510 resultados para immunoassay


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to different classes of assays, antibody specificities, thresholds, test variations, and manufacturers. We aimed to assess diagnostic accuracy measures of available immunoassays and to explore sources of heterogeneity. We performed comprehensive literature searches and applied strict inclusion criteria. Finally, 49 publications comprising 128 test evaluations in 15 199 patients were included in the analysis. Methodological quality according to the revised tool for quality assessment of diagnostic accuracy studies was moderate. Diagnostic accuracy measures were calculated with the unified model (comprising a bivariate random-effects model and a hierarchical summary receiver operating characteristics model). Important differences were observed between classes of immunoassays, type of antibody specificity, thresholds, application of confirmation step, and manufacturers. Combination of high sensitivity (>95%) and high specificity (>90%) was found in 5 tests only: polyspecific enzyme-linked immunosorbent assay (ELISA) with intermediate threshold (Genetic Testing Institute, Asserachrom), particle gel immunoassay, lateral flow immunoassay, polyspecific chemiluminescent immunoassay (CLIA) with a high threshold, and immunoglobulin G (IgG)-specific CLIA with low threshold. Borderline results (sensitivity, 99.6%; specificity, 89.9%) were observed for IgG-specific Genetic Testing Institute-ELISA with low threshold. Diagnostic accuracy appears to be inadequate in tests with high thresholds (ELISA; IgG-specific CLIA), combination of IgG specificity and intermediate thresholds (ELISA, CLIA), high-dose heparin confirmation step (ELISA), and particle immunofiltration assay. When making treatment decisions, clinicians should be a aware of diagnostic characteristics of the tests used and it is recommended they estimate posttest probabilities according to likelihood ratios as well as pretest probabilities using clinical scoring tools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tick-borne encephalitis (TBE) is one of the most dangerous human neurological infections occurring in Europe and Northern parts of Asia with thousands of cases and millions vaccinated against it. The risk of TBE might be assessed through analyses of the samples taken from wildlife or from animals which are in close contact with humans. Dogs have been shown to be a good sentinel species for these studies. Serological assays for diagnosis of TBE in dogs are mainly based on purified and inactivated TBEV antigens. Here we describe novel dog anti-TBEV IgG monoclonal antibody (MAb)-capture assay which is based on TBEV prME subviral particles expressed in mammalian cells from Semliki Forest virus (SFV) replicon as well as IgG immunofluorescence assay (IFA) which is based on Vero E6 cells transfected with the same SFV replicon. We further demonstrate their use in a small-scale TBEV seroprevalence study of dogs representing different regions of Finland. Altogether, 148 dog serum samples were tested by novel assays and results were compared to those obtained with a commercial IgG enzyme immunoassay (EIA), hemagglutination inhibition test and IgG IFA with TBEV infected cells. Compared to reference tests, the sensitivities of the developed assays were 90-100% and the specificities of the two assays were 100%. Analysis of the dog serum samples showed a seroprevalence of 40% on Åland Islands and 6% on Southwestern archipelago of Finland. In conclusion, a specific and sensitive EIA and IFA for the detection of IgG antibodies in canine sera were developed. Based on these assays the seroprevalence of IgG antibodies in dogs from different regions of Finland was assessed and was shown to parallel the known human disease burden as the Southwestern archipelago and Åland Islands in particular had considerable dog TBEV antibody prevalence and represent areas with high risk of TBE for humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to investigate the properties of human acid (alpha)-glucosidase with respect to: (i) the molecular heterogeneity of the enzyme and (ii) the synthesis, post-translational modification, and transport of acid (alpha)-glucosidase in human fibroblasts.^ The initial phase of these investigations involved the purification of acid (alpha)-glucosidase from the human liver. Human hepatic acid (alpha)-glucosidase was characterized by isoelectric focusing and native and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Four distinct charge forms of hepatic acid (alpha)-glucosidase were separated by chromatofocusing and characterized individually. Charge heterogeneity was demonstrated to result from differences in the polypeptide components of each charge form.^ The second aspect of this research focused on the biosynthesis and the intracellular processing and transport of acid (alpha)-glucosidase in human fibroblasts. These experiments were accomplished by immune precipitation of the biosynthetic intermediates of acid (alpha)-glucosidase from radioactively labeled fibroblasts with polyclonal and monoclonal antibodies raised against human hepatic acid (alpha)-glucosidase. The immune precipitated biosynthetic forms of acid (alpha)-glucosidase were analyzed by SDS-PAGE and autoradiography. The pulse-chase experiments demonstrated the existence of several transient, high molecular weight precursors of acid (alpha)-glucosidase. These precursors were demonstrated to be intermediates of acid (alpha)-glucosidase at different stages of transport and processing in the Golgi apparatus. Other experiments were performed to examine the role of co-translational glycosylation of acid (alpha)-glucosidase in the transport and processing of precursors of this enzyme.