422 resultados para orthopedic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nickel, a component of stainless steels (SS) applied in orthopedic implants may cause allergic processes in human tissues P558 nickel free SS was studied to verify its viability as a substitute for stainless steel containing nickel Its performance is compared to ISO 5832-9 and F138 most used nowadays grades in implants fabrications, in minimum essential medium. MEM, at 37 degrees C. Potentiodynamic polarization curves, electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and ""in vitro"" cytotoxicity were used as techniques. From the electrochemical point of view P558 SS is comparable to ISO 5832-9 SS in MEM It remains passivated until the transpassivation potential, above which generalized corrosion occurs F138 presents pitting corrosion at 370 mV/SCE. The cytotoxicity results showed that P558. ISO 5832-9 and F138 do not present cytotoxic character Therefore, these results suggest that P558 SS can be applied in orthopedic implants (C) 2010 Elsevier BV All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Medical Outcomes General Health Survey (SF-36) is a widely used health status measure; however, limited evidence is available for its performance in orthopedic settings. The aim of this study was to examine the magnitude and meaningfulness of change and sensitivity of SF-36 subscales following orthopedic surgery.

Methods: Longitudinal data on outcomes of total hip replacement (THR, n = 255), total knee replacement (TKR, n = 103), arthroscopic partial meniscectomy (APM, n = 74) and anterior cruciate ligament reconstruction (ACL, n = 62) were used to estimate the effect sizes (ES, magnitude of change) and minimal detectable change (sensitivity) at the group and individual level. To provide context for interpreting the magnitude of changes in SF-36 scores, we also compared patients' scores with age and sex-matched population norms. The studies were conducted in Sweden. Follow-up was five years in THR and TKR studies, two years in ACL, and three months in APM.

Results:
On average, large effect sizes (ES≥0.80) were found after orthopedic surgery in SF-36 subscales measuring physical aspects (physical functioning, role physical, and bodily pain). Small (0.20–0.49) to moderate (0.50–0.79) effect sizes were found in subscales measuring mental and social aspects (role emotional, vitality, social functioning, and mental health). General health scores remained relatively unchanged during the follow-up. Despite improvements, post-surgery mean scores of patients were still below the age and sex matched population norms on physical subscales. Patients' scores on mental and social subscales approached population norms following the surgery. At the individual level, scores of a large proportion of patients were affected by floor or ceiling effects on several subscales and the sensitivity to individual change was very low.

Conclusion: Large to moderate meaningful changes in group scores were observed in all SF-36 subscales except General Health across the intervention groups. Therefore, in orthopedic settings, the SF-36 can be used to show changes for groups in physical, mental, and social dimensions and in comparison with population norms. However, SF-36 subscales have low sensitivity to individual change and so we caution against using SF-36 to monitor the health status of individual patients undergoing orthopedic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti–6Al–4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti–6Al–4V. The sol–gel method was used to produce the coatings and the thermal properties, phase composition, microstructure, thickness, surface roughness and adhesion strength of sphene coatings were analyzed by differential thermal analysis–thermal gravity (DTA–TG), X-ray diffraction (XRD), scanning electron microscopy (SEM), atom force microscopy (AFM) and scratch test, respectively. DTA analysis confirmed that the temperature of the sphene phase formation is 875 °C and XRD analysis indicated pure sphene coatings were obtained. A uniform structure of the sphene coating was found across the Ti–6Al–4V surface, with a thickness and surface roughness of the coating of about 0.5–1 μm and 0.38 μm, respectively. Sphene-coated Ti–6Al–4V possessed a significantly improved adhesion strength compared to that for HAp coating and their chemical stability was evaluated by testing the profile element distribution and the dissolution kinetics of calcium (Ca) ions after soaking the sphene-coated Ti–6Al–4V in Tris–HCl solution. Sphene coatings had a significantly improved chemical stability compared to the HAp coatings. A layer of apatite formed on the sphene-coated Ti–6Al–4V after they were soaked in simulated body