492 resultados para DISINFECTION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sporicidal activity of an odour-free peracetic acid-based disinfectant (Wofasteril®) and a widely-used dichloroisocyanurate preparation (Chlor-clean®) was assessed against spores of the hyper-virulent strain of Clostridium difficile (ribotype 027), in the presence and absence of organic matter. In environmentally clean conditions, dichloroisocyanurate achieved a >3 log10 reduction in 3 minutes, but a minimum contact time of 9 minutes was required to reduce the viable spore load to below detection levels. Peracetic acid achieved a >3 log10 reduction in 30 minutes and was overall significantly less effective (P<0.05). However, in the presence of organic matter - which reflects the true clinical environment - there was no significant difference between the sporicidal activity of dichloroisocyanurate and peracetic acid over a 60-minute period (P=0.188). Given the greater occupational health hazards generally associated with chlorine-releasing agents, odour-free peracetic acid-based disinfectants may offer a suitable alternative for environmental disinfection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives Effective skin antisepsis and disinfection of medical devices are key factors in preventing many healthcare-acquired infections associated with skin microorganisms, particularly Staphylococcus epidermidis. The aim of this study was to investigate the antimicrobial efficacy of chlorhexidine digluconate (CHG), a widely used antiseptic in clinical practice, alone and in combination with tea tree oil (TTO), eucalyptus oil (EO) and thymol against planktonic and biofilm cultures of S. epidermidis. Methods Antimicrobial susceptibility assays against S. epidermidis in a suspension and in a biofilm mode of growth were performed with broth microdilution and ATP bioluminescence methods, respectively. Synergy of antimicrobial agents was evaluated with the chequerboard method. Results CHG exhibited antimicrobial activity against S. epidermidis in both suspension and biofilm (MIC 2–8 mg/L). Of the essential oils thymol exhibited the greatest antimicrobial efficacy (0.5–4 g/L) against S. epidermidis in suspension and biofilm followed by TTO (2–16 g/L) and EO (4–64 g/L). MICs of CHG and EO were reduced against S. epidermidis biofilm when in combination (MIC of 8 reduced to 0.25–1 mg/L and MIC of 32–64 reduced to 4 g/L for CHG and EO, respectively). Furthermore, the combination of EO with CHG demonstrated synergistic activity against S. epidermidis biofilm with a fractional inhibitory concentration index of <0.5. Conclusions The results from this study suggest that there may be a role for essential oils, in particular EO, for improved skin antisepsis when combined with CHG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial resistance to antibiotics and biocides is a prevalent problem, which may be exacerbated by the commonplace and often unnecessary inclusion of biocides into domestic products. Addition of antimicrobials, to domestic disinfectants has raised concern about promoting microbial resistance and potential cross-resistance to therapeutic antibiotics. This study investigated the potential for resistance in Salmonella enterica serovars Enteritidis, Typhimurium, Virchow and Escherichia call 0157 to commonly used biocides, to identify mechanisms underlying resistance and whether these provided cross-resistance to antibiotics. Salmonella enterica and E. coli 0157 strains were serially exposed to sub-inhibitory. concentrations of erythromycin (ERY), benzalkonium chloride (BKC), chlorhexidine hydrochloride (CHX)and triclosan (TLN). Once resistance was achieved permeability changes in the outer membrane, including LPS, cell surface charge and hydrophobicityand the presence of,an active efflux were investigated as possible resistance candidates. Thin layer chromatography (TLC) and Gas chromatography (GC) were carried out to examine fatty acid and lipid changes in E. coli 0157 isolates with reduced susceptibility to TLN. Cross-resistance was studied by the Stoke's method and standard microdilution assays. Examination of the outer membrane proteins and LPS did not reveal any significant changes between parent and resistant strains. The hydrophobicity of the cells increased as the cells were passaged and became less. susceptible. An active efflux system was the most likely mechanism of resistance in all strains tested and a fab1 mutation was associated with E. coli 0157 resistant to TLN isolates. In all isolates investigated the resistance was stable for over 30 passages in biocide-free media. A high degree of cross-resistance was obtained in TLN-resjstant Escherichia coli 0157 strains, which repeatedly exerted decreased susceptibility to various antimicrobials, including chloramphenicol, erythromycin, imipenem, tetracycline and trimethoprirn:, as well as to various biocides. The results of this laboratory-based investigation suggest that it is possible for microorganisms to become resistant to biocides when repeatedly exposed to sublethal concentrations. This may be especially the case in the domestic environment where administration of biocides is poorly controlled. Eventually it could lead to the undesirable situation of resident strains becoming resistant to disinfection and cross resistant to other antimicrobials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis has sought to investigate disinfection agents and procedures which may provide sanitisation against bacterial spores. A hard-surface disinfection test method was designed to ascertain which combinations of biocide and application method were most effective against bacterial spores. A combination of spraying and wiping was the most effective method of disinfection against Bacillus spores, with wiping found to play a key role in spore removal. The most efficacious of the biocides investigated was the 6% hydrogen peroxide. Vaporised Hydrogen Peroxide (VHP) gassing was more effective than traditional disinfection. In addition to efficacy, the toxic potential of the biocides to human airway epithelial cells in vitro was evaluated. Toxicity against human bronchial and nasal epithelial cells was assessed by determining cell viability, inflammatory status, protein oxidation and