947 resultados para Medical Laboratory Technology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the most informative sampling time(s) providing a precise prediction of tacrolimus area under the concentration-time curve (AUC). Fifty-four concentration-time profiles of tacrolimus from 31 adult liver transplant recipients were analyzed. Each profile contained 5 tacrolimus whole-blood concentrations (predose and 1, 2, 4, and 6 or 8 hours postdose), measured using liquid chromatography-tandem mass spectrometry. The concentration at 6 hours was interpolated for each profile, and 54 values of AUC(0-6) were calculated using the trapezoidal rule. The best sampling times were then determined using limited sampling strategies and sensitivity analysis. Linear mixed-effects modeling was performed to estimate regression coefficients of equations incorporating each concentration-time point (C0, C1, C2, C4, interpolated C5, and interpolated C6) as a predictor of AUC(0-6). Predictive performance was evaluated by assessment of the mean error (ME) and root mean square error (RMSE). Limited sampling strategy (LSS) equations with C2, C4, and C5 provided similar results for prediction of AUC(0-6) (R-2 = 0.869, 0.844, and 0.832, respectively). These 3 time points were superior to C0 in the prediction of AUC. The ME was similar for all time points; the RMSE was smallest for C2, C4, and C5. The highest sensitivity index was determined to be 4.9 hours postdose at steady state, suggesting that this time point provides the most information about the AUC(0-12). The results from limited sampling strategies and sensitivity analysis supported the use of a single blood sample at 5 hours postdose as a predictor of both AUC(0-6) and AUC(0-12). A jackknife procedure was used to evaluate the predictive performance of the model, and this demonstrated that collecting a sample at 5 hours after dosing could be considered as the optimal sampling time for predicting AUC(0-6).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current approach for therapeutic drug monitoring in renal transplant recipients receiving mycophenolate mofetil (MMF) is measurement of total mycophenolic acid (MPA) concentration. Because MPA is highly bound, during hypoalbuminemia the total concentration no longer reflects the free (pharmacologically active) concentration. The authors investigated what degree of hypoalbuminemia causes a significant change in protein binding and thus percentage free MPA. Forty-two renal transplant recipients were recruited for the study. Free and total concentrations of MPA (predose, and 1, 3, and 6 hours post-MMF dose samples) and plasma albumin concentrations were determined on day 5 posttransplantation. Six-hour area under the concentration-time curve (AUC(0-6)) values were calculated for free and total MPA, and percentage free MPA was determined for each patient. The authors found a significant relationship between low albumin concentrations and increased percentage free MPA (Spearman correlation = -0.54, P < 0.0001). Receiver operating characteristic (ROC) curve analysis was performed on the albumin versus percentage free MPA data. The cutoff value of albumin determined from the ROC analysis that differentiated normal from elevated percentage free MPA (defined as greater than or equal to3%) in this patient population was 31 g/L. At this cutoff value albumin was found to be a good predictor of altered free MPA percentage, with a sensitivity and specificity of 0.75 and 0.80, respectively, and an area under the ROC curve of 0.79. To rationalize MMF dosing regimens in hypoalbuminemic patients (plasma albumin less than or equal to 31 g/L), clinicians should consider monitoring the free MPA concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pharmacokinetic disposition of metformin in late pregnancy was studied together with the level of fetal exposure at birth. Blood samples were obtained in the third trimester of pregnancy from women with gestational diabetes or type 2 diabetes, 5 had a previous diagnosis of polycystic ovary syndrome. A cord blood sample also was obtained at the delivery of some of these women, and also at delivery of others who had been taking metformin during pregnancy but from whom no blood had been taken. Plasma metformin concentrations were assayed by a new, validated, reverse-phase HPLC method, A 2-compartment, extravascular maternal model with transplacental partitioning of drug to a fetal compartment was fitted to the data. Nonlinear mixed-effects modeling was performed in'NONMEM using FOCE with INTERACTION. Variability was estimated using logarithmic interindividual and additive residual variance models; the covariance between clearance and volume was modeled simultaneously. Mean (range) metformin concentrations in cord plasma and in maternal plasma were 0.81 (range, 0.1-2.6) mg/L and 1.2 (range, 0. 