^ A specific immunological assay for detecting acid (alpha)-glucosidase was developed using the monoclonal antibodies described above. This method was modified to increase the sensitivity of the assay by utilization of the biotin-avidin amplification system. This method was demonstrated to be more sensitive for detecting human acid (alpha)-glucosidase than the currently used biochemical assay for acid (alpha)-glucosidase activity. It was also demonstrated that the biotin-avidin immunoassay could discriminate between normal and acid (alpha)-glucosidase deficient fibroblasts, thus providing an alternative approach to detecting this inborn error in metabolism. (Abstract shortened with permission of author.) ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hepatitis B virus (HBV) is a significant cause of liver diseases and related complications worldwide. Both injecting and non-injecting drug users are at increased risk of contracting HBV infection. Scientific evidence suggests that drug users have subnormal response to HBV vaccination and the seroprotection rates are lower than that in the general population; potentially due to vaccine factors, host factors, or both. The purpose of this systematic review is to examine the rates of seroprotection following HBV vaccination in drug using populations and to conduct a meta-analysis to identify the factors associated with varying seroprotection rates. Seroprotection is defined as developing an anti-HBs antibody level of ≥ 10 mIU/ml after receiving the HBV vaccine. Original research articles were searched using online databases and reference lists of shortlisted articles. HBV vaccine intervention studies reporting seroprotection rates in drug users and published in English language during or after 1989 were eligible. Out of 235 citations reviewed, 11 studies were included in this review. The reported seroprotection rates ranged from 54.5 – 97.1%. Combination vaccine (HAV and HBV) (Risk ratio 12.91, 95% CI 2.98-55.86, p = 0.003), measurement of anti-HBs with microparticle immunoassay (Risk ratio 3.46, 95% CI 1.11-10.81, p = 0.035) and anti-HBs antibody measurement at 2 months after the last HBV vaccine dose (RR 4.11, 95% CI 1.55-10.89, p = 0.009) were significantly associated with higher seroprotection rates. Although statistically nonsignificant, the variables mean age>30 years, higher prevalence of anti-HBc antibody and anti-HIV antibody in the sample population, and current drug use (not in drug rehabilitation treatment) were strongly associated with decreased seroprotection rates. Proportion of injecting drug users, vaccine dose and accelerated vaccine schedule were not predictors of heterogeneity across studies. Studies examined in this review were significantly heterogeneous (Q = 180.850, p = 0.000) and factors identified should be considered when comparing immune response across studies. The combination vaccine showed promising results; however, its effectiveness compared to standard HBV vaccine needs to be examined systematically. Immune response in DUs can possibly be improved by the use of bivalent vaccines, booster doses, and improving vaccine completion rates through integrated public programs and incentives.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Family members of Enterobacteriaceae are found in small numbers associated with acute diarrhea. These species are sometimes mistaken for ETEC. ^ Methods: Forty-four non-E. coli species from travelers' diarrhea are compared to 30 strains of Escherichia coli (ETEC) and 30 strains of normal flora E. coli. Tissue culture supernatants were assayed by enzyme-linked immunosorbent assay for amounts of IL-8, IL-1, and IL-1ra. Amounts of heat-stable (ST) and heat-labile (LT) enterotoxins were assayed from cell culture supernatants by enzyme-linked immunoassay. PCR was use to determine which species was positive colonization factor antigens, CFA/I, CS3, and CS6. ^ Results: Normal flora E. coli significantly induced the production of more IL-8 than non- E. coli and ETEC. Normal E. coli also induced the production of more IL-1and IL-1ra than ETEC. Non-E. coli produced more ST than ETEC. A small percentage of enterotoxigenic non- E. coli gram negatives and ETEC were positive for CFA/I and CS6. None of the strains were positive for CS3. ^ Conclusions: Non-E. coli enterotoxigenic gram negatives were similar to ETEC in their virulence factors. Identification and further study of these non-E.coli strains is important for understanding their pathogenic role in acute diarrhea.