958 resultados para FLOW-INJECTION ANALYSIS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and sensitive method for the determination of psilocin and psilocybin is described. This is the first report on the determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence. The limits of detection (signal-to-noise ratio = 3) are 9 × 10−10 M and 3 × 10−10 M for psilocin and psilocybin, respectively.A concise synthetic route for psilocin in three steps from readily available starting materials is also described. The structures were elucidated on the basis of spectroscopic data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selective determination of morphine in the larvae of Calliphora stygia (Fabricius) (Diptera: Calliphoridae) using acidic potassium permanganate chemiluminescence detection coupled with flow injection analysis and high-performance liquid chromatography (HPLC) is described. Larvae of C. stygia were reared on minced meat substrates that had been spiked with varying concentrations of morphine. Morphine concentrations were chosen to reflect typical levels in human tissues from opiate overdose victims. After maturing on substrates, larvae were analyzed for the presence of morphine using chemiluminescence detection coupled to flow injection analysis and a rapid HPLC method. Analysis of the larval matrix by flow injection analysis with chemiluminescence detection indicated the presence of interferants capable of generating chemiluminescence. A rapid chromatographic separation with a monolithic column allowed selective determination of morphine in larvae using postcolumn chemiluminescence detection. Larvae of C. stygia reared on substrates containing morphine at concentrations of 500 and 1000 ng/g did not sequester morphine at detectable concentrations. Larvae reared on substrates containing morphine concentrations of 2500, 5000, and 10,000 ng/g tested positive for the drug at concentrations of 765, 2720, and 3010 ng/g, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel chemiluminescence flow injection procedure for the determination of As(III) in aqueous samples is described. The method involves injection of As(III) samples into a 1% (m/v) sodium hexametaphosphate in 0.02 M H2SO4 carrier stream, which then merges at a Y-piece with a reagent stream consisting of potassium permanganate (5.0 × 10−5 M) made up in the acidic sodium hexametaphosphate carrier solution. The chemiluminescence intensity of the resulting reaction mixture was measured at a photomultiplier tube operated at a voltage of 0.93 kV. Under optimized conditions, the method is characterised by a linear range from 0.5 to 5.0 μg l−1, a detection limit of 0.3 μg l−1 and a sampling frequency of 150 h−1. The effects of common anionic and cationic interferences were investigated, and it was found that the only ions to cause serious interference were those which react with potassium permanganate, namely sulphide, iodide and ferrous.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have examined a range of new and previously described flow cells for chemiluminescence detection. The reactions of acidic potassium permanganate with morphine and amoxicillin were used as model systems representing the many fast chemiluminescence reactions between oxidising agents and organic analytes, and the preliminary partial reduction of the reagent was exploited to further increase the rates of reaction. The comparison was then extended to high-performance liquid chromatography separations of α- and β-adrenergic agonists, with permanganate chemiluminescence detection. Flow cells constructed by machining novel channel designs into white polymer materials (sealed with transparent films or plates) have enabled improvements in mixing efficiency and overall transmission of light to the photodetector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae) roots and barks by Liquid Chromatography - Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a new methodology for the construction of very efficient flow cells for mercury detection by potentiometric stripping analysis, employing the thin gold layer of recordable CDs as working electrode is reported. This new source of electrodes (CDtrodes) show very attractive performance, similar to that obtained with commercial gold electrodes, with superior versatility. The low cost of this new source of gold electrodes allows a frequent replacement of the electrode, avoiding cumbersome clean-up treatments. Various experimental parameters have been optimized to yield low detection limits (0.25 ng/mL of mercury for 5 min deposition at 0.3 V) and good precision (standard deviation of 1.9% was obtained for 15 repetitive measurements using 10 ng/mL of mercury). Standard curves were found to be linear over the range of 0.5-100 μg L-1 of mercury. The flow cells developed were used for the quantification of mercury in oceanic and tap water. © Springer-Verlag 2000.