209 resultados para Handheld


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Driving on an approach to a signalized intersection while distracted is relatively risky, as potential vehicular conflicts and resulting angle collisions tend to be relatively more severe compared to other locations. Given the prevalence and importance of this particular scenario, the objective of this study was to examine the decisions and actions of distracted drivers during the onset of yellow lights. Driving simulator data were obtained from a sample of 69 drivers under baseline and handheld cell phone conditions at the University of Iowa – National Advanced Driving Simulator. Explanatory variables included age, gender, cell phone use, distance to stop-line, and speed. Although there is extensive research on drivers’ responses to yellow traffic signals, the examinations have been conducted from a traditional regression-based approach, which do not necessary provide the underlying relations and patterns among the sampled data. In this paper, we exploit the benefits of both classical statistical inference and data mining techniques to identify the a priori relationships among main effects, non-linearities, and interaction effects. Results suggest that the probability of yellow light running increases with the increase in driving speed at the onset of yellow. Both young (18–25 years) and middle-aged (30–45 years) drivers reveal reduced propensity for yellow light running whilst distracted across the entire speed range, exhibiting possible risk compensation during this critical driving situation. The propensity for yellow light running for both distracted male and female older (50–60 years) drivers is significantly higher. Driver experience captured by age interacts with distraction, resulting in their combined effect having slower physiological response and being distracted particularly risky.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Travel speed is one of the most critical parameters for road safety; the evidence suggests that increased vehicle speed is associated with higher crash risk and injury severity. Both naturalistic and simulator studies have reported that drivers distracted by a mobile phone select a lower driving speed. Speed decrements have been argued to be a risk compensatory behaviour of distracted drivers. Nonetheless, the extent and circumstances of the speed change among distracted drivers are still not known very well. As such, the primary objective of this study was to investigate patterns of speed variation in relation to contextual factors and distraction. Using the CARRS-Q high-fidelity Advanced Driving Simulator, the speed selection behaviour of 32 drivers aged 18-26 years was examined in two phone conditions: baseline (no phone conversation) and handheld phone operation. The simulator driving route contained five different types of road traffic complexities, including one road section with a horizontal S curve, one horizontal S curve with adjacent traffic, one straight segment of suburban road without traffic, one straight segment of suburban road with traffic interactions, and one road segment in a city environment. Speed deviations from the posted speed limit were analysed using Ward’s Hierarchical Clustering method to identify the effects of road traffic environment and cognitive distraction. The speed deviations along curved road sections formed two different clusters for the two phone conditions, implying that distracted drivers adopt a different strategy for selecting driving speed in a complex driving situation. In particular, distracted drivers selected a lower speed while driving along a horizontal curve. The speed deviation along the city road segment and other straight road segments grouped into a different cluster, and the deviations were not significantly different across phone conditions, suggesting a negligible effect of distraction on speed selection along these road sections. Future research should focus on developing a risk compensation model to explain the relationship between road traffic complexity and distraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leaf carbon (C) content, leaf nitrogen (N) content, and C:N ratio are especially useful for understanding plant-herbivore interactions and may be important in developing control methods for the invasive riparian plant Arundo donax L. We measured C content, N content, C:N ratio, and chlorophyll index (SPAD 502 reading) for 768 leaves from A. donax collected over a five year period at several locations in California, Nevada, and Texas. Leaf N was more variable than leaf C, and thus we developed a linear regression equation for estimating A. donax leaf N from the leaf chlorophyll index (SPAD reading). When applied to two independent data sets, the equation (leaf N content % = -0.63 + 0.08 x SPAD) produced realistic estimates that matched seasonal and spatial trends reported from a natural A. donax population. Used in conjunction with the handheld SPAD 502 meter, the equation provides a rapid, non-destructive method for estimating A. donax leaf quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isolating, purifying, and identifying proteins in complex biological matrices is often difficult, time consuming, and unreliable. Herein we describe a rapid screening technique for proteins in biological matrices that combines selective protein isolation with direct surface enhanced Raman spectroscopy (SERS) detection. Magnetic core gold nanoparticles were synthesised, characterised, and subsequently functionalized with recombinant human erythropoietin (rHuEPO)-specific antibody. The functionalized nanoparticles were used to capture rHuEPO from horse blood plasma within 15 minutes. The