIA were similar. The ability of the ELISA to detect a single infected mosquito in a pool of uninfected ones indicates that this technique has potential use in entomological field studies which aim at determining the vector status of anopheline mosquitoes. The potential of the ELISA for identifying sporozoites of different species of malaria is discussed. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The challenge of the Human Genome Project is to increase the rate of DNA sequence acquisition by two orders of magnitude to complete sequencing of the human genome by the year 2000. The present work describes a rapid detection method using a two-dimensional optical wave guide that allows measurement of real-time binding or melting of a light-scattering label on a DNA array. A particulate label on the target DNA acts as a light-scattering source when illuminated by the evanescent wave of the wave guide and only the label bound to the surface generates a signal. Imaging/visual examination of the scattered light permits interrogation of the entire array simultaneously. Hybridization specificity is equivalent to that obtained with a conventional system using autoradiography. Wave guide melting curves are consistent with those obtained in the liquid phase and single-base discrimination is facile. Dilution experiments showed an apparent lower limit of detection at 0.4 nM oligonucleotide. This performance is comparable to the best currently known fluorescence-based systems. In addition, wave guide detection allows manipulation of hybridization stringency during detection and thereby reduces DNA chip complexity. It is anticipated that this methodology will provide a powerful tool for diagnostic applications that require rapid cost-effective detection of variations from known sequences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a highly sensitive, high Q-factor, label free and selective glucose sensor by using excessively tilted fiber grating (Ex-TFG) inscribed in the thin-cladding optical fiber (TCOF). Glucose oxidase (GOD) was covalently immobilized on optical fiber surface and the effectiveness of GOD immobilization was investigated by the fluorescence microscopy and highly accurate spectral interrogation method. In contrast to the long period grating (LPG) and optical fiber (OF) surface Plasmon resonance (SPR) based glucose sensors, the Ex-TFG configuration has merits of nearly independent cross sensitivity of the environmental temperature, simple fabrication method (no noble metal deposition or cladding etching) and high detection accuracy (or Q-factor). Our experimental results have shown that Ex-TFG in TCOF based sensor has a reliable and fast detection for the glucose concentration as low as 0.1~2.5mg/ml and a high sensitivity of ~1.514nm·(mg/ml)−1, which the detection accuracy is ~0.2857nm−1 at pH 5.2, and the limit of detection (LOD) is 0.013~0.02mg/ml at the pH range of 5.2~7.4 by using an optical spectrum analyzer with a resolution of 0.02nm.