978 resultados para capillary electrophoresis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast and sensitive approach to detect reserpine in urine using micellar electrokinetic capillary chromatography with electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) detection is described. Using a 25 mum i.d. capillary as separation column, the ECL detector was coupled to the capillary in the absence of an electric field decoupler. Field-amplified injection was used to minimize the effect of ionic strength in the sample and to achieve high sensitivity. In this way, the sample was analyzed directly without any pretreatment. The method was validated for reserpine in the urine over the range of 1 x 10(-6) - 1 x 10(-4) mol/L with a correlation coefficient of 0.996. The RSD for reserpine at a level of 5 mumol/L was 4.3%. The LOD (S/N = 3) was estimated to be 7.0 x 10(-8) mol/L. The average recoveries for 10 mumol/L reserpine spiked in human urine were 94%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method for prolidase (PLD, EC 3.4.13.9) activity assay was developed based on the determination of proline produced from enzymatic reaction through capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(11) [Ru(bpy)(3)(2+)] electrochemiluminescence detection (ECL). A detection limit of 12.2 fmol (S/N = 3) for proline, corresponding to 1.22 x 10(-8) units of prolidase catalyzing for 1 min was achieved. PLD activity determined by CE-ECL method was in agreement with that obtained from the classical Chinard's one. CE-ECL showed its powerful resolving ability and selectivity as no sample pretreatmentwas needed and no interference existed. The clinical utility of this method was successfully demonstrated by its application to assay PLD activity in the serum of diabetic patients in order to evaluate collagen degradation in diabetes mellitus (DM). The results indicated that enhanced collagen degradation occurred in DM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We explored the CE with Ru(bpy)(3)(2+) electrochemiluminescence detection for the kinetic study of drug-enzyme interaction. Effects of four nonsteroidal anti - inflammatory drugs including aspirin, paracetamol, sodium salicylate and phenacetin on prolidase (PLD) activity in erythrocytes were investigated. Aspirin enhanced PLD activity whereas the other three had inhibiting effects. This may reveal their different effects on the collagen biosynthesis and catabolism that influence tumor invasiveness. Kinetic study of paracetamol on PLD showed that the value of Michaelis constant Km for PLD was 1.23 mM. The mechanism of PLD inhibition by paracetamol is noncompetitive inhibition, and the inhibitor constant K-i value obtained in our research was 9.73 x 10(3) mu g/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new sensitive assay for aspartate aminotransterase (AST) and alanine aminotransferase (ALT) activities in biofluids was developed, based on the separation and detection of alanine, glutamate, and aspartate using capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. The three amino acids were separated in 5 mM phosphate of pH 2.1 as background electrolyte, and detected on a 500 mu m platinum disk electrode at 1.2 V (versus Ag/AgCl) in the presence of 10 mM tris(2,2'-bipyridyl)ruthenium(II) dissolved in 80 mM phosphate of pH 10.5. A mass detection limit of 37.3 fmol (or 81.5 fmol) for glutamate, corresponding to the product in the enzyme reaction catalyzed by 1.24 x 10(-9) U AST (or 2.72 x 10(-9) U ALT) in a 30 min reaction period, was achieved. This assay was applied to investigate the cytotoxicity effect of ethanol on HepG2 cells and differentiating nonalcoholic steatohepatitis (NASH) from alcoholic liver disease, indicating that the technique is promising for the application in the cell biological and clinical fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with Ru(bpy)(3)(2+) electrochemiluminescence. (ECL) detection system was established to the determination of contamination of banknotes with controlled drugs and a high efficiency on-column field-amplified sample stacking (FASS) technique was also optimized to increase the ECL intensity. The method was illustrated using heroin and cocaine, which are two typical and popular illicit drugs. Highest sample stacking was obtained when 0.01 mM acetic acid was chosen for sample dissolution with electrokinetical injection for 6 s at 17 kV. Under the optimized conditions: ECL detection at 1.2 V, separation voltage 10.0 kV, 20 mM phosphate-acetate (pH 7.2) as running buffer, 5 mM Ru(bpy)(3)(2+) with 50 mM phosphate-acetate (pH 7.2) in the detection cell, the standard curves were linear in the range of 7.50 x 10(-8) to 1.00 x 10(-5) M for heroin and 2.50 x 10(-7) to 1.00 x 10(-4) M for cocaine and detection limits of 50 nM for heroin and 60 nM for cocaine were achieved (S/N = 3), respectively. Relative standard derivations of the ECL intensity and the migration time were 3.50 and 0.51% for heroin and 4.44 and 0.12% for cocaine, respectively.The developed method was successfully applied to the determination of heroin and cocaine on illicit drug contaminated banknotes without any damage of the paper currency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aristolochic acids (AAs) are the main bioactive ingredients in the most of Aristolochia plants, which are used to make dietary supplements, slimming pills and Traditional Chinese Medicines (TCMs). Excessive ingestion of AAs can lead to serious nephropathy. Therefore, quantitative analysis and quality control for the plants containing AAs is of great importance. In this paper, capillary electrophoresis (CE) with electrochemical detection (ED) at a 33 mu m carbon fiber microdisk electrode (CFE) has been applied to detect AA-I and AA-II in Aristolochia plants. Under the optimum conditions: detection potential at 1.20 V, 2.0 x 10(-2) mol L-1 phosphate buffer solution (PBS) (pH 10.0), injection time 25 s at a height of 17 cm and separation voltage at 12.5 kV, the AA-I and AA-II were baseline separated within 5 min. Low detection limits for AA-I and AA-II were 4.0 x 10(-8) mol L-1 and 1.0 x 10(-7) mol L-1, respectively. Wide linear ranges were from 4.0 x 10(-8) mol L-1 to 1.9 x 10(-5) mol L-1 and 1.0 X 10(-7) mol L-1 to 5.0 x 10(-5) mol