994 resultados para force sensor


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper describes a strain gauge-based sensor used for measuring finger force. The theory, design, and sensor construction details are presented. It was constructed using metallic strain gauges and a carefully designed structure which has a protection de-vice that impedes the sensor damage when forces higher than 100 N are applied. Its dimensions are suitable for measuring thumb force, but the same design can be used for constructing smaller sensors for other fingers. It is rugged, presents linear response, good repeatability, resolution of 0.3 N, low hysteresis, and sensitivity of 0.12 V/N. It can be useful in rehabilitation engineering, biomechanics, robotics, and medicine.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Haptically enabled virtual reality systems facilitate rapid and low cost testing for process design, training practices and ergonomic analysis in many manufacturing industries, particularly automotive and aerospace. In this work we design a validation framework to validate the dynamic forces displayed by haptic display devices using a robot arm equipped with a force sensor. The validation framework is completely autonomous to ensure unbiased characterization. Measured force magnitude and the direction of the sensed force vector are the main criteria used in this work.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of the work described in this dissertation is the development of new wireless passive force monitoring platforms for applications in the medical field, specifically monitoring lower limb prosthetics. The developed sensors consist of stress sensitive, magnetically soft amorphous metallic glass materials. The first technology is based on magnetoelastic resonance. Specifically, when exposed to an AC excitation field along with a constant DC bias field, the magnetoelastic material mechanically vibrates, and may reaches resonance if the field frequency matches the mechanical resonant frequency of the material. The presented work illustrates that an applied loading pins portions of the strip, effectively decreasing the strip length, which results in an increase in the frequency of the resonance. The developed technology is deployed in a prototype lower limb prosthetic sleeve for monitoring forces experienced by the distal end of the residuum. This work also reports on the development of a magnetoharmonic force sensor comprised of the same material. According to the Villari effect, an applied loading to the material results in a change in the permeability of the magnetic sensor which is visualized as an increase in the higher-order harmonic fields of the material. Specifically, by applying a constant low frequency AC field and sweeping the applied DC biasing field, the higher-order harmonic components of the magnetic response can be visualized. This sensor technology was also instrumented onto a lower limb prosthetic for proof of deployment; however, the magnetoharmonic sensor illustrated complications with sensor positioning and a necessity to tailor the interface mechanics between the sensing material and the surface being monitored. The novelty of these two technologies is in their wireless passive nature which allows for long term monitoring over the life time of a given device. Additionally, the developed technologies are low cost. Recommendations for future works include improving the system for real-time monitoring, useful for data collection outside of a clinical setting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by 4 fold anteriorly and 14 fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by 9 fold laterally and 16 fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17 % and 83 % of the trials, respectively, by up to ±10 %. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a real-time haptics-aided injection technique for biological cells using miniature compliant mechanisms. Our system consists of a haptic robot operated by a human hand, an XYZ stage for micro-positioning, a camera for image capture, and a polydimethylsiloxane (PDMS) miniature compliant device that serves the dual purpose of an injecting tool and a force-sensor. In contrast to existing haptics-based micromanipulation techniques where an external force sensor is used, we use visually captured displacements of the compliant mechanism to compute the applied and reaction forces. The human hand can feel the magnified manipulation force through the haptic device in real-time while the motion of the human hand is replicated on the mechanism side. The images are captured using a camera at the rate of 30 frames per second for extracting the displacement data. This is used to compute the forces at the rate of 30 Hz. The force computed in this manner is sent at the rate of 1000 Hz to ensure stable haptic interaction. The haptic cell-manipulation system was tested by injecting into a zebrafish egg cell after validating the technique at a size larger than that of the cell.