996 resultados para Air sampling


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Limited research has been conducted on the collection of bioaerosols and their health effects on individuals in the El Paso area. A year long study was conducted in the region to evaluate indoor bioaerosol concentrations (Mota et al., unpublished data). As part of the study, air samples were collected during each season for a year from 38 homes from the El Paso area. The main objective of the study was to assess seasonality differences in bioaerosol concentrations. The air samples were then cultured and analyzed for bacterial and fungal concentrations. As a supplement to that study, a health questionnaire was given during each seasonal air sampling to the participating resident to complete regarding their health status. The aim of this study was to evaluate the health questionnaire and assess any associations between the collected bioaerosol concentrations and the self-reported respiratory symptoms of the participating home residents. Symptom frequencies were tabulated and basic descriptive statistics, along with logistic regressions, were conducted on the relationship between “High” reporters of symptoms and bioaerosol concentrations and environmental factors. The most commonly reported symptoms by homeowners were nasal symptoms and allergies. In addition, there was evidence to support an association between indoor respirable bacteria concentrations and homeowners that report greater than or equal to 8 respiratory symptoms (OR=1.10, p=0.045). Smoking status, indoor humidity and season also displayed associations with homeowners that report greater than or equal to 8 respiratory symptoms (OR=3.3, p=0.045; OR=71.0, p=0.030; OR=7.2, 3.2, p=0.001, 0.008). With such a strong association, future assessment of symptoms, bioaerosol concentrations and environmental factors is needed to further establish their relationship. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Very few studies have described MUP-1 concentrations and measured prevalence of Laboratory Animal Allergy (LAA) at such a diverse institution as the private medical school (MS) that is the focus of this study. Air sampling was performed in three dissimilar animal research facilities at MS and quantitated using a commercially available ELISA. Descriptive data was obtained from an anonymous laboratory animal allergy survey given to both animal facility employees and the researchers who utilize these facilities alike. Logistic regression analysis was then implemented to investigate specific factors that may be predictive of developing LAA as well as factors influencing the reporting of LAA symptoms to the occupational health program. Concentrations of MUP-1 detected ranged from below detectable levels (BDL) to a peak of 22.64 ng/m3 . Overall, 68 employees with symptoms claimed they improved while away from work and only 25 employees reported their symptoms to occupational health. Being Vietnamese, a smoker, not wearing a mask, and working in any facility longer than one year were all significant predictors of having LAA symptoms. This study suggests a LAA monitoring system that relies on self-reporting can be inadequate in estimating LAA problems. In addition, efforts need to be made to target training and educational materials for non-native English speaking employees to overcome language and cultural barriers and address their specific needs. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in one Portuguese maternity. Sixty air samples were collected through impaction method. Air sampling was performed in food storage facilities, kitchen, food plating, canteen, pharmacy, sterilization areas, genecology wards, intensive care unit, operating rooms, urgency and also, outside premises, since this was the place regarded as reference. Besides air samples, forty three samples were collected by swabbing the surfaces using a 10 by 10 cm square stencil. Simultaneously, temperature, relative humidity and particles counting (PM10) were registered. Twenty three species of fungi were identified in air, being the two most commonly isolated the genera Penicillium (41,5%) and Cladosporium (28,4%). Regarding yeasts, only Rhodotorula sp. (45,2%), Trichosporon mucoides (51,6%) and Cryptococcus neoformans (3,2%) were found. Thirteen species of fungi were identified in surfaces, being the most frequent the Penicillium genus (91,6%). Concerning yeasts found in surfaces, four species were identified being Rhodotorula sp. (29,1%) the most frequent. There was no coincidence between prevailing genera indoors and outside premises. Moreover, some places presented fungal species different from the ones isolated outside. In the inside environment, Aspergillus species were isolated in air and surfaces. There was no significant relationship (p>0,05) between fungal contamination and the studied environmental variables. Keywords: air, surfaces, fungal contamination, environmental variables, maternity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Health effects resulting from dust inhalation in occupational environments may be more strongly associated with specific