980 resultados para lens thickness


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the ocular refractive and biometric characteristics in patients with tilted disc syndrome (TDS). Methods: This case-control study comprised 41 eyes of 25 patients with established TDS and forty eyes of 20 age- and sex-matched healthy control subjects. All had a complete ocular examination including refraction and analysis using Fourier transformation, slit lamp biomicroscopy, pachymetry keratometry, and ocular biometry. Corneal topography examinations were performed in the syndrome group only. Results: There were no significant differences in spherical equivalent (p = 0.334) and total astigmatism (p= 0.246) between groups. However, mean best spectacular corrected visual acuity was significantly worse in TDS patients (P < 0.001). The lenticular astigmatism was significantly greater in the syndrome group, while the corneal component was greater in the controls (p = 0.004 and p = 0.002, respectively). The measured biometric features were the same in both groups, except for the lens thickness, relative lens position, and lens-axial length factor which were greater in the TDS group (p = 0.002, p = 0.015, and p = 0.025, respectively). Conclusions: Clinically significant lenticular astigmatism, more oblique corneal astigmatism, and thicker lens were characteristic findings in patients with TDS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This is a comprehensive study of a large range of biometric and optical parameters in people with type 1 diabetes. The parameters of 74 people with type 1 diabetes and an age matched control group were assessed. Most of the people with diabetes had low levels of neuropathy, retinopathy and nephropathy. Marginal or no significant differences were found between groups for corneal shape, corneal thickness, pupil size, and pupil decentrations. Relative to the control group, the diabetes group demonstrated smaller anterior chamber depths, more curved lenses, greater lens thickness and lower lens equivalent refractive index. While the optics of diabetic eyes make them appear as older eyes than those of people of the same age without diabetes, the differences did not increase significantly with age. Age-related changes in the optics of the eyes of people with diabetes need not be accelerated if the diabetes is well controlled.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To describe distributions of ocular biometry and their associations with refraction in 7- and 14-year-old children in urban areas of Anyang, central China. Methods: A total of 2271 grade 1 students aged 7.1 ± 0.4 years and 1786 grade 8 students aged 13.7 ± 0.5 years were measured with ocular biometry and cycloplegic refraction. A parental myopia questionnaire was administered to parents. Results: Mean axial length, anterior chamber depth, lens thickness, central corneal thickness, corneal diameter, corneal radius of curvature, axial length/corneal radius of curvature ratio, and spherical equivalent refraction were 22.72 ± 0.76 mm, 2.89 ± 0.24 mm, 3.61 ± 0.19 mm, 540.5 ± 31 μm, 12.06 ± 0.44 mm, 7.80 ± 0.25 mm, 2.91 ± 0.08, and +0.95 ± 1.05 diopters (D), respectively, in 7-year-old children. They were 24.39 ± 1.13 mm, 3.42 ± 0.41 mm, 3.18 ± 0.24 mm, 548.9 ± 33 μm, 12.03 ± 0.43 mm, 7.80 ± 0.26 mm, 3.13 ± 0.14, and −2.06 ± 2.20 D, respectively, in 14-year-old children. Compared with 7-year-old children, the older group had significantly more myopia (−3.0 D), longer axial length (1.7 mm), deeper anterior chamber depth (0.3 mm), thinner lens thickness (−0.2 mm), thicker central corneal thickness (10 μm), and greater axial length/corneal radius of curvature ratio (0.22) (all p < 0.001), as well as smaller corneal diameter (−0.03 mm, p = 0.02) and similar corneal radius of curvature. Sex differences were similar in both age groups, with boys having longer axial length (0.5 mm), deeper anterior chamber depth (0.1 mm), shorter lens thickness (0.03 mm), greater central corneal thickness (5 μm), greater corneal diameter (0.15 mm), and greater corneal radius of curvature (0.14 mm) than girls (all p < 0.01). The most important variables related to spherical equivalent refraction were vitreous length, corneal radius of curvature, and lens thickness. Conclusions: The 14-year-old group had larger parameter dimensions than the 7-year-old group except for corneal radius of curvature (unchanged) and lens thickness and corneal diameter (both smaller). Boys had large parameter dimensions than girls except for lens thickness (smaller). Axial length, corneal radius of curvature, and lens thickness were the most important determinants of refraction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose.: To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. Methods.: Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. Results.: A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 ± 0.4 and 13.7 ± 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. Conclusions.: The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Importance: This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons.