1-2.9) mg/L, respectively. Typical population values (interindividual variability, CV%) for allometrically scaled maternal clearance and volume of distribution were 28 L/h/70 kg (17.1%) and 190 L/70 ka (46.3%), giving a derived population-wide half-life of 5.1 hours. The placental partition coefficient for metformin was 1.07 (36.3%). Neither maternal age nor weight significantly influenced the pharmacokinetics. The variability (SD) of observed concentrations about model-predicted concentrations was 0.32 mg/L. The pharmacokinetics were similar to those in nonpregnant patients and, therefore, no dosage adjustment is warranted. Metformin readily crosses the placenta, exposing the fetus to concentrations approaching those in the maternal circulation. The sequelae to such exposure, ea, effects on neonatal obesity and insulin resistance, remain unknown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography coupled by an electrospray ion source to a tandem mass spectrometer (HPLC-EST-MS/ MS) is the current analytical method of choice for quantitation of analytes in biological matrices. With HPLC-ESI-MS/MS having the characteristics of high selectivity, sensitivity, and throughput, this technology is being increasingly used in the clinical laboratory. An important issue to be addressed in method development, validation, and routine use of HPLC-ESI-MS/MS is matrix effects. Matrix effects are the alteration of ionization efficiency by the presence of coeluting substances. These effects are unseen in the chromatograrn but have deleterious impact on methods accuracy and sensitivity. The two common ways to assess matrix effects are either by the postextraction addition method or the postcolumn infusion method. To remove or minimize matrix effects, modification to the sample extraction methodology and improved chromatographic separation must be performed. These two parameters are linked together and form the basis of developing a successful and robust quantitative HPLC-EST-MS/MS method. Due to the heterogenous nature of the population being studied, the variability of a method must be assessed in samples taken from a variety of subjects. In this paper, the major aspects of matrix effects are discussed with an approach to address matrix effects during method validation proposed. (c) 2004 The Canadian Society of Clinical Chemists. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic kidney disease (CKD) is an increasingly common condition with limited treatment options that is placing a major financial and emotional burden on the community. The use of complementary and alternative medicines (CAMS) has increased many-fold over the past decade. Although several compelling studies show renal toxicities and an adverse outcome from use of some CAMS, there is also emerging evidence in the literature that some may be renoprotective. Many nephrologists are unaware of these potential therapeutic benefits in treating CKD, or they are reluctant to consider them in research trials for fear of adverse effects (including nephrotoxicity) or deleterious interaction with co-prescribed, conventional medicines. The increased use of self-prescribed CAMS by their patients suggests that practitioners and researchers should keep abreast of the current information on these agents. A primary goal of this article was to review the available scientific evidence for the use of herbs or natural substances as a complementary treatment for patients with CKD. A further goal was to report the literature on herbs that have been reported to cause kidney failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Plasma cholinesterase activity is known to be correlated with plasma triglycerides, HDL- and LDL-cholesterol, and other features of the metabolic syndrome. A role in triglyceride metabolism has been proposed. Genetic variants that decrease activity have been studied extensively, but the factors contributing to overall variation in the population are poorly understood. We studied plasma cholinesterase activity in a sample of 2200 adult twins to assess covariation with cardiovascular risk factors and components of the metabolic syndrome, to determine the degree of genetic effects on enzyme activity, and to search for quantitative trait loci affecting activity. Methods and Results: Cholinesterase activity was lower in women than in men before the age of 50, but increased to activity values similar to those in males after that age. There were highly significant correlations with variables associated with the metabolic syndrome: plasma triglyceride, HDL- and LDL-cholesterol, apolipoprotein B and E, urate, and insulin concentrations; gamma-glutamyltransferase and aspartate and alanine aminotransferase activities; body mass index; and blood pressure. The heritability of plasma cholinesterase activity was 65%. Linkage analysis with data from the dizygotic twin pairs showed suggestive linkage on chromosome 3 at the location of the cholinesterase WHO gene and also on chromosome 5. Conclusions: Our results confirm and extend the connection between cholinesterase, cardiovascular risk factors, and metabolic syndrome. They establish a substantial heritability for plasma cholinesterase activity that might be attributable to variation near the structural gene and at an independent locus. (c) 2006 American Association for Clinical Chemistry.