922 resultados para Resonancia Magnética
Resumo:
Arterial stiffness assessed by carotid-femoral pulse wave velocity (cfPWV) measurement is now well accepted as an independent predictor of vascular mortality and morbidity. However, the value of cfPWV has been considered to be limited for risk classification in patients with several vascular risk factors. Magnetic resonance (MR) allows measurement of PWV between two points, though to date mainly used to study the aorta. To assess the common carotid artery pulse wave velocity by magnetic resonance, determine their association with classical vascular risk factors and ischemic brain injury burden in patients with suspected ischemic cerebrovascular disease
Resumo:
[ES] En el deporte, la mayoría de las lesiones son de origen muscular y tendinoso, y aunque no son las más graves, son las más limitantes para la práctica deportiva por el número de días de incapacidad que provocan. En los deportistas profesionales, debido a las numerosas implicaciones sociales y económicas que existen, es importante pronosticar con exactitud el período de convalecencia. En la realización del diagnóstico y en el manejo terapeútico existen numerosos profesionales implicados, y el radiólogo como médico consultor se convierte en una pieza clave. Los dos métodos principales de diagnóstico son en la actualidad la ecografía y la resonancia magnética.
Resumo:
[ES] La Resonancia Magnética de la Columna Lumbar previa, y tras la administración de Gadolinio, se propone como prueba diagnóstica de primera elección de los pacientes intervenidos por hernia discal que presentan recaída de la sintomatología.
Resumo:
Ponente perteneciente al grupo de divulgación científica The Big Van Theory
Resumo:
[ES]La aplicación de la espectroscopía de resonancia magnética nuclear de protón (1H-NMR) a medios acuosos se hizo posible mediante un aparato AMX 300 MHz (Bruker) a través de un programa de pulsos incluido en el propio software que controla al espectrómetro. Dado que la secuencia de pulsos habitual (PROTON) produce una señal intensa a δ 4.67 debida a la propia agua, se utilizó un programa de pulsos (protonh2o) que la elimina por completo por irradiación a una potencia hl2 de 60 dB. Esto permitió ver y medir las señales correspondientes tanto a los hidratos de carbono como a los alcanoles.
Resumo:
Un estudio geofísico mediante resonancia se realiza mediante la excitación del agua del subsuelo a partir de la emisión de una intensidad variable a lo largo de un cable extendido sobre la superficie en forma cuadrada o circular. El volumen investigado depende del tamaño de dicho cable, lo cual, junto con la intensidad utilizada para la excitación del agua determina las diferentes profundidades del terreno de las que se va a extraer información, que se encuentran entre 10 y 100 m, habitualmente. La tesis doctoral presentada consiste en la adaptación del Método de Resonancia Magnética para su utilización en aplicaciones superficiales mediante bucles de tamaño reducido. Dicha información sobre el terreno en la escala desde decímetros a pocos metros es interesante en relación a la física de suelos y en general en relación a diferentes problemas de Ingeniería, tanto de extracción de agua como constructiva. Una vez realizada la revisión del estado de conocimiento actual del método en relación a sus aplicaciones usuales, se estudian los problemas inherentes a su adaptación a medidas superficiales. Para solventar dichos problemas se han considerado dos líneas de investigación principales: En primer lugar se realiza un estudio de la influencia de las características del pulso de excitación emitido por el equipo en la calidad de las medidas obtenidas, y las posibles estrategias para mejorar dicho pulso. El pulso de excitación es un parámetro clave en la extracción de información sobre diferentes profundidades del terreno. Por otro lado se busca la optimización del dispositivo de medida para su adaptación al estudio de los primeros metros del suelo mediante el equipo disponible, tratándose éste del equipo NumisLITE de la casa Iris Instruments. ABSTRACT Magnetic Resonance Sounding is a geophysical method performed through the excitation of the subsurface water by a variable electrical intensity delivered through a wire extended on the surface, forming a circle or a square. The investigated volume depends on the wire length and the intensity used, determining the different subsurface depths reached. In the usual application of the method, this depth ranges between 10 and 100 m. This thesis studies the adaptation of the above method to more superficial applications using smaller wire loops. Information about the subsurface in the range of decimeter to a few meters is interesting regarding physics of soils, as well as different Engineering problems, either for water extraction or for construction. After a review of the nowadays state of the art of the method regarding its usual applications, the special issues attached to its use to perform very shallow measures are studied. In order to sort out these problems two main research lines are considered: On the one hand, a study about the influence of the characteristics of the emitted pulse in the resulting measure quality is performed. Possible strategies in order to improve this pulse are investigated, as the excitation pulse is a key parameter to obtain information from different depths of the subsurface. On the other hand, the study tries to optimize the measurement device to its adaptation to the study of the first meters of the ground with the available instrumentation, the NumisLITE equipment from Iris Instruments.