fluids (SBF). Our results indicate that sol–gel coating of novel sphene onto Ti–6Al–4V possessed improved adhesion strength and chemical stability, compared to HAp-coated Ti–6Al–4V prepared under the same conditions, suggesting their potential application as coatings for orthopedic implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: O ximelagatrano foi recentemente estudada para profilaxia do tromboembolismo venoso (TEV). OBJETIVO: Avaliar se o ximelagatrano comparado com a varfarina melhora a profilaxia do TEV em pacientes submetidos à cirurgia ortopédica do joelho. FONTE DE DADOS: Estudos randomizados identificados por pesquisa eletrônica na literatura médica, até 2006, cujos dados foram compilados no programa Review Manager, versão 4.2.5. RESULTADOS: Foram incluídos três estudos randomizados bem conduzidos envolvendo 4.914 participantes. Foram definidos dois sub-grupos com dosagens diferentes de ximelagatrano (24 mg and 36 mg, duas vezes ao dia). O tratamento com ximelagatrano mostrou freqüência significantemente menor de TEV que o tratamento com varfarina, mas somente na dosagem de 36-mg [risco relativo, RR 0.72 ([intervalo de confiança, IC, 95% 0.64, 0.81), p < 0.00001]. A freqüência de TEV no sub-grupo de 24-mg foi similar a da varfarina [RR 0.86 (IC 95% 0.73, 1.01), p = 0.06]. Para TEV maior, embolia pulmonar, sangramento e sangramento maior não houve diferença entre varfarina e a ximelagatrano. Ao final do tratamento, a elevação da alanino-aminotransferase (ALT) foi menos freqüente no sub-grupo de 24 mg de ximelagatrano que no grupo da varfarina [RR 0.33 (IC 95% 0.12, 0.91) p = 0.03], mas no período de acompanhamento essa elevação foi maior com 36 mg de ximelagatrano [RR 6.97 (IC 95% 1.26, 38.50) p = 0.03]. CONCLUSÃO: O ximelagatrano foi mais efetivo que a varfarina quando usado em dosagens maiores (36 mg, 2 vezes ao dia), mas às expensas de aumento de enzimas hepáticas no período de acompanhamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fios de sutura de náilon (0, 3-0 e 4-0), poliéster trançado (0, 3-0 e 4-0) e polipropileno (0, 3-0 e 4-0) de 7 marcas comercializadas no Brasil, foram submetidos a análise de diâmetro, comprimento, resistência do encastoamento, resistência à tração do fio sem nó e resistência à tração do fio com nó, segundo metodologia padronizada pela Associação Brasileira de Normas Técnicas (ABNT). Os resultados obtidos indicam que a maioria dos fios testados encontra-se dentro dos valores preconizados pela ABNT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Nowadays, research on orthopedic and dental implants is focused on titanium alloys for their mechanical properties and corrosion resistance in the human body environment. Another important aspect to be investigated is their surface topography, which is very important to osseointegration. With laser beam irradiation for roughening the implants surface an easier control of the microtopography is achieved, and surface contamination is avoided. The aim of this study was to assess human bone marrow stem cells response to a newly developed titanium alloy, Ti-15Mo, with surface topography modified by laser beam irradiation. Materials and methods: A total of 10 Ti machined disks (control), 10 Ti-15Mo machined disks and 10 Ti-15Mo disks treated by laser beam-irradiation were prepared. To study how Ti-15Mo surface topografy can induce osteoblast differentiation in mesenchymal stem cells, the expression levels of bone related genes and mesenchymal stem cells marker were analyzed, using real time Reverse Transcription-Polymerase Chain Reaction. Results: In Test 1 (comparison between Ti-15Mo machined disks and Ti-machined disks) quantitative real-time RT-PCR showed a significant induction of ALPL, FOSL1 and SPP1, which increase 20% or more. In Test 2 (comparison between Ti-15Mo laser treated disks and Ti-machined disks) all investigated genes were up-regulated. By comparing Test 1 and Test 2 it was detected that COL1A1, COL3A1, FOSL1 and ENG sensibly increased their expression whereas RUNX2, ALPL and SPP1 expression remained substantially unchanged. Conclusion: The present study demonstrated that laser treated Ti-15Mo alloys are promising materials for implants application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In the past 10 years, new anticoagulants (NACs) have been studied for venous thromboembolism (VTE) prophylaxis. Objective: To evaluate the risk/benefit profile of NACs versus enoxaparin for VTE prophylaxis in major orthopedic surgery. Methods: A systematic review of double-blind randomized phase III studies was performed. The search strategy was run from 2000 to 2011 in the main medical electronic databases in any language. Independent extraction of articles was performed by 2 authors using