949 resultados para LC-MS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A common problem encountered during the development of MS methods for the quantitation of small organic molecules by LGMS is the formation of non-covalently bound species or adducts in the electrospray interface. Often the population of the molecular ion is insignificant compared to those of all other forms of the analyte produced in the electrospray, making it difficult to obtain the sensitivity required for accurate quantitation. We have investigated the effects of the following variables: orifice potential, nebulizer gas flow, temperature, solvent composition and the sample pH on the relative distributions of ions of the types MH+, MNa+, MNH+, and 2MNa(+), where M represents a 4 small organic molecule: BAY 11-7082 ((E)-3-[4-methylphenylsulfonyl]-2-propenenitrile). Orifice potential, solvent composition and the sample pH had the greatest influence on the relative distributions of these ions, making these parameters the most useful for optimizing methods for the quantitation of small molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phospholipids are complex and varied biomolecules that are susceptible to lipid peroxidation after attack by free radicals or electrophilic oxidants and can yield a large number of different oxidation products. There are many available methods for detecting phospholipid oxidation products, but also various limitations and problems. Electrospray ionization mass spectrometry allows the simultaneous but specific analysis of multiple species with good sensitivity and has a further advantage that it can be coupled to liquid chromatography for separation of oxidation products. Here, we explain the principles of oxidized phospholipid analysis by electrospray mass spectrometry and describe fragmentation routines for surveying the structural properties of the analytes, in particular precursor ion and neutral loss scanning. These allow targeted detection of phospholipid headgroups and identification of phospholipids containing hydroperoxides and chlorine, as well as the detection of some individual oxidation products by their specific fragmentation patterns. We describe instrument protocols for carrying out these survey routines on a QTrap5500 mass spectrometer and also for interfacing with reverse-phase liquid chromatography. The article highlights critical aspects of the analysis as well as some limitations of the methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phagocytic cells produce a variety of oxidants as part of the immune defence, which react readily both with proteins and lipids, and could contribute to the oxidation of low density lipoprotein in atherosclerosis. We have investigated the oxidation of phospholipid vesicles by isolated human polymorphonuclear and mononuclear leukocytes, to provide a model of lipid oxidation in the absence of competing protein. PMA-stimulated cells were incubated with phospholipid vesicles contammg dipalmitoyl phosphatidylcholine (DPPC), palmitoyl-arachidonoyl phosphatidylcholine (PAPC), and stearoyl-oleoyl phosphatidylcholine (SOPC), before extraction of the lipids for analysis by HPLC coupled to electrospray mass spectrometry. In this system, oxidized phosphatidylcholines elute earlier than the native lipids owing to their decreased hydrophobicity, and can be identified according to their molecular mass. The formation of monohydroperoxides of P APC was observed routinely, together with low levels of hydroxides, but no chlorohydrin derivatives of P APC or SOPC were detected. However, the major oxidized product occurred at 828 m/z, and was identified as I-palmitoyl-2-(5,6-epoxyisoprostane E2)-sn-glycero-3-phosphocholine. These results show that phagocytes triggered by PMA cause oxidative damage to lipids predominantly by free radical mechanisms, and that electrophilic addition involving HOCl is not a major mechanism of attack. The contribution of myeloperoxidase and metal ions to the oxidation process is currently being investigated, and preliminary data suggest that myeloperoxidase-derived oxidants are responsible for the epoxyisoprostane phospholipid formation. The identification of an epoxyisoprostane phospholipid as the major product following phagocyte-induced phospholipid oxidation is novel and has implications for phagocyte involvement in atherogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Sucralose has gained popularity as a low calorie artificial sweetener worldwide. Due to its high stability and persistence, sucralose has shown widespread occurrence in environmental waters, at concentrations that could reach up to several μg/L. Previous studies have used time consuming sample preparation methods (offline solid phase extraction/derivatization) or methods with rather high detection limits (direct injection) for sucralose analysis. This study described a faster and sensitive analytical method for the determination of sucralose in environmental samples. Results An online SPE-LC–MS/MS method was developed, being capable to quantify sucralose in 12 minutes using only 10 mL of sample, with method detection limits (MDLs) of 4.5 ng/L, 8.5 ng/L and 45 ng/L for deionized water, drinking and reclaimed waters (1:10 diluted with deionized water), respectively. Sucralose was detected in 82% of the reclaimed water samples at concentrations reaching up to 18 μg/L. The monthly average for a period of one year was 9.1 ± 2.9 μg/L. The calculated mass loads per capita of sucralose discharged through WWTP effluents