Resumo:
Se presenta un algoritmo semiautomático de segmentación de aneurismas aórticos abdominales (AAA) basado en modelos activos de forma (ASM) y modelos de textura. La información de textura viene dada por un conjunto de cuatro imágenes 3D de resonancia magnética (RM) compuestas por cortes axiales de la zona abdominal. En estas imágenes son visibles la luz aórtica, la pared aórtica y el trombo intraluminal (ILT). Dado el tamaño limitado del conjunto de imágenes de RM, se han implementado un ASM que capture las características específicas del conjunto de entrenamiento compuesto por 35 imágenes de tomografía axial computarizada (CTA), de modo que la variación de forma pueda ser adecuadamente caracterizada. La textura se caracteriza a partir de las imágenes de RM. Para la evaluación del algoritmo se ha llevado a cabo una validación cruzada dejando uno fuera sobre el conjunto de imágenes de RM.
Resumo:
Objective: To show the results of a device that generates automated olfactory stimuli suitable for functional magnetic resonance imaging (fMRI) experiments. Material and methods: Te n normal volunteers, 5 women and 5 men, were studied. The system allows the programming of several sequences, providing the capability to synchronise the onset of odour presentation with acquisition by a trigger signal of the MRI scanner. The olfactometer is a device that allows selection of the odour, the event paradigm, the time of stimuli and the odour concentration. The paradigm used during fMRI scanning consisted of 15-s blocks. The odorant event took 2 s with butanol, mint and coffee. Results: We observed olfactory activity in the olfactory bulb, entorhinal cortex (4%), amygdala (2.5%) and temporo-parietal cortex, especially in the areas related to emotional integration. Conclusions: The device has demonstrated its effectiveness in stimulating olfactory areas and its capacity to adapt to fMRI equipment.RESUMEN Objetivo: Mostrar los resultados del olfatómetro capaz de generar tareas olfativas en un equipo de resonancia magnética funcional (fMRI). Material y métodos: Estudiamos 10 sujetos normales: 5 varones y 5 mujeres. El olfatómetro está dise ̃ nado para que el estímulo que produce se sincronice con el equipo de fMRI mediante la se ̃ nal desencadenante que suministra el propio equipo. El olfatómetro es capaz de: selec- cionar el olor, secuenciar los distintos olores, programar la frecuencia y duración de los olores y controlar la intensidad del olor. El paradigma utilizado responde a un dise ̃ no de activación asociada a eventos, en el que la duración del bloque de activación y de reposo es de 15 s. La duración del estímulo olfativo (butanol, menta o café) es de 2 segundos, durante toda la serie que consta de 9 ciclos. Resultados: Se ha observado reactividad (contraste BOLD) en las diferentes áreas cerebrales involucradas en las tareas olfativas: bulbo olfatorio, córtex entorrinal (4%), amigdala (2,5%) y córtex temporoparietal. Las áreas relacionadas con integración de las emociones tienen una reactividad mayor. Conclusiones: El dispositivo propuesto nos permite controlar de forma automática y sincronizada los olores necesarios para estudiar la actividad de las áreas olfatorias cerebrales mediante fMRI.
Resumo:
La microestructura (en el rango 0.1?100 ?m) tiene un importante impacto en el procesado y propiedades físico-químicas y organolépticas de los alimentos, tal y como se refleja en la propuesta del proyecto europeo INSIDEFOOD (Integrated sensing and imaging devices for designing, monitoring and controlling microstructure of foods) que utiliza matrices alimentarias artificiales a base de geles y espumas como modelos estandarizados para el estudio de la microestructura. Concretamente se ha trabajado con espumas y geles azucarados (a base de fructosa), espumas no azucaradas (0% fructosa, a base de agarosa), como símiles de alimentos de elevada porosidad y geles de gelatina comúnmente utilizados como símiles de productos cárnicos. El objetivo de este trabajo es el estudio no invasivo de la microestructura de estos geles y espumas mediante Resonancia Magnética Nuclear (NMR): tanto tomografía (MRI), como relaxometría 2D, así como la implementación de herramientas de análisis de imagen, empleando el entorno de Matlab®: segmentación, filtros morfológicos y análisis de textura. Este procedimiento permite evaluar la distribución y disponibilidad del agua, así como distribución y tamaño de poros, entre otros parámetros de interés.
Resumo:
Algunas taquicardias ventriculares (TV) posinfarto se localizan en el epicardio. La identificación de diferencias en el sustrato de las TV endocárdicas y epicárdicas permitiría definir una mejor estrategia de ablación.