selective binding between the protein and the functionalized nanoparticles was monitored by SERS. The purified protein was then released from the nanoparticles’ surface and directly spectroscopically identified on a commercial nanopillar SERS substrate. ELISA independently confirmed the SERS identification and quantified the released rHuEPO. Finally, the direct SERS detection of the extracted protein was successfully demonstrated for in-field screening by a handheld Raman spectrometer within 1 minute sample measurement time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of head-mounted displays (HMDs) can produce both positive and negative experiences. In an effort increase positive experiences and avoid negative ones, researchers have identified a number of variables that may cause sickness and eyestrain, although the exact nature of the relationship to HMDs may vary, depending on the tasks and the environments. Other non-sickness-related aspects of HMDs, such as users opinions and future decisions associated with task enjoyment and interest, have attracted little attention in the research community. In this thesis, user experiences associated with the use of monocular and bi-ocular HMDs were studied. These include eyestrain and sickness caused by current HMDs, the advantages and disadvantages of adjustable HMDs, HMDs as accessories for small multimedia devices, and the impact of individual characteristics and evaluated experiences on reported outcomes and opinions. The results indicate that today s commercial HMDs do not induce serious sickness or eyestrain. Reported adverse symptoms have some influence on HMD-related opinions, but the nature of the impact depends on the tasks and the devices used. As an accessory to handheld devices and as a personal viewing device, HMDs may increase use duration and enable users to perform tasks not suitable for small screens. Well-designed and functional, adjustable HMDs, especially monocular HMDs, increase viewing comfort and usability, which in turn may have a positive effect on product-related satisfaction. The role of individual characteristics in understanding HMD-related experiences has not changed significantly. Explaining other HMD-related experiences, especially forward-looking interests, also requires understanding more stable individual traits and motivations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study examined the potential of Near Infrared Reflectance (NIR) spectroscopy for field diagnosis of hybrids between Corymbia (formerly Eucalyptus) species. NIR profiles were generated by scanning foliage from a total of 383 hybrid and 533 parental seedlings grown in a common garden and partial least squares discriminant analysis was used to test three-way model power to assign individuals to their appropriate taxon; either a parental or F1 hybrid class. Using the optimised conditions, fresh foliage from eight-month-old seedlings and a handheld NIR instrument (950–1800 nm), the mean assignment rates for the three hybrid groups ranged from 76% to 90%. Hybrid-parent contrast of NIR spectra deviated more so than parent–parent contrast. The F1 taxon assignment rates were usually higher than those for parents at 100% and 72%, respectively. Hybrid resolution was even greater for 2nd generation backcross hybrids. Similar to studies of morphology, taxon assignments tended to be more accurate for hybrid groups in which the parental taxa were more divergent. The practical application of this technique for hybrid diagnosis of seedlings in the nursery will require careful attention to control environmental factors because seedling age and storage effects influenced the ability of NIR to identify hybrids. The technique may also necessitate the generation of comparable reference populations, although exclusions approaches to analysis may circumvent the need for reference populations. The application of NIR in field diagnosis will be further complicated by the need to generate global models across environments but such models have been obtained for reliable prediction of chemistries in other situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While mobile phones have become ubiquitous in modern society, the use of mobile phones while driving is increasing at an alarming rate despite the associated crash risks. A significant safety concern is that driving while distracted by a mobile phone is more prevalent among young drivers, a less experienced driving cohort with elevated crash risk. The objective of this study was to examine the gap acceptance behavior of distracted young drivers at roundabouts. The CARRS-Q Advanced Driving Simulator was used to test participants on a simulated gap acceptance scenario at roundabouts. Conflicting traffic from the right approach of a four-legged roundabout were programmed to have a series of vehicles having the gaps between them proportionately increased from two to six seconds. Thirty-two licensed young drivers drove the simulator under three phone conditions: baseline (no phone conversation), hands-free and handheld phone conversations. Results show that distracted drivers started responding to the gap acceptance scenario at a distance closer to the roundabout and approached the roundabout at slower speeds. They also decelerated at faster rates to reduce their speeds prior to gap acceptance compared to non-distracted drivers. Although accepted gap sizes were not significantly different across phone conditions, differences in the safety margins at various gap sizes—measured by Post Encroachment Time (PET) between the driven vehicle and the conflicting vehicle—were statistically significant across phone conditions. PETs for distracted drivers were smaller across different gap sizes, suggesting