281 resultados para distraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of this prospective study on humans were to evaluate (a) the clinical outcome of alveolar distraction osteogenesis for the correction of vertically deficient edentulous mandibular ridges, (b) the clinical outcome of dental implants placed in the distracted areas, and (c) the quality and quantity of the bone that had formed in the distraction gap. MATERIAL AND METHODS: Seven patients presenting vertically deficient edentulous ridges were treated by means of distraction osteogenesis with an intraoral alveolar distractor. Approximately 3 months after consolidation of the distracted segments, 20 ITI solid screw SLA implants were placed in the distracted areas. Three to 4 months later, abutments were connected and prosthetic loading of the implants started. During implant site preparation, bone biopsies were taken at the implant sites with trephine burrs for histologic and histometric analyses. RESULTS: The mean follow-up after the initial prosthetic loading was 18 months (range 12-24 months). The mean bone gain obtained at the end of distraction was 7 mm (range 5-9 mm). The cumulative success rate of implants 2 years after the onset of prosthetic loading was 95%, whereas the survival rate of implants was 100%. The newly formed bone consisted of woven bone reinforced by parallel-fibered bone with bone marrow spaces between the bone trabeculae. The bone area fraction in the distraction region ranged from 21.6% to 57.8% (38.5+/-11.7%). DISCUSSION AND CONCLUSIONS: Results from this study showed that (a) distraction osteogenesis is a reliable technique for the correction of vertically deficient edentulous ridges, (b) the regenerated bone withstood the functional demands of implant loading, (c) survival and success rates of implants placed in the distracted areas were consistent with those of implants placed in native bone, and (d) there is sufficient bone volume and maturity in the distracted region for primary stability of the implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This literature review was performed to analyse the outcomes of clinical studies of alveolar distraction osteogenesis (DO) listed by PUBMED between January 1996 and December 2006. A PUBMED search identified 128 articles on alveolar DO. Twenty articles covering 209 cases were analysed, considering location, device and procedural parameters, rate of augmentation, aspect of final implant placement and follow up. The mean latency period was 7.26+/-2.31 days, distraction rate 0.71+/-0.27 mm/day, rate of augmentation 6.88+/-2.52 mm and consolidation period 12.22+/-5.58 weeks. A total of 469 implants were placed and followed post loading for an average of 14.19+/-11.03 months, with a survival rate of 97%. Of the different procedural parameters, only the difference between mean consolidation period for failed (8.10+/-2.51 weeks) and successful (12.43+/-5.62 weeks) implants was statistically significant (P=0.01). Use of DO may be advantageous in terms of the success rate of implants placed in augmented sites, but there is still a lack of sufficient data based on long-term follow up. Future experimental studies should evaluate the application of different methods with a view to shortening the overall treatment period and improving the performance of implants placed in distracted alveolar ridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite its growing popularity, alveolar distraction osteogenesis (DO) is a technically challenging operation. The purpose of this review is to estimate the types and frequencies of complications in alveolar DO and to identify factors associated with them. 26 reports of alveolar DO found in the PubMed database that met the criteria for inclusion were studied. 256 patients underwent 270 DO procedures; 109 complications arose in 77 patients (30%) with 77 distractions (29%). In 27/77 patients, more than 1 complication occurred. 20 complications (7%) were a consequence of surgery, 32 (12%) occurred during distraction, 22 (8%) during the consolidation period and 35 (13%) post-distraction. The most common complications were insufficient bone formation following the consolidation period (22 cases, 8%), regression of distraction distance (18 cases, 7%) and problems related to the distractor device (16 cases, 6%). The most severe complications occurred in 4 cases (2%). The type of device used and an augmentation rate of more than 0.5 mm/24 h were significantly related to insufficient bone formation and evidence of complications. This review indicates that complications in alveolar DO are frequent, but rarely cause severe problems or clinical decline. Appropriate treatment selection, surgical technique and adjusted protocol should decrease the number of complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: In alveolar distraction, in cases of severe atrophy in particular, it is often difficult to perform osteotomies in order to make a transport segment in optimal size and shape. Moreover care must be taken, not to damage the closely locating anato- mical structures such as the maxillary sinus, the inferior alveolar nerve, and the roots of the neighboring teeth. For setting ideal osteotomy lines exactly, we have developed a CT-based preoperative planning tool. Methods: 3-dimensional visual reconstruction of the jaw is created from the preoperative CT scans (1.0-mm slice thick- ness). Using the image-processing software Mimics (Materialise, Yokohama, Japan), various procedures of virtual cutting are simulated first to determine optimal osteotomy lines and to design an ideal transport segment. After the computer planning, data from the virtual solid model are transferred to a rapid prototype model, and a guiding splint is made to transfer the planned surgical simulation to the actual surgery. Results: The method was used in a case of severe atrophy of the anterior maxilla. The patient had a large maxillary sinus requir- ing a precise osteotomy in this critical area. Using the splint allowing a 3-dimensional guidance, alveolar osteotomies were easily done to achieve a transport segment in sufficient dimen- sion as planned, and any perforation of the maxillary sinus could be avoided. Finally the alveolar distraction of 10mm has suc- cessfully been performed. Conclusion: The preoperative planning method and the guiding splint described here are useful in problematic cases requiring an extremely precise osteotomy due to lack of bony space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correction of complex deformities is a challenging procedure. Long-term wearing of a fixator after correction and