991 resultados para Heart catheterization


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Clinical studies evaluating the use of phenylephrine in septic shock are lacking. The present study was designed as a prospective, crossover pilot study to compare the effects of norepinephrine (NE) and phenylephrine on systemic and regional hemodynamics in patients with catecholamine-dependent septic shock. In 15 septic shock patients, NE (0.82 +/- 0.69 mug.kg.min) was replaced with phenylephrine (4.39 +/- 5.23 mug.kg.min) titrated to maintain MAP between 65 and 75 mmHg. After 8 h of phenylephrine infusion treatment was switched back to NE. Data from right heart catheterization, acid-base balance, thermo-dye dilution catheter, gastric tonometry, and renal function were obtained before, during, and after replacing NE with phenylephrine. Variables of systemic hemodynamics, global oxygen transport, and acid-base balance remained unchanged after replacing NE with phenylephrine except for a significant decrease in heart rate (phenylephrine, 89 +/- 18 vs. NE, 93 +/- 18 bpm; P < 0.05). However, plasma disappearance rate (phenylephrine, 13.5 +/- 7.1 vs. NE, 16.4 +/- 8.7%.min) and clearance of indocyanine green (phenylephrine, 330 +/- 197 vs. NE, 380 +/- 227mL.min.m), as well as creatinine clearance (phenylephrine, 81.3 +/- 78.4 vs. NE, 94.3 +/- 93.5 mL.min) were significantly decreased by phenylephrine infusion (each P < 0.05). In addition, phenylephrine increased arterial lactate concentrations as compared with NE infusion (1.7 +/- 1.0 vs. 1.4 +/- 1.1 mM; P < 0.05). After switching back to NE, all variables returned to values obtained before phenylephrine infusion except creatinine clearance and gastric tonometry values. Our results suggest that for the same MAP, phenylephrine causes a more pronounced hepatosplanchnic vasoconstriction as compared with NE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG 2006 ± 586 vs. LEF-LG 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG 6.9 ± 1.9 vs. LEF-LG 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG 71.7% vs. LEF-LG 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Pulmonary hypertension (PH) frequently coexists with severe aortic stenosis, and PH severity has been shown to predict outcomes after transcatheter aortic valve implantation (TAVI). The effect of PH hemodynamic presentation on clinical outcomes after TAVI is unknown. METHODS AND RESULTS Of 606 consecutive patients undergoing TAVI, 433 (71.4%) patients with severe aortic stenosis and a preprocedural right heart catheterization were assessed. Patients were dichotomized according to whether PH was present (mean pulmonary artery pressure, ≥25 mm Hg; n=325) or not (n=108). Patients with PH were further dichotomized by left ventricular end-diastolic pressure into postcapillary (left ventricular end-diastolic pressure, >15 mm Hg; n=269) and precapillary groups (left ventricular end-diastolic pressure, ≤15 mm Hg; n=56). Finally, patients with postcapillary PH were divided into isolated (n=220) and combined (n=49) subgroups according to whether the diastolic pressure difference (diastolic pulmonary artery pressure-left ventricular end-diastolic pressure) was normal (<7 mm Hg) or elevated (≥7 mm Hg). Primary end point was mortality at 1 year. PH was present in 325 of 433 (75%) patients and was predominantly postcapillary (n=269/325; 82%). Compared with baseline, systolic pulmonary artery pressure immediately improved after TAVI in patients with postcapillary combined (57.8±14.1 versus 50.4±17.3 mm Hg; P=0.015) but not in those with precapillary (49.0±12.6 versus 51.6±14.3; P=0.36). When compared with no PH, a higher 1-year mortality rate was observed in both precapillary (hazard ratio, 2.30; 95% confidence interval, 1.02-5.22; P=0.046) and combined (hazard ratio, 3.15; 95% confidence interval, 1.43-6.93; P=0.004) but not isolated PH patients (P=0.11). After adjustment, combined PH remained a strong predictor of 1-year mortality after TAVI (hazard ratio, 3.28; P=0.005). CONCLUSIONS Invasive stratification of PH according to hemodynamic presentation predicts acute response to treatment and 1-year mortality after TAVI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In 2003 there was an increase in the use of pulmonary artery catheters in Australia from 12, 000 to 16, 000 units in intensive care and peri-operative care. This survey of intensive care nurses in five intensive care units in Queensland addressed knowledge of use, safety and complications of the pulmonary artery