based on the concentrations detected in wastewaters in the U. S. is 5.0 mg/day/person. As expected, the concentrations observed in drinking water were much lower but still relevant reaching as high as 465 ng/L. In order to evaluate the stability of sucralose, photodegradation experiments were performed in natural waters. Significant photodegradation of sucralose was observed only in freshwater at 254 nm. Minimal degradation (<20%) was observed for all matrices under more natural conditions (350 nm or solar simulator). The only photolysis product of sucralose identified by high resolution mass spectrometry was a de-chlorinated molecule at m/z 362.0535, with molecular formula C12H20Cl2O8. Conclusions Online SPE LC-APCI/MS/MS developed in the study was applied to more than 100 environmental samples. Sucralose was frequently detected (>80%) indicating that the conventional treatment process employed in the sewage treatment plants is not efficient for its removal. Detection of sucralose in drinking waters suggests potential contamination of surface and ground waters sources with anthropogenic wastewater streams. Its high resistance to photodegradation, minimal sorption and high solubility indicate that sucralose could be a good tracer of anthropogenic wastewater intrusion into the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans les dernières années, les perturbateurs endocriniens ont été observés dans les rivières qui reçoivent des entrées importantes d’eaux usées. Parmi les perturbateurs endocriniens, les hormones stéroïdiennes naturelles et synthétiques sont des composés dont le potentiel d'imiter ou d'interférer avec les fonctions hormonales normales (développement, croissance et reproduction), est reconnu même au niveau ultra-traces (ng L-1). Bien que les hormones conjuguées soient moins actives que les hormones libres, elles peuvent être clivées et redevenir libres une fois exposées aux processus microbiens avant ou pendant le traitement des eaux usées. En raison de la nécessité d'identifier et de quantifier ces composés dans l'eau, une nouvelle méthode, entièrement automatisée, a été développée pour la détermination simultanée des deux formes de plusieurs hormones stéroïdiennes (conjuguées et libres) dans les matrices d'eau et dans l’urine des femmes. La méthode est basée sur l'extraction en phase solide couplée en ligne à la chromatographie liquide et la spectrométrie de masse en tandem (SPE-LC-MS/MS). Plusieurs paramètres ont été évalués dans le but d'optimiser l'efficacité de la méthode, tels que le type et le débit de la phase mobile, des différentes colonnes de SPE et de chromatographie, ainsi que différentes sources et modes d'ionisation des échantillons pour la MS. La méthode démontre une bonne linéarité (R2 > 0.993), ainsi qu'une précision avec un coefficient de variance inférieure à 10%. Les limites de quantification varient d’un minimum de 3 à 15 ng L-1 pour un volume d'injection entre 1 mL et 5 mL et le recouvrement des composés varie de 72 % à 117 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residents of certain areas of Tanzania are exposed to mycotoxins through the consumption of contaminated maize based foods. In this study, 101 maize based porridge samples were collected from villages of Nyabula, Kikelelwa and Kigwa located in different agro-ecological zones of Tanzania. The samples were collected at three time points (time point 1, during maize harvest; time point 2, 6 months after harvest; time point 3, 12 months after harvest) over a 1-year period. Ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was used to detect and quantify 9 mycotoxins: aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2), fumonisin B1 (FB1), fumonisin B2 (FB2), deoxynivalenol (DON), ochratoxin A (OTA) and zearaleneone (ZEN) in the samples following a QuEChERS extraction method. Eighty two percent of samples were co-contaminated with more than one group of mycotoxins. Fumonisins (FB1 + FB2) had the highest percentage occurrence in all 101 samples (100%) whereas OTA had the lowest (5%). For all three villages the mean concentration of FB1 was lowest in samples taken from time point 2. Conversely, In Kigwa village there was a distinct trend that AFB1 mean concentration was highest in samples taken from time point 2. DON concentration did not differ greatly between time points but the percentage occurrence varied between villages, most notably in Kigwa where 0% of samples tested positive. ZEN occurrence and mean concentration was highest in Kikelelwa. The results suggest that mycotoxin contamination in maize can vary based on season and agro-ecological zones. The high occurrence of multiple mycotoxins found in maize porridge, a common weaning food in Tanzania, presents a potential increase in the risk of exposure and significant health implications in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: It is well established that ionizing radiation induces a variety of damage in DNA by direct effects that are mediated by one-electron oxidation and indirect effects that are mediated by the reaction of water radiolysis products, e.g., hydroxyl radicals (•OH). In cellular DNA, direct and indirect effects appear to have about an equal effect toward DNA damage. We have shown that ϒ-(gamma) ray irradiation of aqueous solutions of DNA, during which •OH is the major damaging ROS can lead to the formation several lesions. On the other hand, the methylation and oxidative demethylation of cytosine in CpG dinucleotides plays a critical role in the gene regulation. The