a lower safety margin taken by distracted drivers compared to non-distracted drivers. The results aid in understanding how cognitive distraction resulting from mobile phone conversations while driving influences driving behavior during gap acceptance at roundabouts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To report the cost-effectiveness of a tailored handheld computerized procedural preparation and distraction intervention (Ditto) used during pediatric burn wound care in comparison to standard practice. METHODS An economic evaluation was performed alongside a randomized controlled trial of 75 children aged 4 to 13 years who presented with a burn to the Royal Children's Hospital, Brisbane, Australia. Participants were randomized to either the Ditto intervention (n = 35) or standard practice (n = 40) to measure the effect of the intervention on days taken for burns to re-epithelialize. Direct medical, direct nonmedical, and indirect cost data during burn re-epithelialization were extracted from the randomized controlled trial data and combined with scar management cost data obtained retrospectively from medical charts. Nonparametric bootstrapping was used to estimate statistical uncertainty in cost and effect differences and cost-effectiveness ratios. RESULTS On average, the Ditto intervention reduced the time to re-epithelialize by 3 days at AU$194 less cost for each patient compared with standard practice. The incremental cost-effectiveness plane showed that 78% of the simulated results were within the more effective and less costly quadrant and 22% were in the more effective and more costly quadrant, suggesting a 78% probability that the Ditto intervention dominates standard practice (i.e., cost-saving). At a willingness-to-pay threshold of AU$120, there is a 95% probability that the Ditto intervention is cost-effective (or cost-saving) against standard care. CONCLUSIONS This economic evaluation showed the Ditto intervention to be highly cost-effective against standard practice at a minimal cost for the significant benefits gained, supporting the implementation of the Ditto intervention during burn wound care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Emerging embedded applications are based on evolving standards (e.g., MPEG2/4, H.264/265, IEEE802.11a/b/g/n). Since most of these applications run on handheld devices, there is an increasing need for a single chip solution that can dynamically interoperate between different standards and their derivatives. In order to achieve high resource utilization and low power dissipation, we propose REDEFINE, a polymorphic ASIC in which specialized hardware units are replaced with basic hardware units that can create the same functionality by runtime re-composition. It is a ``future-proof'' custom hardware solution for multiple applications and their derivatives in a domain. In this article, we describe a compiler framework and supporting hardware comprising compute, storage, and communication resources. Applications described in high-level language (e.g., C) are compiled into application substructures. For each application substructure, a set of compute elements on the hardware are interconnected during runtime to form a pattern that closely matches the communication pattern of that particular application. The advantage is that the bounded CEs are neither processor cores nor logic elements as in FPGAs. Hence, REDEFINE offers the power and performance advantage of an ASIC and the hardware reconfigurability and programmability of that of an FPGA/instruction set processor. In addition, the hardware supports custom instruction pipelining. Existing instruction-set extensible processors determine a sequence of instructions that repeatedly occur within the application to create custom instructions at design time to speed up the execution of this sequence. We extend this scheme further, where a kernel is compiled into custom instructions that bear strong producer-consumer relationship (and not limited to frequently occurring sequences of instructions). Custom instructions, realized as hardware compositions effected at runtime, allow several instances of the same to be active in parallel. A key distinguishing factor in majority of the emerging embedded applications is stream processing. To reduce the overheads of data transfer between custom instructions, direct communication paths are employed among custom instructions. In this article, we present the overview of the hardware-aware compiler framework, which determines the NoC-aware schedule of transports of the data exchanged between the custom instructions on the interconnect. The results for the FFT kernel indicate a 25% reduction in the number of loads/stores, and throughput improves by log(n) for n-point FFT when compared to sequential implementation. Overall, REDEFINE offers flexibility and a runtime reconfigurability at the expense of 1.16x in power and 8x in area when compared to an ASIC. REDEFINE implementation consumes 0.1x the power of an FPGA implementation. In addition, the configuration overhead of the FPGA implementation is 1,000x more than that of REDEFINE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to develop and test new digital imaging equipment and methods for diagnosis and follow-up of ocular diseases. Methods: The whole material comprised 398 subjects (469 examined eyes), including 241 patients with melanocytic choroidal tumours, 56 patients with melanocytic iris tumours, 42 patients with diabetes, a 52-year old patient with chronic phase of VKH disease, a 30-year old patient with an old blunt eye injury, and 57 normal healthy subjects. Digital 50° (Topcon TRC 50 IA) and 45° (Canon CR6-45NM) fundus cameras, a new handheld digital colour