epithelial cell layer integrity. In addition the cell death mechanism following biocide exposure was investigated. There was a decrease in viable cells following exposure to all biocides when applied at practical concentrations. Almost all of the biocides tested elicited a pro-inflammatory response from the cells as measured by IL-8 production. All biocides increased protein oxidation as measured by thiol and carbonyl levels. Measurement of transepithelial electrical resistance and paracellular permeability indicated biocide-dependent decrease in epithelial cell barrier function. The cellular response was biased towards necrotic rather than apoptotic death. The use of biocides, although efficacious to some effects against Bacillus spores, will require careful monitoring for adverse health effects on personnel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current practice in National Health Service (NHS) hospitals employs 70% Industrial Methylated Spirit spray for surface disinfection of components required in Grade A pharmaceutical environments. This study seeks to investigate other agents and procedures that may provide more effective sanitisation. Several methods are available to test the efficacy of disinfectants against vegetative organisms. However, no methods currently available test the efficacy of disinfectants against spores on the hard surfaces encountered in the pharmacy aseptic processing environment. Therefore, a method has been developed to test the efficacy of disinfectants against spores, modified from British Standard 13697 and Association of Analytical Chemists standards. The testing procedure was used to evaluate alternative biocides and disinfection methods for transferring components into hospital pharmacy cleanrooms, and to determine which combinations of biocide and application method have the greatest efficacy against spores of Bacillus subtilis subspecies subtilis 168, Bacillus subtilis American Type Culture Collection (ATCC) 6633, and Bacillus pumilis ATCC 27142. Stainless steel carrier test plates were used to represent the hard surfaces in hospital pharmacy cleanrooms. Plates were inoculated with 10(7)-10(8) colony-forming units per milliliter (CFU/mL) and treated with the various biocide formulations, using different disinfection methods. Sporicidal activity was calculated as log reduction in CFU. Of the biocides tested, 6% hydrogen peroxide and a quaternary ammonium compound/chlorine dioxide combination were most effective compared to a Quat/biguanide, amphoteric surfactant, 70% v/v ethanol in deionised water and isopropyl alcohol in water for injection. Of the different application methods tested, spraying followed by wiping was the most effective, followed closely by wiping alone. Spraying alone was least effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper focuses on the effects of wear regime on the deposition pattern of important immunoregulatory proteins on FDA Group IV etafilcon-A lenses. Specifically, the aim was to assess the extent to which the daily disposable wear modality produces a different deposition of proteins from the conventional daily wear regime which is coupled with cleaning and disinfection. Counter immunoelectrophoresis (CIE) was employed to detect individual proteins in lens extracts from individual patients and focused on the analysis of five proteins, IgA, IgG, lactoferrin, albumin and kininogen. Deposition was monitored as a function of time; significantly lower deposition was detected on the daily disposable lenses. cr 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter describes the sites and mechanisms of action of the major groups of microbicides, relating their physical and chemical properties to interactions with microbial structures. It considers the physical, cellular and molecular methods for studying the mechanisms of action of chemical microbicides. These range from the uptake, binding and penetration of microbial cells, to the interaction with microbial structures, including the cell wall, membrane, nucleic acids, cytoplasm and enzymes. Key features of the mechanisms of action of the major groups of microbicides are described covering oxidizing agents, alkylating agents, metal ion-binding agents, nucleic acid-binding agents, protein denaturants and agents that interact with lipids. © 2013 Blackwell Publishing Ltd.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The year so far has been a slow start for many businesses, but at least we have not seen the collapse of as many businesses that we were seeing around two years ago. We are, however, still well and truly in the midst of a global recession. Interest rates are still at an all time low, UK house prices seem to be showing little signs of increase (except in London where everyone still seems to want to live!) and for the ardent shopper there are bargains to be had everywhere. It seems strange that prices on the high street do not seem to have increased in over ten years. Mobile phones, DVD players even furniture seems to be cheaper than they used to be. Whist much of this is down to cheaper manufacturing and the rest could probably be explained by competition within the market place. Does this mean that quality suffered too? Now that we live in a world when if a television is not working it is thrown away and replaced. There was a time when you would take it to some odd looking man that your father would know who could fix it for you. (I remember our local television fix-it man, with his thick rimmed bifocal spectacles and a poor comb-over; he had cardboard boxes full of resistors and electrical wires on the floor of his front room that smelt of soldering irons!) Is this consumerism at an extreme or has this move to disposability made us a better society? Before you think these are just ramblings there is a point to this. According to latest global figures of contact lens sales the vast majority of contact lenses fitted around the world are daily, fortnightly or monthly disposable hydrogel lenses. Certainly in the UK over 90% of lenses are disposable (with daily disposables being the most popular, having a market share of over 50%). This begs the question – is this a good thing? Maybe more importantly, do our patients benefit? I think it is worth reminding ourselves why