lengthening are inconvenient and has a high rate of complication. The goals of the surgical treatment in the presented case were: (1) correction of the deformity and lengthening of the left leg by the Taylor spatial frame (TSF, Smith and Nephew, Marl, Germany); (2) reduction in the time the patient wears the TSF by changing the fixation system to a plate (lengthening then plating-LTP) and using a locking compression plate in conjunction with the 5.0 dynamic locking screws in order to accelerate bone healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The regenerative pathways during periosteal distraction osteogenesis may be influenced by the local environment composed by cells, growth factors, nutrition and mechanical load. The aim of the present study was to evaluate the influence of two protocols of periosteal distraction on bone formation. Custom made distraction devices were surgically fixed onto the calvariae of 60 rabbits. After an initial healing period of 7 days, two groups of animals were submitted to distraction rates of 0.25 and 0.5 mm/24 h for 10 days, respectively. Six animals per group were sacrificed 10 (mid-distraction), 17 (end-distraction), 24 (1-week consolidation), 31 (2-week consolidation) and 77 days (2-month consolidation) after surgery. Newly formed bone was assessed by means of micro-CT and histologically. Expression of transcripts encoding tissue-specific genes (BMP-2, RUNX2, ACP5, SPARC, collagen I α1, collagen II α1 and SOX9) was analyzed by quantitative PCR. Two patterns of bone formation were observed, originating from the old bone surface in Group I and from the periosteum in Group II. Bone volume (BV) and bone mineral density (BMD) significantly increased up to the 2-month consolidation period within the groups (p < 0.05). Significantly more bone was observed in Group II compared to Group I at the 2-month consolidation period (p < 0.001). Expression of transcripts encoding osteogenic genes in bone depended on the time-point of observation (p < 0.05). Low level of transcripts reveals an indirect role of periosteum in the osteogenic process. Two protocols of periosteal distraction in the present model resulted in moderate differences in terms of bone formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Published also as thesis (PH. D.) Columbia University.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of inhibitory control processes has been proposed as a mechanism constraining working-memory capacity. In order to investigate genetic influences on processes that may reflect interference control, event-related potential (ER-P) activity recorded at frontal sites, during distracting and nondistracting conditions of a working-memory task, in a sample of 509 twin pairs was examined. The ERP component of interest was the slow wave (SW). Considerable overlap in source of genetic influence was found, with a common genetic factor accounting for 37 - 45% of SW variance irrespective of condition. However, 3 - 8 % of SW variance in the distracting condition was influenced by an independent genetic source. These results suggest that neural responses to irrelevant and distracting information, that may disrupt working-memory performance, differ in a fundamental way from perceptual and memory-based processing in a working-memory task. Furthermore, the results are consistent with the view that cognition is a complex genetic trait influenced by numerous genes of small influence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Previous studies have reported errors in Activities of Daily Living (ADL) under the presence of distracting objects in dementia and brain injury patients. However, little is known about which distractor-target objects relation might be more harmful for performance. Method: We compared the ADL execution in frontal brain injured patients and control participants under two conditions: One in which target objects were mixed with distractor objects that constituted an alternative semantically related but non-required task (contextual condition) and another in which target objects were mixed with related but isolated distractors that did not constituted a coherent task (non-contextual condition). We separately analyzed ADL commission errors (repetitions, substitutions, objects manipulations, failures in sequence, extra actions) and omissions. In addition, the participants were evaluated with a neuropsychological protocol including a very specific executive functions task (Selective attention, Stimulus-Stimulus and Stimulus-Response conflict). Results: We found that frontal patients produced more commission errors compared to control participants, but only under the contextual condition. No between groups significant differences were found in omissions in both conditions or commission errors in non-contextual conditions. Scores in the Stimulus-Response conflict was significantly correlated with commission errors in the contextual condition. Conclusion: The presence of different non-target objects in ADL performance could require different cognitive process. Contextual ADL conditions required a higher level of executive functions, especially at the level of response (Stimulus-Response conflict). Application to Practice: Occupational therapists should control the presence of objects related to the target task according to the intervention objectives with the patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Speech recognition in car environments has been identified as a valuable means for reducing driver distraction when operating non-critical in-car systems. Likelihood-maximising (LIMA) frameworks optimise speech enhancement algorithms based on recognised state sequences rather than traditional signal-level criteria such as maximising signal-to-noise ratio. Previously presented LIMA frameworks require calibration utterances to generate optimised enhancement parameters which are used for all subsequent utterances. Sub-optimal recognition performance occurs in noise conditions which are significantly different from that present during the calibration session - a serious problem in rapidly changing noise environments. We propose a dialog-based design which allows regular optimisation iterations in order to track the changing noise conditions. Experiments using Mel-filterbank spectral subtraction are performed to determine the optimisation requirements for vehicular environments and show that minimal optimisation assists real-time operation with improved speech recognition accuracy. It is also shown that the proposed design is able to provide improved recognition performance over frameworks incorporating a calibration session.