C5 position of cytosine in CG dinucleotides is frequently methylated by DNA methyl transferees (DNMTs) and constitutes 4-5% of the total cytosine. Here, my PhD research work focuses on the analysis of oxidative base modifications of model compounds of methylated and non methylated oligonucleotides, isolated DNA (calf-thymus DNA) and F98 cultured cell by gamma radiation. In addition, we identified a series of modifications of the 2-deoxyribose moiety of DNA arising from the exposure of isolated and cellular DNA to ionizing radiation. We also studied one electron oxidation of cellular DNA in cultured human HeLa cells initiated by intense nanosecond 266 nm laser pulse irradiation, which produces cross-links between guanine and thymine bases (G*-T*). To achieve these goals, we developed several methods based on mass spectrometry to analyze base modifications in isolated DNA and cellular DNA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans les dernières années, les perturbateurs endocriniens ont été observés dans les rivières qui reçoivent des entrées importantes d’eaux usées. Parmi les perturbateurs endocriniens, les hormones stéroïdiennes naturelles et synthétiques sont des composés dont le potentiel d'imiter ou d'interférer avec les fonctions hormonales normales (développement, croissance et reproduction), est reconnu même au niveau ultra-traces (ng L-1). Bien que les hormones conjuguées soient moins actives que les hormones libres, elles peuvent être clivées et redevenir libres une fois exposées aux processus microbiens avant ou pendant le traitement des eaux usées. En raison de la nécessité d'identifier et de quantifier ces composés dans l'eau, une nouvelle méthode, entièrement automatisée, a été développée pour la détermination simultanée des deux formes de plusieurs hormones stéroïdiennes (conjuguées et libres) dans les matrices d'eau et dans l’urine des femmes. La méthode est basée sur l'extraction en phase solide couplée en ligne à la chromatographie liquide et la spectrométrie de masse en tandem (SPE-LC-MS/MS). Plusieurs paramètres ont été évalués dans le but d'optimiser l'efficacité de la méthode, tels que le type et le débit de la phase mobile, des différentes colonnes de SPE et de chromatographie, ainsi que différentes sources et modes d'ionisation des échantillons pour la MS. La méthode démontre une bonne linéarité (R2 > 0.993), ainsi qu'une précision avec un coefficient de variance inférieure à 10%. Les limites de quantification varient d’un minimum de 3 à 15 ng L-1 pour un volume d'injection entre 1 mL et 5 mL et le recouvrement des composés varie de 72 % à 117 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O desenvolvimento de métodos adequados que permitam o monitoramento de resíduos e contaminantes em alimentos é de suma importância pois é a única forma de garantir a segurança dos alimentos evitando danos à saúde do consumidor. Para isso, fazse necessário que estes métodos sejam rápidos, fáceis e de baixo custo, capazes de detectar a presença de resíduos em concentrações baixas e em diferentes matrizes. Este trabalho consistiu no desenvolvimento de método para determinação de 5 sedativos e 14 β-bloqueadores em amostras de rim suíno e posterior análise por Cromatografia Líquida Acoplada à Espectrometria de Massas em Série (LC-MS/MS). O procedimento de extração que melhor se adequou para análise destes compostos consistiu na pesagem de 2 g de amostra e adição de 10 mL de acetonitrila seguida de homogeneização com auxílio de Ultra-Turrax e mesa agitadora. Após extração, as amostras foram submetidas a duas técnicas de clean-up, sendo elas, congelamento do extrato à baixa temperatura e extração em fase sólida dispersiva (d-SPE) utilizando como sorvente Celite® 545. Uma etapa de concentração foi realizada com auxílio de concentrador de amostras sob fluxo de N2 e temperatura controlada. As amostras secas foram retomadas com metanol e analisadas utilizando sistema LC-MS/MS com Ionização por Eletrospray (ESI), operando no modo MRM positivo, coluna Poroshell 120 EC-C18 (3,0 x 50 mm, 2,7 μm) para separação dos analitos, e gradiente de fase móvel composta por (A) solução aquosa acidificada com 0,1% de ácido fórmico (v/v) e (B) metanol 0,1% ácido fórmico (v/v). Os parâmetros de validação avaliados foram linearidade, seletividade, efeito matriz, precisão, veracidade, recuperação, limite de decisão, capacidade de detecção, incerteza da medição, robustez, limite de detecção e de quantificação. Além disso foram observados os critérios de desempenho aplicáveis à detecção por espectrometria de massas e estabilidade dos compostos. A recuperação foi avaliada em 10 μg kg-1 e a veracidade em 5, 10 e 15 μg kg-1 apresentando resultados satisfatórios entre 70 - 85% e 90 - 101%, respectivamente. O limite de quantificação determinado foi de 2,5 μg kg-1 , exceto para carazolol que foi de 1,25 μg kg- 1 . O estudo de linearidade foi realizado entre 0 e 20 μg kg-1 apresentando coeficientes de determinação superiores a 0,98. Estes procedimentos foram realizados através de análise de matriz branca fortificada. Além disso, o presente método foi utilizado para analisar carazolol, azaperone e azaperol em amostras de ensaio colaborativo de rim suíno, apresentando resultados muito próximos aos reais. Portanto, é possível concluir que o método desenvolvido é adequado para análise de sedativos e β-bloqueadores através de extração dos compostos e limpeza do extrato eficientes utilizando procedimentos rápidos, fáceis e de baixo custo, garantindo resultados seguros e confiáveis.