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de la presente tesis doctoral es el desarrollo de un nuevo concepto de biosensor óptico sin marcado, basado en una combinación de técnicas de caracterización óptica de interrogación vertical y estructuras sub-micrométricas fabricadas sobre chips de silicio. Las características más importantes de dicho dispositivo son su simplicidad, tanto desde el punto de vista de medida óptica como de introducción de las muestras a medir en el área sensible, aspectos que suelen ser críticos en la mayoría de sensores encontrados en la literatura. Cada uno de los aspectos relacionados con el diseño de un biosensor, que son fundamentalmente cuatro (diseño fotónico, caracterización óptica, fabricación y fluídica/inmovilización química) son desarrollados en detalle en los capítulos correspondientes. En la primera parte de la tesis se hace una introducción al concepto de biosensor, en qué consiste, qué tipos hay y cuáles son los parámetros más comunes usados para cuantificar su comportamiento. Posteriormente se realiza un análisis del estado del arte en la materia, enfocado en particular en el área de biosensores ópticos sin marcado. Se introducen también cuáles son las reacciones bioquímicas a estudiar (inmunoensayos). En la segunda parte se describe en primer lugar cuáles son las técnicas ópticas empleadas en la caracterización: Reflectometría, Elipsometría y Espectrometría; además de los motivos que han llevado a su empleo. Posteriormente se introducen diversos diseños de las denominadas "celdas optofluídicas", que son los dispositivos en los que se va a producir la interacción bioquímica. Se presentan cuatro dispositivos diferentes, y junto con ellos, se proponen diversos métodos de cálculo teórico de la respuesta óptica esperada. Posteriormente se procede al cálculo de la sensibilidad esperada para cada una de las celdas, así como al análisis de los procesos de fabricación de cada una de ellas y su comportamiento fluídico. Una vez analizados todos los aspectos críticos del comportamiento del biosensor, se puede realizar un proceso de optimización de su diseño. Esto se realiza usando un modelo de cálculo simplificado (modelo 1.5-D) que permite la obtención de parámetros como la sensibilidad y el límite de detección de un gran número de dispositivos en un tiempo relativamente reducido. Para este proceso se escogen dos de las celdas optofluídicas propuestas. En la parte final de la tesis se muestran los resultados experimentales obtenidos. En primer lugar, se caracteriza una celda basada en agujeros sub-micrométricos como sensor de índice de refracción, usando para ello diferentes líquidos orgánicos; dichos resultados experimentales presentan una buena correlación con los cálculos teóricos previos, lo que permite validar el modelo conceptual presentado. Finalmente, se realiza un inmunoensayo químico sobre otra de las celdas propuestas (pilares nanométricos de polímero SU-8). Para ello se utiliza el inmunoensayo de albumina de suero bovino (BSA) y su anticuerpo (antiBSA). Se detalla el proceso de obtención de la celda, la funcionalización de la superficie con los bioreceptores (en este caso, BSA) y el proceso de biorreconocimiento. Este proceso permite dar una primera estimación de cuál es el límite de detección esperable para este tipo de sensores en un inmunoensayo estándar. En este caso, se alcanza un valor de 2.3 ng/mL, que es competitivo comparado con otros ensayos similares encontrados en la literatura. La principal conclusión de la tesis es que esta tipología de dispositivos puede ser usada como inmunosensor, y presenta ciertas ventajas respecto a los actualmente existentes. Estas ventajas vienen asociadas, de nuevo, a su simplicidad, tanto a la hora de medir ópticamente, como dentro del proceso de introducción de los bioanalitos en el área sensora (depositando simplemente una gota sobre la micro-nano-estructura). Los cálculos teorícos realizados en los procesos de optimización sugieren a su vez que el comportamiento del sensor, medido en magnitudes como límite de detección biológico puede ser ampliamente mejorado con una mayor compactación de pilares, alcanzandose un valor mínimo de 0.59 ng/mL). The objective of this thesis is to develop a new concept of optical label-free biosensor, based on a combination of vertical interrogation optical techniques and submicron structures fabricated over silicon chips. The most important features of this device are its simplicity, both from the point of view of optical measurement and regarding to the introduction of samples to be measured in the sensing area, which are often critical aspects in the majority of sensors found in the literature. Each of the aspects related to the design of biosensors, which are basically four (photonic design, optical characterization, fabrication and fluid / chemical immobilization) are developed in detail in the relevant chapters. The first part of the thesis consists of an introduction to the concept of biosensor: which elements consists of, existing types and the most common parameters used to quantify its behavior. Subsequently, an analysis of the state of the art in this area is presented, focusing in particular in the area of label free optical biosensors. What are also introduced to study biochemical reactions (immunoassays). The second part describes firstly the optical techniques used in the characterization: reflectometry, ellipsometry and spectrometry; in addition to the reasons that have led to their use. Subsequently several examples of the so-called "optofluidic cells" are introduced, which are the devices where the biochemical interactions take