998 resultados para diagnostic error


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The topic of fault detection and diagnostics (FDD) is studied from the perspective of proactive testing. Unlike most research focus in the diagnosis area in which system outputs are analyzed for diagnosis purposes, in this paper the focus is on the other side of the problem: manipulating system inputs for better diagnosis reasoning. In other words, the question of how diagnostic mechanisms can direct system inputs for better diagnosis analysis is addressed here. It is shown how the problem can be formulated as decision making problem coupled with a Bayesian Network based diagnostic mechanism. The developed mechanism is applied to the problem of supervised testing in HVAC systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In fault detection and diagnostics, limitations coming from the sensor network architecture are one of the main challenges in evaluating a system’s health status. Usually the design of the sensor network architecture is not solely based on diagnostic purposes, other factors like controls, financial constraints, and practical limitations are also involved. As a result, it quite common to have one sensor (or one set of sensors) monitoring the behaviour of two or more components. This can significantly extend the complexity of diagnostic problems. In this paper a systematic approach is presented to deal with such complexities. It is shown how the problem can be formulated as a Bayesian network based diagnostic mechanism with latent variables. The developed approach is also applied to the problem of fault diagnosis in HVAC systems, an application area with considerable modeling and measurement constraints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study Krylov subspace methods for approximating the matrix-function vector product φ(tA)b where φ(z) = [exp(z) - 1]/z. This product arises in the numerical integration of large stiff systems of differential equations by the Exponential Euler Method, where A is the Jacobian matrix of the system. Recently, this method has found application in the simulation of transport phenomena in porous media within mathematical models of wood drying and groundwater flow. We develop an a posteriori upper bound on the Krylov subspace approximation error and provide a new interpretation of a previously published error estimate. This leads to an alternative Krylov approximation to φ(tA)b, the so-called Harmonic Ritz approximant, which we find does not exhibit oscillatory behaviour of the residual error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty-four elementary school teachers and 32 education students from Canada rated their reactions towards vignettes describing children who met attention-deficit/hyperactivity disorder (ADHD) symptom criteria that included or did not include the label “ADHD.” “ADHD”-labeled vignettes elicited greater perceptions of the child's impairment as well as more negative emotions and less confidence in the participants, although it also increased participants' willingness to implement treatment interventions. Ratings were similar to vignettes of boys versus girls; however, important differences in ratings between teachers and education students emerged and are discussed. Finally, we investigated the degree to which teachers' professional backgrounds influenced bias based on the label “ADHD.” Training specific to ADHD consistently predicted label bias, whereas teachers' experience working with children with ADHD did not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement error model is a well established statistical method for regression problems in medical sciences, although rarely used in ecological studies. While the situations in which it is appropriate may be less common in ecology, there are instances in which there may be benefits in its use for prediction and estimation of parameters of interest. We have chosen to explore this topic using a conditional independence model in a Bayesian framework using a Gibbs sampler, as this gives a great deal of flexibility, allowing us to analyse a number of different models without losing generality. Using simulations and two examples, we show how the conditional independence model can be used in ecology, and when it is appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present a method for the recovery of position and absolute attitude (including pitch, roll and yaw) using a novel fusion of monocular Visual Odometry and GPS measurements in a similar manner to a classic loosely-coupled GPS/INS error state navigation filter. The proposed filter does not require additional restrictions or assumptions such as platform-specific dynamics, map-matching, feature-tracking, visual loop-closing, gravity vector or additional sensors such as an IMU or magnetic compass. An observability analysis of the proposed filter is performed, showing that the scale factor, position and attitude errors are fully observable under acceleration that is non-parallel to velocity vector in the navigation frame. The observability properties of the proposed filter are demonstrated using numerical simulations. We conclude the article with an implementation of the proposed filter using real flight data collected from a Cessna 172 equipped with a downwards-looking camera and GPS, showing the feasibility of the algorithm in real-world conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To critically examine the DSM-IV-TR criteria for Substance-Induced Psychotic Disorder (SIPD). Data sources: Leading electronic databases (such as Medline, Pubmed) were searched for the years 1992 through 2007, using combinations of the following key search terms: substance abuse/dependence, alcohol, marijuana, cannabis, methamphetamine, crack, cocaine, amphetamine, ecstasy, ketamine, phencyclidine, LSD, mental health, drug-induced psychosis, substance-induced psychosis, psychosis, schizophrenia. References identified from bibliographies of pertinent articles and books in the field were also collected and reviewed. Data extraction: Only research studies or case reports series that presented data on populations diagnosed with SIPD using clinical or structured diagnostic interviews published in English were used to assess the validity of the current SIPD criteria. Data synthesis: We identified 49 articles that presented clinical data on SIPD. The majority of these publications were case reports, with only 18 articles specifically focusing on delineating the clinical characteristics or outcomes of individuals diagnosed with SIPD. While several large studies have recently been conducted to assess the stability of SIPD, there is a dearth of research rigorously examining the validity of DSM-IV diagnostic criteria across substances. Conclusions: There remains a striking paucity of information on the outcome, treatment and best practice for substance-associated psychotic episodes. Further work is clearly required before the advent of DSM-V. We propose an alternative, broader classification that better reflects the current evidence base, inferring association rather than causation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few studies have specifically investigated the functional effects of uncorrected astigmatism on measures of reading fluency. This information is important to provide evidence for the development of clinical guidelines for the correction of astigmatism. Methods: Participants included 30 visually normal, young adults (mean age 21.7 ± 3.4 years). Distance and near visual acuity and reading fluency were assessed with optimal spectacle correction (baseline) and for two levels of astigmatism, 1.00DC and 2.00DC, at two axes (90° and 180°) to induce both against-the-rule (ATR) and with-the-rule (WTR) astigmatism. Reading and eye movement fluency were assessed using standardized clinical measures including the test of Discrete Reading Rate (DRR), the Developmental Eye Movement (DEM) test and by recording eye movement patterns with the Visagraph (III) during reading for comprehension. Results: Both distance and near acuity were significantly decreased compared to baseline for all of the astigmatic lens conditions (p < 0.001). Reading speed with the DRR for N16 print size was significantly reduced for the 2.00DC ATR condition (a reduction of 10%), while for smaller text sizes reading speed was reduced by up to 24% for the 1.00DC ATR and 2.00DC condition in both axis directions (p<0.05). For the DEM, sub-test completion speeds were significantly impaired, with the 2.00DC condition affecting both vertical and horizontal times and the 1.00DC ATR condition affecting only horizontal times (p<0.05). Visagraph reading eye movements were not significantly affected by the induced astigmatism. Conclusions: Induced astigmatism impaired performance on selected tests of reading fluency, with ATR astigmatism having significantly greater effects on performance than did WTR, even for relatively small amounts of astigmatic blur of 1.00DC. These findings have implications for the minimal prescribing criteria for astigmatic refractive errors.