L-1 for AA-I and AA-II, respectively. The proposed method has been successfully applied to analyze AAs contents in plant extracts. The results indicated that the contents of AAs in each part of Aristolochia debilis Sieb. Et Zucc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10 s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N = 3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with amperometric detection (AD) has been widely used in various fields of analytical science, especially in the pharmaceutical industry recently due to its high separation efficiency and low detection limit. The determination of active ingredients in Chinese herb medicines by CE-AD is of great importance in developing the researches on pharmacology of herbs, quantitative analysis and quality control. Analyses of the effective components in Chinese herb medicines and compound Chinese herb medicine by CE-AD are reviewed in this paper. In contrast with other analysis methods, the advantage of CE-AD is discussed. The development in analyses of traditional Chinese medicine (TCM) by CE-AD in future is mentioned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tramadol and lidocaine, used as analgesic and local anesthetic in surgery, are partly excreted by kidney. For the first time, we developed a simple and sensitive method, based on capillary electrophoresis with electrochemiluminescence (ECL) detection by end column mode without joint to monitor tramadol and lidocaine in urine. To eliminate the influence of ionic strength of urine sample, analytes were extracted by ether. Tripropylamine (TPA) was used as internal standard. ne recoveries of tramadol and lidocaine were between 94% and 97% at different levels. The method exhibited the linear range for the tramadol and lidocaine from 1.0 X 10(-7) to 1.0 X 10(-4) mol/L with correlation efficient of 0.998. The relative standard deviation (RSD) was 2.9% and 2.7% (n = 8) for tramadol and lidocaine, respectively. The limit of detection (LOD) was 6.0 x 10(-8) mol/L and 4.5 x 10(-8), mol/L (S/N = 3) for tramadol and lidocaine, respectively. The application for detecting tramadol and lidocaine in urine of patients showed that the method was valuable in clinical and biochemical laboratories for detecting tramadol, lidocaine and other tertiary amine pharmaceuticals for various purpose, such as metabolism investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bPY)(3)(2divided by) ECL detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an indium tin oxide (ITO) electrode-based Ru(bPY)(3)(2+) electrochemiluminecence (ECL) detector for a microchip capillary electrophoresis (CE). The microchip CE-ECL system described in this article consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate with an ITO electrode fabricated by a photolithographic method. The PDMS layer was reversibly bound to the ITO electrode plate, which greatly simplified the alignment of the separation channel with the working electrode and enhanced the photon-capturing efficiency. In our study, the high separation electric field had no significant influence on the ECL detector, and decouplers for isolating the separation electric field were not needed in the microchip CE-ECL system. The ITO electrodes employed in the experiments displayed good durability and stability in the analytical procedures. Proline was selected to perform the microchip device with a limit of detection of 1.2 muM (S/N = 3) and a linear range from 5 to 600 muM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Discrete wavelets transform (DWT). was applied to noise on removal capillary electrophoresis-electrochemiluminescence (CE-ECL) electropherograms. Several typical wavelet transforms, including Haar, Daublets, Coiflets, and Symmlets, were evaluated. Four types of determining threshold methods, fixed form threshold, rigorous Stein's unbiased estimate of risk (rigorous SURE), heuristic SURE and minimax, combined with hard and soft thresholding methods were compared. The denoising study on synthetic signals showed that wave Symmlet 4 with a level decomposition of 5 and the thresholding method of heuristic SURE-hard provide the optimum denoising strategy. Using this strategy, the noise on CE-ECL electropherograms could be removed adequately. Compared with the Savitzky-Golay and Fourier transform denoising methods, DWT is an efficient method for noise removal with a better preservation of the shape of peaks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)(3)(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cm x 25 mum (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1 mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 muA), with end-column Ru(bpy)(3)(2+) ECL detection. A 5 mmol/L Ru(bpy)(3)(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9 x 10(-7) mol/L and 7.6 x 10(-9) mol/L for Spd and Spm, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report the construction and application of a sol-gel derived carbon composite electrode (CCE) as an amperometric detector for capillary electrophoresis. The electrochemical properties were characterized and compared with those of conventional carbon fiber and carbon paste electrode (CPE). Experimental results show that peak-to-peak noise of CCE was about 20% of CPE and electrode capacitance was comparatively low. When applied to the detection of dopamine and epinephrine, the optimal detection potential for CCE was 0.1 V lower than CPE under the same separation conditions; CCE with diameter of 75 and 100 mum could achieve a low detection limit of 3.10(-8) and 6.10(-8) M for the detection of epinephrine, which approaching that of the 33-mum diameter carbon fiber electrode. Also, the linearity for epinephrine at CCE was more than two orders of magnitude, which was slightly wider than that of carbon fiber electrode. Applications to real sample analysis were tested by the determination of betahistine dihydrochloride in tablets and human urine. Using CCE with diameter less than or equal to100 mum as an amperometric detector after capillary electrophoresis separation, a low detection limit and a wide linear range combined with excellent reproducibility were obtained. This CCE possesses of many advantages, namely, convenience, ease of fabrication, low cost and high stability.