Objective: To study cohort effects and changes associated with aging in REs among Chinese adults.

Design, Setting, and Participants: A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery.

Methods: Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed.

Main Outcomes and Measures: Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye.

Results: A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from −0.44 (2.21) to −0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at −0.06 mm/y (95% CI, −0.09 to −0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons.

Conclusions and Relevance: This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND:

The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency.

METHODS:

A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161-7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects.

RESULTS:

Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond.

CONCLUSIONS:

Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conhecer o aspecto e as dimensões de olhos de cabras facilita o uso da ultrassonografia na avaliação de doenças oculares. O objetivo do presente trabalho foi o de avaliar os achados ultrassonográficos e ecobiométricos em olhos de cabras adultas. Ultrassonogramas nos modos A e B foram realizados em 30 caprinos adultos (60 olhos) (n=15 fêmeas intactas e n=15 machos castrados). O exame ultrassonográfico foi realizado após a instilação de colírio anestésico. Gel a base de água foi utilizado sobre o transdutor de 20 MHz posicionado-o de forma longitudinasobre a córneal, até que imagens no modo B estivessem de acordo com os ecos gerados pelo modo A. Utilizou-se análise estatística para se comparar os achados ecobiométricos entre os sexos (p<0,05). As médias com seus respectivos desvios padrões das estruturas oculares em machos e fêmeas foram, respectivamente, 3,46±0,55, 3,33±0,46mm (profundidade da câmara anterior); 8,60±0,34, 8,65±0,39mm (espessura da lente); 11,34±0,61, 11,39±0,66mm (profundidade da câmara vítrea) e 23,43±0,92, 23,39±0.86mm (comprimento axial do bulbo ocular). Não foi observada diferença significativa entre os olhos direito e esquerdo, assim como entre machos e fêmeas (p>0,05). O aspecto ultrassonográfico de olhos de cabras se assemelha com o de outras espécies domésticas e silvestres.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to establish mean values for intraocular structures and analyse if the differences are present for different skull conformations in dogs. In this study, 30 dogs were selected and distributed into three groups according to skull conformation; thus, group 1 (G1) was composed of brachycephalic dogs, group 2 (G2) was composed of mesocephalic dogs and group 3 (G3) was composed of dolichocephalic dogs. A and B-mode ultrasound was performed simultaneously for obtainment of measurements relating to anterior chamber depth (D1); lens thickness (D2); vitreous chamber depth (D3); and the axial length of the eye (D4). No differences were observed when comparing left and right eyes of dogs within the same skull conformation group (p>0.05). Differences were observed when comparing D3 and D4 between groups G2 and G3 (p<0.05). Skull conformation of brachycephalic dogs did not influence intraocular measurement values when compared to dolicephalic and mesocephalic dogs. Skull conformation of dolichocephalic dogs had an influence in values of vitreous chamber and the complete length of the eye when compared to mesocephalic dogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliou-se 31 cães saudáveis, sem raça definida, sendo 10 machos e 21 fêmeas, com 8 meses a 7 anos de idade e peso de1,5-28 kg. Inicialmente foram mensurados os diâmetros fronto-occiptal (DFO) e bizigomático (DBZ) do crânio com o auxílio de um paquímetro. A ultra-sonografia transpalpebral em modo-B foi realizada para mensurar as estruturas do bulbo ocular, conforme se segue: D1- espessura da córnea; D2- distância entre o ponto central da imagem da córnea e a da cápsula anterior do cristalino (câmara anterior); D3- distância entre o ponto central da imagem da córnea e a da cápsula posterior do cristalino; D4- espessura do cristalino, que corresponde a distância entre a imagem da cápsula anterior e a cápsula posterior do cristalino; D5- diâmetro do cristalino, distância entre as imagens dos pólos do cristalino; D6– área do cristalino; D7- câmara vítrea, distância entre a imagem da cápsula posterior do cristalino e a retina; D8- distância entre a cápsula anterior do cristalino e a retina; D9- distância entre a imagem da córnea e a retina. Com exceção da D4, houve efeito dos DFO e DBZ sobre as medidas das estruturas internas do BO. A análise de regressão linear entre as medidas das estruturas do bulbo ocular e os DFO e DBZ foram significativas para D1, D2, D3, D4, D5, D6, D7, D8 e D9.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV