988 resultados para Roof-harvested rainwater


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The rapid and ongoing expansion of urbanised impervious areas could lead to more frequent flood inundation in urban flood-prone regions. Nowadays, urban flood inundation induced by rainstorm is an expensive natural disaster in many countries. In order to reduce the flooding risk, eco-roof systems (or green roof systems) could be considered as an effective mechanism of mitigating flooding disasters through their rainwater retention capability. However, there is still a lack of examining the stormwater management tool. The purpose of this paper is to evaluate the effects on flooding disaster from extensive green roofs. Design/methodology/approach: Based on geographical information system (GIS) simulation, this research presents a frame of assessing eco-roof impacts on urban flash floods. The approach addresses both urban rainfall-runoff and underground hydrologic models for traditional impervious and green roofs. Deakin University’s Geelong Waurn Ponds campus is chosen as a study case. GIS technologies are then utilised to visualise and analyse the effects on flood inundation from surface properties of building roofs. Findings: The results reveal that the eco-roof systems generate varying degrees of mitigation of urban flood inundation with different return period storms. Originality/value: Although the eco-roof technology is considered as an effective stormwater management tool, it is not commonly adopted and examined in urban floods. This study will bring benefits to urban planners for raising awareness of hazard impacts and to construction technicians for considering disaster mitigation via roof technologies. The approach proposed here could be used for the disaster mitigation in future urban planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It lies 27°S of the Equator, wrapped uneasily around a wide, muddy river. Three years ago, Brisbane was identified by Billboard Magazine as one of six “hot spots” of independent music in the world. A place to watch. Someone turned a torch on this town, had a quick look, moved on. But this town has always had music in it. Some of it made by me. So, I’m taking my connection with this town, the music and the people, and working it into a contextual historical analysis of the creative lives of Brisbane musicians, and by extension, of Brisbane’s music and Brisbane itself. Talking about what music means to us, how it figures in our lives, and considering the notion, among other factors, of ‘place’ in both our creative practice and creative output. This paper offers an analysis of a particular auto/ethnographic method. How lives are organized and intensified by sounds made and heard in particular social and geographic settings. How music can be the thread which, when pulled, unravels stories, reveals certain truths about musicians and their relationships to one another, to family, to place and to their work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, numerical simulations of natural convection in an attic space subject to diurnal temperature condition on the sloping wall have been carried out. An explanation of choosing the period of periodic thermal effect has been given with help of the scaling analysis which is available in the literature. Moreover, the effects of the aspect ratio and Rayleigh number on the fluid flow and heat transfer have been discussed in details as well as the formation of a pitchfork bifurcation of the flow at the symmetric line of the enclosure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates cooling energy performance of commercial building before and after green roof and living wall application based on integrated building heat gain model developed from Overall Thermal Transfer Value (OTTV) of building wall and steady state heat transfer process of roof in sub-tropical climate. Using the modelled equation and eQUEST energy simulation tool, commercial building envelope parameters and relevant heat gain parameters have been accumulated to analyse the heat gain and cooling energy consumption of commercial building. Real life commercial building envelope and air-conditioned load data for the sub-tropical climate zone have been collected and compared with the modelled analysis. Relevant temperature data required for living wall and green roof analysis have been collected from experimental setup comprised of both green roof and west facing living wall. Then, Commercial building heat flux and cooling energy performance before and after green roof and living wall application have been scrutinized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pollutant impacts of urban stormwater runoff on receiving waters are well documented in research literature. However, it is road surfaces that are commonly identified as the significant pollutant source. This paper presents the outcomes of an extensive program of research into the role of roof surfaces in urban water quality with particular focus on solids, nutrients and organic carbon. The outcomes confirmed that roof surfaces play an important role in influencing the pollutant characteristics of urban stormwater runoff. Pollutant build-up and wash-off characteristics for roads and roof surfaces were found to be appreciably different. The pollutant wash-off characteristics exhibited by roof surfaces show that it influences the first flush phenomenon more significantly than road surfaces. In most urban catchments, as roof surfaces constitutes a higher fraction of impervious area compared to road surfaces, it is important that the pollutant generation role of roof surfaces is specifically taken into consideration in stormwater quality mitigation strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research examined why university campus development has not fully embraced green technology despite common expectations. Semi-structured interviews and a Delphi Study explored universities’ organisational issues and delivery processes for projects with a sustainability focus. Critical organisational components and their internal relationships were studied, and critical factors for project success identified. A decision-making framework was developed to provide strategic directions for universities to optimise organisational environment and overcome barriers in order to better deliver sustainable projects on campuses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of an analytical model used to simulate the fatigue behaviour of roof cladding during the passage of a tropical cyclone. The model incorporated into a computer program uses wind pressure data from wind tunnel tests in combination with time history information on wind speed and direction during a tropical cyclone, and experimental fatigue characteristics data of roof claddings. The wind pressure data is analysed using a rainflow form of analysis, and a fatigue damage index calculated using a modified form of Miner's rule. Some of the results obtained to date and their significance in relation to the review of current fatigue tests are presented. The model appears to be reasonable for comparative estimation of fatigue life, but an improvement of Miner's rule is required for the prediction of actual fatigue life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Profiled steel roof claddings in Australia are commonly made of very thin high tensile steel and are crest-fixed with screw fasteners. At present the design of these claddings is entirely based on testing. In order to improve the understanding of the behaviour of these claddings under wind uplift, and thus the design methods, a detailed investigation consisting of a finite element analysis and laboratory experiments was carried out on two-span roofing assemblies of three common roofing profiles. It was found that the failure of the roof cladding system was due to a local failure (dimpling of crests/pull-through) at the fasteners. This paper presents the details of the investigation, the results and then proposes a design method based on the strength of the screwed connections, for which testing of small-scale roofing models and/or using a simple design formula is recommended.