place. Four different devices are presented, and their optical response is calculated by using various methods. Then is exposed the calculation of the expected sensitivity for each of the cells, and the analysis of their fabrication processes and fluidic behavior at the sub-micrometric range. After analyzing all the critical aspects of the biosensor, it can be performed a process of optimization of a particular design. This is done using a simplified calculation model (1.5-D model calculation) that allows obtaining parameters such as sensitivity and the detection limit of a large number of devices in a relatively reduced time. For this process are chosen two different optofluidic cells, from the four previously proposed. The final part of the thesis is the exposition of the obtained experimental results. Firstly, a cell based sub-micrometric holes is characterized as refractive index sensor using different organic fluids, and such experimental results show a good correlation with previous theoretical calculations, allowing to validate the conceptual model presented. Finally, an immunoassay is performed on another typology of cell (SU-8 polymer pillars). This immunoassay uses bovine serum albumin (BSA) and its antibody (antiBSA). The processes for obtaining the cell surface functionalization with the bioreceptors (in this case, BSA) and the biorecognition (antiBSA) are detailed. This immunoassay can give a first estimation of which are the expected limit of detection values for this typology of sensors in a standard immunoassay. In this case, it reaches a value of 2.3 ng/mL, which is competitive with other similar assays found in the literature. The main conclusion of the thesis is that this type of device can be used as immunosensor, and has certain advantages over the existing ones. These advantages are associated again with its simplicity, by the simpler coupling of light and in the process of introduction of bioanalytes into the sensing areas (by depositing a droplet over the micro-nano-structure). Theoretical calculations made in optimizing processes suggest that the sensor Limit of detection can be greatly improved with higher compacting of the lattice of pillars, reaching a minimum value of 0.59 ng/mL).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of cross-reactivity in allergy is key to both understanding. the allergic response of many patients and providing them with a rational treatment In the present study, protein microarrays and a co-sensitization graph approach were used in conjunction with an allergen microarray immunoassay. This enabled us to include a wide number of proteins and a large number of patients, and to study sensitization profiles among members of the LTP family. Fourteen LTPs from the most frequent plant food-induced allergies in the geographical area studied were printed into a microarray specifically designed for this research. 212 patients with fruit allergy and 117 food-tolerant pollen allergic subjects were recruited from seven regions of Spain with different pollen profiles, and their sera were tested with allergen microarray. This approach has proven itself to be a good tool to study cross-reactivity between members of LTP family, and could become a useful strategy to analyze other families of allergens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cross-reactivity of plant foods is an important phenomenon in allergy, with geographical variations with respect to the number and prevalence of the allergens involved in this process, whose complexity requires detailed studies. We have addressed the role of thaumatin-like proteins (TLPs) in cross-reactivity between fruit and pollen allergies. A representative panel of 16 purified TLPs was printed onto an allergen microarray. The proteins selected belonged to the sources most frequently associated with peach allergy in representative regions of Spain. Sera from two groups of well characterized patients, one with allergy to Rosaceae fruit (FAG) and another against pollens but tolerant to food-plant allergens (PAG), were obtained from seven geographical areas with different environmental pollen profiles. Cross-reactivity between members of this family was demonstrated by inhibition assays. Only 6 out of 16 purified TLPs showed noticeable allergenic activity in the studied populations. Pru p 2.0201, the peach TLP (41%), chestnut TLP (24%) and plane pollen TLP (22%) proved to be allergens of probable relevance to fruit allergy, being mainly associated with pollen sensitization, and strongly linked to specific geographical areas such as Barcelona, Bilbao, the Canary Islands and Madrid. The patients exhibited mayor que50% positive response to Pru p 2.0201 and to chestnut TLP in these specific areas. Therefore, their recognition patterns were associated with the geographical area, suggesting a role for pollen in the sensitization of these allergens. Finally, the co-sensitizations of patients considering pairs of TLP allergens were analyzed by using the co-sensitization graph associated with an allergen microarray immunoassay. Our data indicate that TLPs are significant allergens in plant food allergy and should be considered when diagnosing and treating pollen-food allergy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Label free immunoassay sector is