984 resultados para Sewage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbiological quality of the treated wastewater is an important parameter for its reuse. The data oil the Fecal Coliform (FC) and Fecal Streptococcus (FS) at different stages of treatment in the Sewage Treatment Plants (STPs) in Delhi watershed is not available, therefore in the present study microbial profiling of STPs was carried out to assess the effluent quality for present and future reuse options. This Study further evaluates the water quality profiles at different stages of treatment for 16 STPs in Delhi city. These STPs are based on conventional Activated Sludge Process (ASP), extended aeration, physical, chemical and biological treatment (BIOFORE), Trickling Filter and Oxidation Pond. The primary effluent quality produced from most of the STPs was suitable for Soil Aquifer Treatment (SAT). Extended Hydraulic Retention Time (HRT) as a result Of low inflow to the STPS Was responsible for high turbidity, COD and BODs removal. Conventional ASP based STPs achieved 1.66 log FC and 1.06 log FS removal. STPs with extended aeration treatment process produced better quality effluent with maximum 4 log order reduction in FC and FS levels. ``Kondli'' and ``Nilothi'' STPs employing ASP, produced better quality secondary effluent as compared to other STPs based oil similar treatment process. Oxidation Pond based STPs showed better FC and FS removals, whereas good physiochemical quality was achieved during the first half of the treatment. Based upon physical, chemical and microbiological removal efficiencies, actual integrated efficiency (IEa) of each STP was determined to evaluate its Suitability for reuse for irrigation purposes. Except Mehrauli'' and ``Oxidation Pond'', effluents from all other STPs require tertiary treatment for further reuse. Possible reuse options, depending Upon the geographical location, proximity of facilities of potential users based oil the beneficial uses, and sub-soil types, etc. for the Delhi city have been investigated, which include artificial groundwater recharge, aquaculture, horticulture and industrial uses Such as floor washing, boiler feed, and cooling towers, etc. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STOAT has been extensively used for the dynamic simulation of an activated sludge based wastewater treatment plant in the Titagarh Sewage Treatment Plant, near Kolkata, India. Some alternative schemes were suggested. Different schemes were compared for the removal of Total Suspended Solids (TSS), b-COD, ammonia, nitrates etc. A combination of IAWQ#1 module with the Takacs module gave best results for the existing scenarios of the Titagarh Sewage Treatment Plant. The modified Bardenpho process was found most effective for reducing the mean b-COD level to as low as 31.4 mg/l, while the mean TSS level was as high as 100.98 mg/l as compared to the mean levels of TSS (92 62 mg/l) and b-COD (92.0 mg/l) in the existing plant. Scheme 2 gave a better scenario for the mean TSS level bringing it down to a mean value of 0.4 mg/l, but a higher mean value for the b-COD level at 54.89 mg/l. The Scheme Final could reduce the mean TSS level to 2.9 mg/l and the mean b-COD level to as low as 38.8 mg/l. The Final Scheme looks to be a technically viable scheme with respect to the overall effluent quality for the plant. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vuorokausivirtaaman ennustaminen yhdyskuntien vesi- ja viemärilaitosten yleissuunnittelussa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C:N ratio of lake sediments provide valuable information about the source and proportions of terrestrial, phytogenic and phycogenic carbon and nitrogen. This study has been carried out in Varthur lake which is receiving sewage since many decades apart from large scale land cover changes. C:N profile of the surficial sediment layer collected in the rainy and the dry seasons revealed higher C:N values[43] due to the accumulation of autochthonous organic material mostly at the deeper portions of the lake. This also highlights N limitation in the sludge either due to uptake by micro and macro-biota or rapid volatilization, denitrification and possible leaching in water. Organic Carbon was lower towards the inlets and higher near the deeper zones. This pattern of Organic C deposition was aided by gusty winds and high flow conditions together with impacts by the land use land cover changes in the watershed. Spatial variability of C:N in surficial sediments is significant compared to its seasonal variability. This communication provides an insight to the pattern in which nutrients are distributed in the sludge/sediment and its variation across seasons and space impacted by the biotic process accompanied by the hydrodynamic changes in the lake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urban water bodies frequently receive untreated sewage and water levels in such water bodies are maintained by daily inputs of sewage. They function as “variable-zone” anaerobic-aerobic lagoons suffering several macrophyte, biotic and abiotic stresses. We have studied two such lakes in Bangalore (Bellandur-360 ha and Varthur-220 ha) to understand whether such an occurrence could be made beneficial (maintaining water levels as well as treatment). Such hypertrophic water body receives sewage at 180-250mg/L and is discharged at 25-80mg/L COD/BOD in different seasons. In an earlier study we reported macrophyte altering the purification function of the water body. In this paper we studied the impact of phytoplankton dynamics and macrophyte cover on the functions such as organic load