we went down the disposability route with contact lenses in the first place, and unlike electrical goods it was not just so we did not have to take them for repair! There are the obvious advantages of overcoming problems of breakage and tearing of lenses and the lens deterioration with age. The lenses are less likely to be contaminated and the disinfection is either easier or not required at all (in the case of daily disposable lenses). Probably the landmark paper in the field was the work more commonly known as the ‘Gothenburg Study’. The paper, entitled ‘Strategies for minimizing the Ocular Effects of Extended Contact Lens Wear’ published in the American Journal of Optometry in 1987 (volume 64, pages 781-789) by Holden, B.A., Swarbrick, H.A., Sweeney, D.F., Ho, A., Efron, N., Vannas, A., Nilsson, K.T. They suggested that contact lens induced ocular effects were minimised by: •More frequently removed contact lenses •More regularly replaced contact lenses •A lens that was more mobile on the eye (to allow better removal of debris) •Better flow of oxygen through the lens All of these issues seem to be solved with disposability, except the oxygen issue which has been solved with the advent of silicone hydrogel materials. Newer issues have arisen and most can be solved in practice by the eye care practitioner. The emphasis now seems to be on making lenses more comfortable. The problems of contact lens related dry eyes symptoms seem to be ever present and maybe this would explain why in the UK we have a pretty constant contact lens wearing population of just over three million but every year we have over a million dropouts! That means we must be attracting a million new wearers every year (well done to the marketing departments!) but we are also losing a million wearers every year. We certainly are not losing them all to the refractive surgery clinics. We know that almost anyone can now wear a contact lens and we know that some lenses will solve problems of sharper vision, some will aid comfort, and some will be useful for patients with dry eyes. So if we still have so many dropouts then we must be doing something wrong! I think the take home message has to be ‘must try harder’! I must end with an apology for two errors in my editorial of issue 1 earlier this year. Firstly there was a typo in the first sentence; I meant to state that it was 40 years not 30 years since the first commercial soft lens was available in the UK. The second error was one that I was unaware of until colleagues Geoff Wilson (Birmingham, UK) and Tim Bowden (London, UK) wrote to me to explain that soft lenses were actually available in the UK before 1971 (please see their ‘Letters to the Editor’ in this issue). I am grateful to both of them for correcting the mistake.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The persistence of Salmonella spp. in low moisture foods is a challenge for the food industry as despite control strategies already in place, notable outbreaks still occur. The aim of this study was to characterise isolates of Salmonella, known to be persistent in the food manufacturing environment, by comparing their microbiological characteristics with a panel of matched clinical and veterinary isolates. The gross morphology of the challenge panel was phenotypically characterised in terms of cellular size, shape and motility. In all the parameters measured, the factory isolates were indistinguishable from the human, clinical and veterinary strains. Further detailed metabolic profiling was undertaken using the biolog Microbial ID system. Multivariate analysis of the metabolic microarray revealed differences in metabolism of the factory isolate of S.Montevideo, based on its upregulated ability to utilise glucose and the sugar alcohol groups. The remainder of the serotype-matched isolates were metabolically indistinguishable. Temperature and humidity are known to influence bacterial survival and through environmental monitoring experimental parameters were defined. The results revealed Salmonella survival on stainless steel was affected by environmental temperatures that may be experienced in a food processing environment; with higher survival rates (D25=35.4) at temperatures at 25°C and lower humidity levels of 15% RH, however a rapid decline in cell count (D10=3.4) with lower temperatures of 10°C and higher humidity of 70% RH. Several resident factories strains survived in higher numbers on stainless steel (D25=29.69) compared to serotype matched clinical and veterinary isolates (D25=22.98). Factory isolates of Salmonella did not show an enhanced growth rate in comparison to serotype matched solates grown in Luria broth, Nutrient broth and M9 minimal media indicating that as an independent factor, growth was unlikely to be a major factor driving Salmonella persistence. Using a live / dead stain coupled with fluorescence microscopy revealed that when no longer culturable, isolates of S.Schwarzengrund entered into a viable nonculturable state. The biofilm forming capacity of the panel was characterised and revealed that all were able to form biofilms. None of the factory isolates showed an enhanced capability to form biofilms in comparison to serotype-matched isolates. In disinfection studies, planktonic cells were more susceptible to disinfectants than cells in biofilm and all the disinfectants tested were successful in reducing bacterial load. Contact time was one of the most important factors for reducing bacterial populations in a biofilm. The genomes of eight strains were sequenced. At the nucleotide and amino acid level the food factory isolates were similar to those of isolates from other environments; no major genomic rearrangements were observed, supporting the conclusions of the phenotypic and metabolic analysis. In conclusion, having investigated a variety of morphological, biochemical and genomic factors, it is unlikely that the persistence of Salmonella in the food manufacturing environment is attributable to a single phenotypic, metabolic or genomic factor. Whilst a combination of microbiological factors may be involved it is also possible that strain persistence in the factory environment is a consequence of failure to apply established hygiene management principles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.