videocamera for eye examinations (MediTell), a new subtraction method using the Topcon Image Net Program (Topcon corporation, Tokyo, Japan), a new method for digital IRT imaging of the iris we developed, and Zeiss photoslitlamp with a digital camera body were used for digital imaging. Results: Digital 50° red-free imaging had a sensitivity of 97.7% and two-field 45° and 50° colour imaging a sensitivity of 88.9-94%. The specificity of the digital 45°-50° imaging modalities was 98.9-100% versus the reference standard and ungradeable images that were 1.2-1.6%. By using the handheld digital colour video camera only, the optic disc and central fundus located inside 20° from the fovea could be recorded with a sensitivity of 6.9% for detection of at least mild NPDR when compared with the reference standard. Comparative use of digital colour, red-free, and red light imaging showed 85.7% sensitivity, 99% specificity, and 98.2 % exact agreement versus the reference standard in differentiation of small choroidal melanoma from pseudomelanoma. The new subtraction method showed growth in four of 94 melanocytic tumours (4.3%) during a mean ±SD follow-up of 23 ± 11 months. The new digital IRT imaging of the iris showed the sphincter muscle and radial contraction folds of Schwalbe in the pupillary zone and radial structural folds of Schwalbe and circular contraction furrows in the ciliary zone of the iris. The 52-year-old patient with a chronic phase of VKH disease showed extensive atrophy and occasional pigment clumps in the iris stroma, detachment of the ciliary body with severe ocular hypotony, and shallow retinal detachment of the posterior pole in both eyes. Infrared transillumination imaging and fluorescein angiographic findings of the iris showed that IR translucence (p=0.53), complete masking of fluorescence (p=0.69), presence of disorganized vessels (p=0.32), and fluorescein leakage (p=1.0) at the site of the lesion did not differentiate an iris nevus from a melanoma. Conclusions: Digital 50° red-free and two-field 50° or 45° colour imaging were suitable for DR screening, whereas the handheld digital video camera did not fulfill the needs of DR screening. Comparative use of digital colour, red-free and red light imaging was a suitable method in the differentiation of small choroidal melanoma from different pseudomelanomas. The subtraction method may reveal early growth of the melanocytic choroidal tumours. Digital IRT imaging may be used to study changes of the stroma and posterior surface of the iris in various diseases of the uvea. It contributed to the revealment of iris atrophy and serous detachment of the ciliary body with ocular hypotony together with the shallow retinal detachment of the posterior pole as new findings of the chronic phase of VKH disease. Infrared translucence and angiographic findings are useful in differential diagnosis of melanocytic iris tumours, but they cannot be used to determine if the lesion is benign or malignant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dissertation deals with remote narrowband measurements of the electromagnetic radiation emitted by lightning flashes. A lightning flash consists of a number of sub-processes. The return stroke, which transfers electrical charge from the thundercloud to to the ground, is electromagnetically an impulsive wideband process; that is, it emits radiation at most frequencies in the electromagnetic spectrum, but its duration is only some tens of microseconds. Before and after the return stroke, multiple sub-processes redistribute electrical charges within the thundercloud. These sub-processes can last for tens to hundreds of milliseconds, many orders of magnitude longer than the return stroke. Each sub-process causes radiation with specific time-domain characteristics, having maxima at different frequencies. Thus, if the radiation is measured at a single narrow frequency band, it is difficult to identify the sub-processes, and some sub-processes can be missed altogether. However, narrowband detectors are simple to design and miniaturize. In particular, near the High Frequency band (High Frequency, 3 MHz to 30 MHz), ordinary shortwave radios can, in principle, be used as detectors. This dissertation utilizes a prototype detector which is essentially a handheld AM radio receiver. Measurements were made in Scandinavia, and several independent data sources were used to identify lightning sub-processes, as well as the distance to each individual flash. It is shown that multiple sub-processes radiate strongly near the HF band. The return stroke usually radiates intensely, but it cannot be reliably identified from the time-domain signal alone. This means that a narrowband measurement is best used to characterize the energy of the radiation integrated over the whole flash, without attempting to identify individual processes. The dissertation analyzes the conditions under which this integrated energy can be used to estimate the distance to the flash. It is shown that flash-by-flash variations are large, but the integrated energy is very sensitive to changes in the distance, dropping as approximately the inverse cube root of the distance. Flashes can, in principle, be detected at distances of more than 100 km, but since the ground conductivity can vary, ranging accuracy drops dramatically at distances larger than 20 km. These limitations mean that individual flashes cannot be ranged accurately using a single narrowband detector, and the useful range is limited to 30 kilometers at the most. Nevertheless, simple statistical corrections are developed, which enable an accurate estimate of the distance to the closest edge of an active storm cell, as well as the approach speed. The results of the dissertation could