predefined data fields, including study quality indicators. Results: Fifteen published clinical trials evaluating fondaparinux, rivaroxaban, dabigatran, and apixaban were included. Primary efficacy (any deep vein thrombosis [DVT], nonfatal pulmonary embolism, or all-cause mortality) favored fondaparinux (relative risk [RR] 0.50; 95% CI, 0.39, 0.63) and rivaroxaban (RR, 0.50; 95% CI, 0.34, 0.73) over enoxaparin, although significant heterogeneity was observed in both series. The primary efficacy of dabigatran at 220 mg, apixaban, and bemiparin were similar, with RRs of 1.02 (95% CI, 0.86, 1.20), 0.63 (95% CI, 0.39, 1.01), and 0.87 (95% CI, 0.65, 1.17), respectively. The primary efficacy of dabigatran at 150 mg (RR, 1.20; 95% CI, 1.03, 1.41), was inferior to enoxaparin. The incidence of proximal DVT favored apixaban (RR, 0.45; 95% CI, 0.27, 0.75) only. Rivaroxaban (RR, 0.45; 95% CI, 0.27, 0,77) and apixaban (RR, 0.38; 95% CI, 0.16, 0.90) produced significantly lower frequencies of symptomatic DVT. The incidence of major VTE favored rivaroxaban (RR, 0.44; 95% CI, 0.25, 0.81), only. Bleeding risk was similar for all NACs, except fondaparinux (RR, 1.27; 95% CI, 1.04, 1.55), which exhibited a significantly higher any-bleeding risk compared with enoxaparin, and apixaban (RR, 0.88; 95% CI, 0.79, 0.99), which was associated with a reduced risk of any bleeding. Alanine amino transferase was significantly lower with 220 mg of dabigatran, (RR, 0.67; 95% CI, 0.79, 0.99) than with enoxaparin. Conclusions: NACs can be considered alternatives to conventional thromboprophylaxis regimens in patients undergoing elective major orthopedic surgery, depending on clinical characteristics and cost-effectiveness. The knowledge of some differences concerning efficacy or safety profile, pointed out in this systematic review, along with the respective limitations, may be useful in clinical practice. © 2013 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the measurement of the concentration and size of particles and the identification of their sources were carried out at five orthopedic surgeries. The aerosol concentration and particle size distribution, ranging from 0.3 mu m 10 mu m, were measured and related to the type of indoor activity. The handling of surgical linen and gowns, handling of the patient, use of electrosurgical apparatus, use of a bone saw, handling of equipment, and cleaning of the room were identified as the most important sources of particles, with each of these activities posing different risks to the health of the patients and workers. The results showed that most of the particles were above 0.5 mu m and that there was a strong correlation among all particles of sizes above 1 mu m. Particles with diameters in the range of 0.3 mu m-0.5 mu m had a good correlation only with particles in the ranges of 0.5 mu m-1.0 mu m and 1.0 mu m-3.0 mu m in three of the surgeries analyzed. Findings led to the conclusion that most of the events responsible for generating aerosol particles in an orthopedic surgery room are brief, intermittent, and highly variable, thus requiring the use of specific instrumentation for their continuous identification and characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several adverse consequences are caused by mild perioperative hypothermia. Maintaining normothermia with patient warming systems, today mostly with forced air (FA), has thus become a standard procedure during anesthesia. Recently, a polymer-based resistive patient warming system was developed. We compared the efficacy of a widely distributed FA system with the resistive-polymer (RP) system in a prospective, randomized clinical study. METHODS: Eighty patients scheduled for orthopedic surgery were randomized to either FA warming (Bair Hugger warming blanket #522 and blower #750, Arizant, Eden Prairie, MN) or RP warming (Hot Dog Multi-Position Blanket and Hot Dog controller, Augustine Biomedical, Eden Prairie, MN). Core temperature, skin temperature (head, upper and lower arm, chest, abdomen, back, thigh, and calf), and room temperature (general and near the patient) were recorded continuously. RESULTS: After an initial decrease, core temperatures increased in both groups at comparable rates (FA: 0.33 degrees C/h +/- 0.34 degrees C/h; RP: 0.29 degrees C/h +/- 0.35 degrees C/h; P = 0.6). There was also no difference in the course of mean skin and mean body (core) temperature. FA warming increased the environment close to the patient (the workplace of anesthesiologists and surgeons) more than RP warming (24.4 degrees C +/- 5.2 degrees C for FA vs 22.6 degrees C +/- 1.9 degrees C for RP at 30 minutes; P(AUC) <0.01). CONCLUSION: RP warming performed as efficiently as FA warming in patients undergoing orthopedic surgery.