microbial components, such as fungi, than to the particles. The aim of the present study is to characterize the occupational exposure to the fungal burden in four different occupational settings (two feed industries, one poultry and one waste sorting industry), presenting results from two air sampling methods – the impinger collector and the use of filters. In addition, the equipment used for the filter sampling method allowed a more accurate characterization regarding the dimension of the collected fungal particles (less than 2.5 μm size). Air samples of 300L were collected using the impinger Coriolis μ air sampler. Simultaneously, the aerosol monitor (DustTrak II model 8532, TSI®) allowed assessing viable microbiological material below the 2.5 μm size. After sampling, filters were immersed in 300 mL of sterilized distilled water and agitated for 30 min at 100 rpm. 150 μl from the sterilized distilled water were subsequently spread onto malt extract agar (2%) with chloramphenicol (0.05 g/L). All plates were incubated at 27.5 ºC during 5–7 days. With the impinger method, the fungal load ranged from 0 to 413 CFU.m-3 and with the filter method, ranged from 0 to 64 CFU.m-3. In one feed industry, Penicillium genus was the most frequently found genus (66.7%) using the impinger method and three more fungi species/genera/complex were found. The filter assay allowed the detection of only two species/genera/complex in the same industry. In the other feed industry, Cladosporium sp. was the most found (33.3%) with impinger method and three more species/genera/complex were also found. Through the filter assay four fungi species/genera/complex were found. In the assessed poultry, Rhyzopus sp. was the most frequently detected (61.2%) and more three species/genera/complex were isolated. Through the filter assay, only two fungal species/genera/complex were found. In the waste sorting industry Penicillium sp. was the most prevalent (73.6%) with the impinger method, being isolated two more different fungi species/genera/complex. Through the filter assay only Penicillium sp. was found. A more precise determination of occupational fungal exposure was ensured, since it was possible to obtain information regarding not only the characterization of fungal contamination (impinger method), but also the size of dust particles, and viable fungal particles, that can reach the worker ́s respiratory tract (filters method). Both methods should be used in parallel to enrich discussion regarding potential health effects of occupational exposure to fungi.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Northern Ireland has approximately 1670 lakes, which cover 4.4% of the land surface. However, most of the water area is accounted for by the large lakes such as Lough Neagh (385 km2) and Lower Lough Erne (109.5 km ). The majority of lakes are less than 100 hectares in area. They tend to be distributed towards the south and west of the Province, where extensive drumlin swarms are rich in small waterbodies. In 1988-1991, 610 of the 708 lakes between one and 100 hectares were sampled by the Northern Ireland Lake Survey. The objective was to assess their conservation status based on their aquatic macrophyte flora, but in addition to extensive plant surveys, the water of each lake was analysed for a range of chemical variables. This article reports on a full-scale survey carried out in early March 2002. The survey was taken with help of two helicopters. The authorise summarise the results of the chemical analysis of the survey.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the mu g m(-3) range) and their variations with sampling site and time In this work a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE) a quick separation technique that requires nothing more than some nanoliters of sample and when combined with capacitively coupled contactless conductometric detection (C(4)D) is particularly favorable for ionic species that do not absorb in the UV-vis region like the target analytes formaldehyde formic acid acetic acid and ammonium The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry s constant such as formaldehyde and carboxylic acids or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8 3 nLs(-1)) while the sample was aspirated through the annular gap of the concentric tubes at 25 mLs(-1) A second unit in all similar to the CMDS was operated as a capillary membrane diffusion emitter (CMDE) generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS The fluids of the system were driven with inexpensive aquarium air pumps and the collected samples were stored in vials cooled by a Peltier element Complete protocols were developed for the analysis in air of NH(3) CH(3)COOH HCOOH and with a derivatization setup CH(2)O by associating the CMDS collection with the determination by CE-C(4)D The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot s reaction Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW) All techniques and methods of this work are in line with the green analytical chemistry trends (C) 2010 Elsevier B V All rights reserved

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"AEDC-TR-67-65."