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measuring forces applied by multi-cellular organisms is valuable in investigating biomechanics of their locomotion. Several technologies have been developed to measure such forces, for example, strain gauges, micro-machined sensors, and calibrated cantilevers. We introduce an innovative combination of techniques as a high throughput screening tool to assess forces applied by multiple genetic model organisms. First, we fabricated colored Polydimethylsiloxane (PDMS) micropillars where the color enhances contrast making it easier to detect and track pillar displacement driven by the organism. Second, we developed a semiautomated graphical user interface to analyze the images for pillar displacement, thus reducing the analysis time for each animal to minutes. The addition of color reduced the Young's modulus of PDMS. Therefore, the dye-PDMS composite was characterized using Yeoh's hyperelastic model and the pillars were calibrated using a silicon based force sensor. We used our device to measure forces exerted by wild type and mutant Caenorhabditis elegans moving on an agarose surface. Wild type C. elegans exert an average force of similar to 1 mu N on an individual pillar and a total average force of similar to 7.68 mu N. We show that the middle of C. elegans exerts more force than its extremities. We find that C. elegans mutants with defective body wall muscles apply significantly lower force on individual pillars, while mutants defective in sensing externally applied mechanical forces still apply the same average force per pillar compared to wild type animals. Average forces applied per pillar are independent of the length, diameter, or cuticle stiffness of the animal. We also used the device to measure, for the first time, forces applied by Drosophila melanogaster larvae. Peristaltic waves occurred at 0.4Hz applying an average force of similar to 1.58 mu N on a single pillar. Our colored microfluidic device along with its displacement tracking software allows us to measure forces applied by multiple model organisms that crawl or slither to travel through their environment. (C) 2015 AIP Publishing LLC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract. A low power arcjet-thruster of 1 kW-class with gas mixture of H2-N2 or pure argon as the propellant is fired at a chamber pressure about 10 Pa. The nozzle temperature is detected with an infrared pyrometer; a plate set perpendicular to the plume axis and connected to a force sensor is used to measure the thrust; a probe with a tapered head is used for measuring the impact pressure in the plume flow; and a double-electrostatic probe system is applied to evaluate the electron temperature. Results indicate that the high nozzle temperature could adversely affect the conversion from enthalpy to kinetic energy. The plume flow deviates evidently from the LTE condition, and the rarefied-gas dynamic effect should be considered under the high temperature and low-pressure condition in analyzing the experimental phenomena.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[EU]Dokumentu honek "Panpinan Egindako Bihotz-Biriketako Berpizte Maniobran Bularra Bere Onera Bueltatzearen Analisia" izena duen Gradu Amaierako Lanaren memoria eta eranskinak biltzen ditu. Bertan, lan horren bitartez lorturiko helburuak, horiek nola lortu diren eta burutu ahal izateko egin beharreko pausuak aurkezten dira. Bihotz-biriketako berpizterako berrelikadura gailuek berpizte maniobren kalitateari buruzko informazioa momentuan ematen dute. Proiektua berrelikadurarako laguntza gailuen parametroen kalitatea hobetzeko ikerlan bat egitera bideratuta dago, zehazki bularra bere onera bueltatzen den jakiteko metodoen azterketan sakontzen duelarik interesa duelarik. Alde batetik, benetako sakoneraren kalkulu zehatzari buruzko ikerketa bat egiten da, horretarako aukera ezberdinak aztertuz, metodo desberdinen analisia eginez. Bestetik, berrelikaduran zehar bularra bere onera bueltatzen den ohartarazteko (esate baterako, alarma sistema baten bitartez) parametroan egiten da ikerketa, horretarako indar sentsore gehigarri bat erabiliz.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Light has long been used for the precise measurement of moving bodies, but the burgeoning field of optomechanics is concerned with the interaction of light and matter in a regime where the typically weak radiation pressure force of light is able to push back on the moving object. This field began with the realization in the late 1960's that the momentum imparted by a recoiling photon on a mirror would place fundamental limits on the smallest measurable displacement of that mirror. This coupling between the frequency of light and the motion of a mechanical object does much more than simply add noise, however. It has been used to cool objects to their quantum ground state, demonstrate electromagnetically-induced-transparency, and modify the damping and spring constant of the resonator. Amazingly, these radiation pressure effects have now been demonstrated in systems ranging 18 orders of magnitude in mass (kg to fg).