therefore have practical applications in real-time short-range lightning detection and warning systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The machine replication of human reading has been the subject of intensive research for more than three decades. A large number of research papers and reports have already been published on this topic. Many commercial establishments have manufactured recognizers of varying capabilities. Handheld, desk-top, medium-size and large systems costing as high as half a million dollars are available, and are in use for various applications. However, the ultimate goal of developing a reading machine having the same reading capabilities of humans still remains unachieved. So, there still is a great gap between human reading and machine reading capabilities, and a great amount of further effort is required to narrow-down this gap, if not bridge it. This review is organized into six major sections covering a general overview (an introduction), applications of character recognition techniques, methodologies in character recognition, research work in character recognition, some practical OCRs and the conclusions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a new generation of integrated solid-state gas-sensors embedded in SOI micro-hotplates. The micro-hotplates lie on a SOI membrane and consist of MOSFET heaters that elevate the operating temperature, through self-heating, of a gas sensitive material. These sensors are fully compatible with SOI CMOS or BiCMOS technologies, offer ultra-low power consumption (under 100 mW), high sensitivity, low noise, low unit cost, reproducibility and reliability through the use of on-chip integration. In addition, the new integrated sensors offer a nearly uniform temperature distribution over the active area at its operating temperatures at up to about 300-350°C. This makes SOI-based gas-sensing devices particularly attractive for use in handheld battery-operated gas monitors. This paper reports on the design of a chemo-resistive gas sensor and proposes for the first time an intelligent SOI membrane microcalorimeter using active micro-FET heaters and temperature sensors. A comprehensive set of numerical and analogue simulations is also presented including complex 2D and 3D electro-thermal numerical analyses. © 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Screen-viewing has been associated with increased body mass, increased risk of metabolic syndrome and lower psychological well-being among children and adolescents. There is a shortage of information about the nature of contemporary screen-viewing amongst children especially given the rapid advances in screen-viewing equipment technology and their widespread availability. Anecdotal evidence suggests that large numbers of children embrace the multi-functionality of current devices to engage in multiple forms of screen-viewing at the same time. In this paper we used qualitative methods to assess the nature and extent of multiple forms of screen-viewing in UK children. Methods: Focus groups were conducted with 10-11 year old children (n = 63) who were recruited from five primary schools in Bristol, UK. Topics included the types of screen-viewing in which the participants engaged; whether the participants ever engaged in more than one form of screen-viewing at any time and if so the nature of this multiple viewing; reasons for engaging in multi-screen-viewing; the room within the house where multi-screen-viewing took place and the reasons for selecting that room. All focus groups were transcribed verbatim, anonymised and thematically analysed. Results: Multi-screen viewing was a common behaviour. Although multi-screen viewing often involved watching TV, TV viewing was often the background behaviour with attention focussed towards a laptop, handheld device or smart-phone. There were three main reasons for engaging in multi-screen viewing: 1) tempering impatience that was associated with a programme loading; 2) multi-screen facilitated filtering out unwanted content such as advertisements; and 3) multi-screen viewing was perceived to be enjoyable. Multi-screen viewing occurred either in the child's bedroom or in the main living area of the home. There was considerable variability in the level and timing of viewing and this appeared to be a function of whether the participants attended after-school clubs. Conclusions: UK children regularly engage in two or more forms of screen-viewing at the same time. There are currently no means of assessing multi-screen viewing nor any interventions that specifically focus on reducing multi-screen viewing. To reduce children's overall screen-viewing we need to understand and then develop approaches to reduce multi-screen viewing among children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we report on the successful low-temperature growth of zinc oxide nanowires (ZnONWs) on silicon-on-insulator (SOI) CMOS micro-hotplates and their response, at different operating temperatures, to hydrogen in air. The SOI micro-hotplates were fabricated in a commercial CMOS foundry followed by a deep reactive ion etch (DRIE) in a MEMS foundry to form ultra-low power membranes. The micro-hotplates comprise p+ silicon micro-heaters and interdigitated metal electrodes (measuring the change in resistance of the gas sensitive nanomaterial). The ZnONWs were grown as a post-CMOS process onto the hotplates using a CMOS friendly hydrothermal method. The ZnONWs showed a good response to 500 to 5000 ppm of hydrogen in air. We believe that the integration of ZnONWs with a MEMS platform results in a low power, low cost, hydrogen sensor that would be suitable for handheld battery-operated gas sensors. © 2011 Published by Elsevier Ltd.