removal. Algal community analysis, algal biomass, macrophyte cover, water quality, nutrient status was studied seasonally during 2009-2010. Oxygen deficiency and sometimes anoxia, recorded from surface samples resulted in high quantities of NH4+-N (30-40mg/L) and phosphate (0.5-4mg/L)-characteristics of anoxic hypertrophic urban lakes. The productiveness favoured high phytoplanktonic community characterized by small cells (<10μm; Chlorella sp. - highest numbers). The lake could be clearly demarcated into an initial anaerobic zone (40% area), a facultative zone (20%) and an aerobic zone (40%) based on redox values and GIS/bathymetry. During summer the lake is covered by floating macrophytes converting the lake into an anoxic/anaerobic water pool subduing the water purification function as well as aesthetics. When macrophytes are controlled such sewage fed water bodies can be used for treating urban wastewater while also maintaining water sustainability in these semi-arid ecosystems. This paper reports the community dynamics of phytoplankton, their function and competition with macrophytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lagoons have been traditionally used in India for decentralized treatment of domestic sewage. These are cost effective as they depend mainly on natural processes without any external energy inputs. This study focuses on the treatment efficiency of algae-based sewage treatment plant (STP) of 67.65 million liters per day (MLD) capacity considering the characteristics of domestic wastewater (sewage) and functioning of the treatment plant, while attempting to understand the role of algae in the treatment. STP performance was assessed by diurnal as well as periodic investigations of key water quality parameters and algal biota. STP with a residence time of 14.3 days perform moderately, which is evident from the removal of total chemical oxygen demand (COD) (60 %), filterable COD (50 %), total biochemical oxygen demand (BOD) (82 %), and filterable BOD (70 %) as sewage travels from the inlet to the outlet. Furthermore, nitrogen content showed sharp variations with total Kjeldahl nitrogen (TKN) removal of 36 %; ammonium N (NH4-N) removal efficiency of 18 %, nitrate (NO3-N) removal efficiency of 22 %, and nitrite (NO2-N) removal efficiency of 57.8 %. The predominant algae are euglenoides (in facultative lagoons) and chlorophycean members (maturation ponds). The drastic decrease of particulates and suspended matter highlights heterotrophy of euglenoides in removing particulates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study owes its inception to the wisdom and experience of the staff of the Northeast Fisheries Science Center who, after several decades of surveys in the New York Bight, recognized a unique opportunity to capitalize on the decision to stop ocean dumping of sewage sludge and designed an innovative field study to evaluate effects on living marine resources and their habitats. For decades ocean dumping was viewed as a cheap and effective means for disposal of wastes generated by urbanized coastal areas. Even after the 12-mile site was closed, sewage sludge continued to be dumped at Deepwater Dumpsite 106. The 6-mile site off the NewJersey coast is still used as a dumpsite for dredged material from New York Harbor areas. Discussions continue on the propriety of using the deep ocean spaces for disposal of a variety of material including low level radioactive wastes. Consequently, managers are still faced with critical decisions in this area. It is to be hoped that the results from the 12-mile study will provide the necessary information on which these managers can evaluate future risks associated with ocean waste disposal. (PDF file contains 270 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The utilization of waste waters in aquaculture were briefly reviewed. At the National Institute for Freshwater Fisheries Research (NIFFR), stocking density (20 to 160 fish/m super(3)) experiments using Sarotherodon galilaeus (without supplementary feeding) in floating cages were carried out in a sewage pond (0.4ha surface area). Cage culture of S. galilaeus was observed to have potentials in waste waters aquaculture. Recommendations were made on the execution of an intergrated waste water management and utilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The studies reported were undertaken as part of a wide environmental feasibility study for the establishment of a modern sewage system in Freetown. The aim of this part of the study was to determine whether the hydrological regime of the Sierra Leone River Estuary would permit the large-scale introduction of sewage into the estuary without damaging the environment. The important factors were whether: 1) there would be sufficient dilution of the sewage; 2) fleatable particles or other substances would create significant adverse effects in the estuarine ecosystem. The outfall sites are described together with the sampling stations, methods and analyses. Results include: 1) T/S profiles; 2) chemical analysis of the water. A review of literature on the Sierra Leone River Estuary is included which provides information on the plankton, benthos and fisheries. Results suggest that at certain points where local circulations occur it would be inadvisable to locate untreated sewage outfalls. Such points are frequently observed in small embayments. These studies have been of short duration but the data can serve as baseline for more extended investigations which would give a more complete picture of the seasonal patterns in the estuary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No abstract.