In this work we will focus on three diverse experiments in three different optomechanical devices which span the fields of inertial sensors, closed-loop feedback, and nonlinear dynamics. The mechanical elements presented cover 6 orders of magnitude in mass (ng to fg), but they all employ nano-scale photonic crystals to trap light and resonantly enhance the light-matter interaction. In the first experiment we take advantage of the sub-femtometer displacement resolution of our photonic crystals to demonstrate a sensitive chip-scale optical accelerometer with a kHz-frequency mechanical resonator. This sensor has a noise density of approximately 10 micro-g/rt-Hz over a useable bandwidth of approximately 20 kHz and we demonstrate at least 50 dB of linear dynamic sensor range. We also discuss methods to further improve performance of this device by a factor of 10.

In the second experiment, we used a closed-loop measurement and feedback system to damp and cool a room-temperature MHz-frequency mechanical oscillator from a phonon occupation of 6.5 million down to just 66. At the time of the experiment, this represented a world-record result for the laser cooling of a macroscopic mechanical element without the aid of cryogenic pre-cooling. Furthermore, this closed-loop damping yields a high-resolution force sensor with a practical bandwidth of 200 kHZ and the method has applications to other optomechanical sensors.

The final experiment contains results from a GHz-frequency mechanical resonator in a regime where the nonlinearity of the radiation-pressure interaction dominates the system dynamics. In this device we show self-oscillations of the mechanical element that are driven by multi-photon-phonon scattering. Control of the system allows us to initialize the mechanical oscillator into a stable high-amplitude attractor which would otherwise be inaccessible. To provide context, we begin this work by first presenting an intuitive overview of optomechanical systems and then providing an extended discussion of the principles underlying the design and fabrication of our optomechanical devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effect of strain rate upon the uniaxial response of Ultra High Molecular-weight Polyethylene (UHMWPE) fibres, yarns and laminates of lay-up [0/90]48 has been measured in both the 0/90 and ±45 configurations. The tensile strength of the matrix-dominated ±45 laminate is two orders of magnitude less than that of the fibre-dominated 0/90 laminate, and is more sensitive to strain rate. A piezoelectric force sensor device was developed to obtain the high strain rate data, and this achieved a rise time of less than 1 μs. It is found that the failure strength (and failure strain) of the yarn is almost insensitive to strain rate within the range (10 -1-103 s-1). At low strain rates (below 10 -1 s-1), creep of the yarn dominates and the failure strain increases with diminishing strain rate. The tensile strength of the dry yarn exceeds that of the laminate by about 20%. Tests on single fibres exceed the strength of the yarn by 20%. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is widely acknowledged that ceramic armor experiences an unsteady penetration response: an impacting projectile may erode on the surface of a ceramic target without substantial penetration for a significant amount of time and then suddenly start to penetrate the target. Although known for more than four decades, this phenomenon, commonly referred to as dwell, remains largely unexplained. Here, we use scaled analog experiments with a low-speed water jet and a soft, translucent target material to investigate dwell. The transient target response, in terms of depth of penetration and impact force, is captured using a high-speed camera in combination with a piezoelectric force sensor. We observe the phenomenon of dwell using a soft (noncracking) target material. The results show that the penetration rate increases when the flow of the impacting water jet is reversed due to the deformation of the jet-target interface--this reversal is also associated with an increase in the force exerted by the jet on the target. Creep penetration experiments with a constant indentation force did not show an increase in the penetration rate, confirming that flow reversal is the cause of the unsteady penetration rate. Our results suggest that dwell can occur in a ductile noncracking target due to flow reversal. This phenomenon of flow reversal is rather widespread and present in a wide range of impact situations, including water-jet cutting, needleless injection, and deposit removal via a fluid jet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

在对机器人腕力传感器信号特点分析基础上,提出了应用小波变换对腕力传感器信号进行滤波的方法,讨论了小波滤波算法,研究了机器人腕力传感器信号滤波方案,并针对抛光机器人作业实验数据进行滤波。仿真实验表明方法有效。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

研磨机器人系统中,研磨头与工件的接触力是保证加工精度,进行机器人力控制的一个重要因 素。采用 CAN 通讯可以确保力传感器准确、及时地把力信息传送给控制器进行力控制。本文 给出了6维腕力传感器与机器人控制器通讯的硬件结构,制定了可靠的通讯协议,实现了力信 息的正确读取,为研磨机器人控制系统获得可靠的力信息提供了一种新的解决方案。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文设计了一种新颖的微力感知传感器及其标定方法,以获得亚μN(micro Newton)的可靠的、高精度力反馈信息。可靠的、高精度的微力感知和控制在提高微装配的效率上具有重要的作用。目前微装配中还没有可靠的亚μN分辨率的传感器。本文以PVDF(polyvinylidene fluoride)为基本材料,建立出PVDF传感器所受的微力与输出电压之间的关系模型,开发出相应的信号处理电路,并对PVDF传感器的上述模型进行了标定。实验结果表明本文开发的PVDF传感器具有亚μN的分辨率,同时验证了本文建立的PVDF传感器模型的正确性,并证明了信号处理电路以及标定方法是有效的。本文设计的微力传感器为微装配和微操作中微接触力的反馈控制提供了可靠的解决方法,并将促进微装配和微操作的自动化加工技术水平,实现微型装备的可靠、高产量的批量制造。