a ferment of activity, experiencing rapid growth as new technologies come forward and achieve acceptance. The landscape is changing in a “bottom up” approach, as individual companies promote individual technologies and find a market for them. Therefore, each of the companies operating in the label-free immunoassay sector offers a technology that is in some way unique and proprietary. However, no many technologies based on Label-free technology are currently in the market for PoC and High Throughput Screening (HTS), where mature labeled technologies have taken the market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous work of the research group [1-4] demonstrated the viability of using periodic lattices of micro and nanopillars, called Bio-photonic sensing Cells (BICELLs), as an optical biosensor vertically characterized by visible spectrometry. Also we have studied theoretically [5] the performance of the BICELLs by 2D and 3D simulation in orde r to optimize the biosensing response. In this work we present the fabrication and biosensing comparison of different geometrical parameters on periodic lattices of pillars in order to discuss theoretical conclusions with these results. In this way, we have explored the biosensing response of other patter ns such as crosses, stars, cylinders, concentrical cylinders (Figure 1). Also we introduced a novel method to test the BICELLs in a cost-effective way by using an ultra-thin film of SU-8 spin-coated onto the patterns to reproduce the effect of a biofilm attached to the biosensor surface. Finally we have tested the biosensing response of the different geometries by the well-known Bovine Serum Albumin (BSA) immunoassay and compared with the theoretical simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de esta tesis es el desarrollo y caracterización de biosensores ópticos sin marcado basados en celdas sensoras biofotónicas (BICELLs). Éstas son un nuevo concepto de biosensor desarrollado por el grupo de investigación y consiste en la combinación de técnicas de interrogación vertical, junto a estructuras fotónicas producidas usando métodos de micro- y nanofabricación. Varias conclusiones son extraídas de este trabajo. La primera, que se ha definido una BICELL estándar basada en interferómetros Fabry-Perot (FP). Se ha demostrado su capacidad para la comparación de rendimiento entre BICELLs estructuradas y para la realización de inmunoensayos de bajo coste. Se han estudiado diferentes técnicas de fabricación disponibles para la producción de BICELLs. Se determinó que la litografía de contacto a nivel de oblea produce estructuras de bajo coste, reproducibles y de alta calidad. La resolución alcanzada ha sido de 700 nm. El estudio de la respuesta a inmunoensayos de las BICELLs producidas se ha desarrollado en este trabajo. Se estudió la influencia de BICELLs basadas en diferentes geometrías y tamaños. De aquí resulta un nuevo enfoque para predecir el comportamiento de respuesta para la detección biológica de cualquier biosensor óptico estructurado, relacionando su superficie efectiva y su sensibilidad óptica. También se demostró una técnica novedosa y de bajo coste para la caracterización experimental de la sensibilidad óptica, basada en el depósito de películas ultradelgadas. Finalmente, se ha demostrado el uso de BICELLs desarrolladas en esta tesis, en la detección de aplicaciones reales, tales como hormonas, virus y proteínas. ABSTRACT The objective of this thesis is the development and characterization of optical label-free biosensors based on Bio-Photonic sensing Cells (BICELLs). BICELL is a novel biosensor concept developed by the research group, and it consists of a combination of vertical interrogation optical techniques and photonic structures produced by using micro- and nano-fabrication methods. Several main conclusions are extracted from this work. Firstly, a standard BICELL is defined based on FP interferometers, which demonstrated its capacity for accomplishing performance comparisons among different structured BICELLs, as well as to achieve low-cost immunoassays. Different available fabrication techniques were studied for BICELL manufacturing. It is found that contact lithography at wafer scale produce cost-effective, reproducible and high quality structures. The resolution achieved was 700 nm. Study on the response of developed BICELLs to immunoassays is performed within this work. It is therefore studied the influence of BICELLs based on different geometries and sizes in the immunoassay, which resulted in a new approach to predict the biosensing behaviour of any structured optical biosensor relating to its effective surface and optical sensitivity. Also, it is demonstrated a novel and low-cost characterization technique of the experimental optical sensitivity, based on ultrathin-film deposition. Finally, it is also demonstrated the capability of using the developed BICELLs in this thesis for real applications detection of hormones, virus and proteins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El núcleo fundamental de esta tesis doctoral es un modelo teórico de la interacción de la luz con un tipo particular de biosensor óptico. Este biosensor se compone de dos regiones: en la región inferior puede haber capas de materiales con diferentes espesores y propiedades ópticas, apiladas