961 resultados para anterior chamber depth


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. Methods: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. Results: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). Conclusions: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA) measurements that are independent of corneal thickness and curvature, and to assess variables of observer agreement. METHODS: In a multivariate cluster analysis on 223 eyes, the relationship between central corneal thickness, corneal curvature, axial length, anterior chamber depth, intraocular pressure, sex, age, and OPA measurements was assessed. Intraobserver and interobserver variabilities were calculated from repeated measurements obtained from 8 volunteers by 4 observers. RESULTS: The OPA readings were not affected by central corneal thickness (P = .08), corneal curvature (P = .47), anterior chamber depth (P = .80), age (P = .60), or sex (P = .73). There was a positive correlation between OPA and intraocular pressure (0.12 mm Hg/1 mm Hg of intraocular pressure; P<.001) and a negative correlation between OPA and axial length (0.27 mm Hg/1 mm of length; P<.001). Intraobserver and interobserver variabilities were 0.08 and 0.02 mm Hg, respectively, and the intraclass correlation coefficient was 0.89. CONCLUSIONS: The OPA readings obtained with dynamic contour tonometry in healthy subjects are not influenced by the structure of the anterior segment of the eye but are affected by intraocular pressure and axial length. We found a high amount of agreement within and between observers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: (1) To describe the ultrasonographic appearance of multiple congenital ocular anomalies (MCOA) in the eyes of horses with the PMEL17 (Silver) mutant gene. (2) To compare the accuracy of B-mode ocular ultrasound to conventional direct ophthalmoscopy. ANIMALS STUDIED: Sixty-seven Comtois and 18 Rocky Mountain horses were included in the study. PROCEDURES: Horses were classified as being carriers or noncarriers of the PMEL17 mutant allele based on coat color or genetic testing. Direct ophthalmoscopy followed by standardized ultrasonographic examination was performed in all horses. RESULTS: Seventy-five of 85 horses (88.24%) carried at least one copy of the Silver mutant allele. Cornea globosa, severe iridal hypoplasia, uveal cysts, cataracts, and retinal detachment could be appreciated with ultrasound. Carrier horses had statistically significantly increased anterior chamber depth and decreased thickness of anterior uvea compared with noncarriers (P < 0.05). Uveal cysts had a wide range of location and ultrasonographic appearances. In 51/73 (69.86%) carrier horses, ultrasound detected ciliary cysts that were missed with direct ophthalmoscopy. CONCLUSIONS: In this study, ultrasonography was useful to identify uveal cysts in PMEL17 mutant carriers and to assess anterior chamber depth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe the methodology, sampling strategy and preliminary results for the Aston Eye Study (AES), a cross-sectional study to determine the prevalence of refractive error and its associated ocular biometry in a large multi-racial sample of school children from the metropolitan area of Birmingham, England. Methods: A target sample of 1700 children aged 6–7 years and 1200 aged 12–13 years is being selected from Birmingham schools selected randomly with stratification by area deprivation index (a measure of socio-economic status). Schools with pupils predominantly (>70%) from a single race are excluded. Sample size calculations account for the likely participation rate and the clustering of individuals within schools. Procedures involve standardised protocols to allow for comparison with international population-based data. Visual acuity, non-contact ocular biometry (axial length, corneal radius of curvature and anterior chamber depth) and cycloplegic autorefraction are measured in both eyes. Distance and near oculomotor balance, height and weight are also assessed. Questionnaires for parents and older children will allow the influence of environmental factors on refractive error to be examined. Results: Recruitment and data collection are ongoing (currently N = 655). Preliminary cross-sectional data on 213 South Asian, 44 black African Caribbean and 70 white European children aged 6–7 years and 114 South Asian, 40 black African Caribbean and 115 white European children aged 12–13 years found myopia prevalence of 9.4% and 29.4% for the two age groups respectively. A more negative mean spherical equivalent refraction (SER) was observed in older children (-0.21 D vs +0.87 D). Ethnic differences in