992 resultados para coefficient of shrinkage


Relevância:

100.00% 100.00%

Publicador:

Resumo:

IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) – not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To quantify the frictional behaviour in sheet forming operations, several laboratory experiments which simulate the real forming conditions are performed. The Bending Under Tension Test is one such experiment which is often used to represent the frictional flow of sheet material around a die or a punch radius. Different mathematical representations are used to determine the coefficient of friction in the Bending Under Tension Test. In general the change in the strip thickness in passing over the die radius is neglected and the radius of curvature to thickness ratio is assumed to be constant in these equations. However, the effect of roller radius, sheet thickness and the surface pressure are also omitted in some of these equations. This work quantitatively determined the effect of roller radius and the tooling pressure on the coefficient of friction. The Bending Under Tension Test was performed using rollers with different radii and also lubricants with different properties. The tool radii were found to have a direct influence in the contact pressure. The effect of roller radius on friction was considerable and it was observed that there is a clear relationship between the contact pressure and the coefficient of friction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presentwork aimed to determine howthe average fibre diameter coefficient of variation (CVD) and fibre curvature (FC) differences between nine sampling sites vary between sex and flock, to identify differences in variability between sampling sites as a result of between animal and between sire variability and to determine correlations between sampling sites in between animal and between sire variability. Australian Angoras (n = 313) from two farms in southern Australia were sampled at 12 and 18 months of age at nine sites (mid side, belly, brisket, hind flank, hip, hock, mid back, neck, shoulder). Staples were taken prior to shearing at skin level and CVD and FC determined. For each shearing, differences in CVD and FC between sampling sites, how these differences were affected by farm, sex, and sire, and the covariance between sites for sire and individual animal effects were investigated by restricted maximum likelihood (REML) analyses. The median mid side CVD at 12 and 18 months of age ranged from 23.6 to 25.1% but the actual range was 16.8–34.2%. The median mid side FC at 12 and 18 months of age ranged from 14.4 to 18.6◦/mm but the actual range was 10.5–26.3◦/mm. The general pattern for CVDwas for the mid back, hip and neck sites to have similar CVD, the brisket, hind flank and hock sites to have larger CVD and the belly to have smaller CVD than the mid side site. The between animal variation for CVD was lowest at the mid back site. This implies that the mid back would be the most effective site for between animal selection for CVD. Heritabilities for CVD (range at 18 months 0.18–0.30) were only about half the heritabilities for mean fibre diameter in the same study. There was a marked anterior–posterior increase in FC at both farms and with both ages. The results give no clear indication of the best site for between animal selection for FC, other than that the hock should be avoided. Heritabilities for FC are moderate to high (range at 18 months 0.44–0.77) and the genetic correlations are high except for the hock. Thus genetic selection for FC at any site, other than the hock, should be effective for changing FC over the entire fleece. There was more variability between animals than between sites and sires. These results are put into context with associated research on variation in mean fibre diameter and staple length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances in thermoelectrochemical cells, which are being developed for harvesting low grade waste heat, have shown the promise of cobalt bipyridyl salts as the active redox couple. The Seebeck coefficient, Se, of a redox couple determines the open circuit voltage achievable, for a given temperature gradient, across the thermoelectrochemical cell. Thus, the accurate determination of this thermodynamic parameter is key to the development and study of new redox electrolytes. Further, techniques for accurate determination of Se using only one half of the redox couple reduces the synthetic requirements. Here, we compare three different experimental techniques for measuring Se of a cobalt tris(bipyridyl) redox couple in ionic liquid electrolytes. The use of temperature dependent cyclic voltammetry (CV) in isothermal and non-isothermal cells was investigated in depth, and the Se values compared to those from thermo-electromotive force measurements. Within experimental error, the Se values derived from CV methods were found to be in accordance with those obtained from electromotive force (emf) measurements. The applicability of cyclic voltammetry techniques for determining Se when employing only one part of the redox couple was demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The top faces of float glass samples were exposed to vapors resulting from the decomposition of KNO3 at 565 degrees C for up to 32 h. X-ray dispersive spectra (EDS) show that K+ ions migrate into the glass. The K+ concentration profile was obtained and its diffusion coefficient was calculated by the Boltzmann-Matano technique. The mean diffusion coefficient was approximately 10 X 10(-11) cm(2) s(-1). It was observed that the refractive index and the Vickers hardness decrease with the depth (after the removal of successive layers), and their profiles were thus obtained. These profiles enabled the calculation of the diffusion coefficient of K+ through the Boltzmann-Matano technique, with mean results ranging between 6 x 10(-11) and 30 x 10(-11) cm(2) s(-1). (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of the association between two random variables that have a joint normal distribution is of interest in applied statistics; for example, in statistical genetics. This article, targeted to applied statisticians, addresses inferences about the coefficient of correlation (ρ) in the bivariate normal and standard bivariate normal distributions using likelihood, frequentist, and Baycsian perspectives. Some results are surprising. For instance, the maximum likelihood estimator and the posterior distribution of ρ in the standard bivariate normal distribution do not follow directly from results for a general bivariate normal distribution. An example employing bootstrap and rejection sampling procedures is used to illustrate some of the peculiarities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three types of raw materials including commercial waste from saltwater (SW), freshwater fish (FW) and tilapia fillet residue (FR) were used to produce fish silage by either acid digestion (2% formic acid and 2% sulfuric acid) or anaerobic fermentation (5% of Lactobacillus plantarum and 15% sugar cane molasses). Six test diets were used in digestibility trials prepared with 70% reference diet and 30% of each experimental silage. These diets were fed to juvenile pacu Piaractus mesopotamicus (146 g average weight) in triplicate. Fish were kept in 500-L tanks and feces collected by manual extrusion. It was observed for both processes that SW waste always had the highest moisture content and lowest fat and ash. Highest crude protein levels were found in silages from commercial fish waste (SW and FW) made from whole fish unfit for human consumption. However, apparent digestibility coefficients did not vary among diets (P > 0.05). Although values did not differ statistically, fermented silage consistently displayed higher digestibility coefficients compared to acid silage. The silages exhibited relatively high protein digestibility (72.5-80.0%), thus suggesting the feasibility of using fish industry by-products in aquaculture feeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This papers presents results on the variation of the PMD coefficient of optical links under influence of mechanical tests, such as tensile strength, bending and compression, and also during the application of a thermal cycle. Results revealed that the link coefficient is more influenced by the application of a tension load and also suffers significant variation under strong temperature changes. Copyrigth © SBMO.