horizontalmente; en la zona superior, sobre la que incide directamente el haz de luz, puede haber estructuras que hacen que las propiedades ópticas cambien tanto en el plano horizontal como en la dirección vertical. Estos biosensores responden ópticamente de forma diferente al ser iluminados dependiendo de que su superficie externa esté, en mayor o menor medida, recubierta con diferentes tipos de material biológico. En esta tesis se define un modelo analítico aproximado que permite simular la respuesta óptica de biosensores con estructuras en su región más externa. Una vez comprobada la validez práctica del modelo mediante comparación con medidas experimentales, éste se utiliza en el diseño de biosensores de rendimiento óptimo y en la definición de nuevas técnicas de interrogación óptica. En particular, el sistema de transducción IROP (Increased Relative Optical Power), basado en el efecto que produce la presencia de material biológico, en la potencia total reflejada por la celda biosensora en determinados intervalos espectrales, es uno de los sistemas que ha sido patentado y es objeto de desarrollo por la empresa de base tecnológica BIOD [www.biod.es/], estando ya disponibles en este momento varios dispositivos de diagnóstico basados en esta idea. Los dispositivos basados en este sistema de transducción han demostrado su eficiencia en la detección de proteínas y agentes infecciosos como los rotavirus y el virus del dengue. Finalmente, el modelo teórico desarrollado se utiliza para caracterizar las propiedades ópticas de algunos de los materiales de los que se fabrican los biosensores, así como las de las capas de material biológico formadas en las diferentes fases de un inmunoensayo. Los parámetros ópticos de las capas mencionadas se obtienen mediante el método general de ajuste por mínimos cuadrados a las curvas experimentales obtenidas en los inmunoensayos. ABSTRACT The core of this thesis is the theoretical modeling of the interaction of light with a particular type of optical biosensor. This biosensor consists of two parts: in the lower region may have layers of materials with different thicknesses and optical properties, stacked horizontally; at the top, on which directly affects the light beam, there may be structures that make optical properties change in both, the horizontal and in the vertical direction. These biosensors optically respond differently when illuminated depending on its external surface is greater or lesser extent, coated with different types of biological material. In this thesis an approximate analytical model to simulate the optical response of biosensors with structures in its outer region is defined. After verifying the practical validity of the model by comparison with experimental measurements, it is used in the design of biosensors with optimal performance and the definition of new optical interrogation techniques. In particular, the transduction system IROP (Increased Relative Optical Power) based on the effect of the presence of biological material in the total power reflected from the biosensor cell in certain spectral ranges, has been patented and is under development by the startup company BIOD [www.biod.es/], being already available at this time, several diagnostic devices based on this idea. Devices based on this transduction system have proven their efficiency in detecting proteins and infectious agents such as rotavirus and virus of dengue. Finally, the developed theoretical model is used to characterize the optical properties of some of the materials from which biosensors are fabricated, as well as the optical properties of the biological material layers formed at different stages of an immunoassay. The optical parameters of the layers above are obtained by the general method of least squares fit to the experimental curves obtained in immunoassays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of an ovulation-inducing factor (OIF) in the seminal plasma (SP) of several species with spontaneous and induced ovulation, including the rabbit, has been documented. Recent studies have demonstrated that the OIF in the SP of camels (SPCAM) is a nerve growth factor (β-NGF). The aim of this study was to determine if purified β-NGF from mouse submandibular glands or SPCAM could provoke ovulation induction in the rabbit doe. A total of 35 females were synchronized with 25 IU of equine chorionic gonadotropin (Serigan, Laboratorios Ovejero, Spain) and allocated into 4 groups. Forty-eight hours later (Day 0), does were given a single dose (IM) of 1 mL of saline solution (SS; n = 8); 1 mL of gonadorelin (GnRH; Inducel, Laboratorios Ovejero, Spain; n = 9); 24 µg of β-NGF (2.5S-NGF; Promega, USA; n = 10); or 1 mL of centrifuged raw camel SP (SPCAM; 127 pg mL–1 NGF; n = 8). After treatment, an empty catheter was introduced through the vagina to simulate the nervous/mechanical stimulus of coitus (4 animals per group). Plasma LH concentrations were determined in blood samples taken 30 min before treatment and at 0, 30, 60, 90, and 120 min after injection. Progesterone concentrations were assessed at 0 and 120 min and every 2 days until Day 6 after treatment. Concentrations of β-NGF in camel SP and hormone determinations were made by enzyme immunoassay. Ovulation rate (OR) was determined after euthanasia on Day 7.