myopia prevalence are emerging with South Asian children having higher levels than white European children 36.8% vs 18.6% (for the older children). Axial length, corneal radius of curvature and anterior chamber depth were normally distributed, while SER was leptokurtic (p < 0.001) with a slight negative skew. Conclusions: The AES will allow ethnic differences in the ocular characteristics of children from a large metropolitan area of the UK to be examined. The findings to date indicate the emergence of higher levels of myopia by early adolescence in second and third generation British South Asians, compared to white European children. The continuation of the AES will allow the early determinants of these ethnic differences to be studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To demonstrate the application of low-coherence reflectometry to the study of biometric changes during disaccommodation responses in human eyes after cessation of a near task and to evaluate the effect of contact lenses on low-coherence reflectometry biometric measurements. METHODS: Ocular biometric parameters of crystalline lens thickness (LT) and anterior chamber depth (ACD) were measured with the LenStar device during and immediately after a 5 D accommodative task in 10 participants. In a separate trial, accommodation responses were recorded with a Shin-Nippon WAM-5500 optometer in a subset of two participants. Biometric data were interleaved to form a profile of post-task anterior segment changes. In a further experiment, the effect of soft contact lenses on LenStar measurements was evaluated in 15 participants. RESULTS: In 10 adult participants, increased LT and reduced ACD was seen during the 5 D task. Post-task, during fixation of a 0 D target, a profile of the change in LT and ACD against time was observed. In the two participants with accommodation data (one a sufferer of nearwork-induced transient myopia and other a non-sufferer), the post-task changes in refraction compared favorably with the interleaved LenStar biometry data. The insertion of soft contact lenses did not have a significant effect on LenStar measures of ACD or LT (mean change: -0.007 mm, p = 0.265 and + 0.001 mm, p = 0.875, respectively). CONCLUSIONS: With the addition of a relatively simple stimulus modification, the LenStar instrument can be used to produce a profile of post-task changes in LT and ACD. The spatial and temporal resolution of the system is sufficient for the investigation of nearwork-induced transient myopia from a biometric viewpoint. LenStar measurements of ACD and LT remain valid after the fitting of soft contact lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). Methods: The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Results: Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. Conclusions: The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another. © 2003 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A new commercially available optical low coherence reflectometry device (Lenstar, Haag-Streit or Allegro Biograph, Wavelight) provides high-resolution non-contact measurements of ocular biometry. The study evaluates the validity and repeatability of these measurements compared with current clinical instrumentation. Method: Measurements were taken with the LenStar and IOLMaster on 112 patients aged 41–96 years listed for cataract surgery. A subgroup of 21 patients also had A-scan applanation ultrasonography (OcuScan) performed. Intersession repeatability of the LenStar measurements was assessed on 32 patients Results: LenStar measurements of white-to-white were similar to the IOLMaster (average difference 0.06 (SD 0.03) D; p?=?0.305); corneal curvature measurements were similar to the IOLMaster (average difference -0.04 (0.20) D; p?=?0.240); anterior chamber depth measurements were significantly longer than the IOLMaster (by 0.10 (0.40) mm) and ultrasound (by 0.32 (0.62) mm; p<0.001); crystalline lens thickness measurements were similar to ultrasound (difference 0.16 (0.83) mm, p?=?0.382); axial length measurements were significantly longer than the IOLMaster (by 0.01 (0.02) mm) but shorter than ultrasound (by 0.14 (0.15) mm; p<0.001). The LensStar was unable to take measurements due to dense media opacities in a similar number of patients to the IOLMaster (9–10%). The LenStar biometric measurements were found to be highly repeatable (variability =2% of average value). Conclusions: Although there were some statistical differences between ocular biometry measurements between the LenStar and current clinical instruments, they were not clinically significant. LenStar measurements were highly repeatable and the instrument easy to use.