catheter, using a previously validated 31 question multiple choice survey. One hundred and thirty-nine questionnaires were completed, a response rate of 46%. The mean score was 13.3, standard deviation +/-4.2 out of a total of 31 (42.8% correct). The range was 4 to 25. Scores were significantly higher in those participants with more ICU experience, higher nursing grade, a higher self-assessed level of knowledge and greater frequency of PAC supervision. There was no significant correlation between total score and hospital- or university-based education, or total score and public or private hospital participants. Fifty-one per cent were unable to correctly identify the significant pressure change as the catheter is advanced from the right ventricle to the pulmonary artery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Early detection of right ventricular (RV) involvement in chronic pulmonary hypertension (PH) is essential due to prognostic implications. T1 mapping by cardiac magnetic resonance (CMR) has emerged as a noninvasive technique for extracellular volume fraction (ECV) quantification. We assessed the association of myocardial native T1 time and equilibrium contrast ECV (Eq-ECV) at the RV insertion points with pulmonary hemodynamics and RV performance in an experimental model of chronic PH. Right heart catheterization followed by immediate CMR was performed on 38 pigs with chronic PH (generated by surgical pulmonary vein banding) and 6 sham-operated controls. Native T1 and Eq-ECV values at the RV insertion points were both significantly higher in banded animals than in controls and showed significant correlation with pulmonary hemodynamics, RV arterial coupling, and RV performance. Eq-ECV values also increased before overt RV systolic dysfunction, offering potential for the early detection of myocardial involvement in chronic PH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impaired respiratory function (IRF) during procedural sedation and analgesia (PSA) poses considerable risk to patient safety as it can lead to inadequate oxygenation and ventilation. Risk factors that can be screened prior to the procedure have not been identified for the cardiac catheterization laboratory (CCL).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Genetic manipulation to reverse molecular abnormalities associated with dysfunctional myocardium may provide novel treatment. This study aimed to determine the feasibility and functional consequences of in vivo beta-adrenergic receptor kinase (betaARK1) inhibition in a model of chronic left ventricular (LV) dysfunction after myocardial infarction (MI). METHODS AND RESULTS: Rabbits underwent ligation of the left circumflex (LCx) marginal artery and implantation of sonomicrometric crystals. Baseline cardiac physiology was studied 3 weeks after MI; 5x10(11) viral particles of adenovirus was percutaneously delivered through the LCx. Animals received transgenes encoding a peptide inhibitor of betaARK1 (Adeno-betaARKct) or an empty virus (EV) as control. One week after gene delivery, global LV and regional systolic function were measured again to assess gene treatment. Adeno-betaARKct delivery to the failing heart through the LCx resulted in chamber-specific expression of the betaARKct. Baseline in vivo LV systolic performance was improved in Adeno-betaARKct-treated animals compared with their individual pre-gene delivery values and compared with EV-treated rabbits. Total beta-AR density and betaARK1 levels were unchanged between treatment groups; however, beta-AR-stimulated adenylyl cyclase activity in the LV was significantly higher in Adeno-betaARKct-treated rabbits compared with EV-treated animals. CONCLUSIONS: In vivo delivery of Adeno-betaARKct is feasible in the infarcted/failing heart by coronary catheterization; expression of betaARKct results in marked reversal of ventricular dysfunction. Thus, inhibition of betaARK1 provides a novel treatment strategy for improving the cardiac performance of the post-MI heart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Genetic modulation of ventricular function may offer a novel therapeutic strategy for patients with congestive heart failure. Myocardial overexpression of beta(2)-adrenergic receptors (beta(2)ARs) has been shown to enhance contractility in transgenic mice and reverse signaling abnormalities found in failing cardiomyocytes in culture. In this study, we sought to determine the feasibility and in vivo consequences of delivering an adenovirus containing the human beta(2)AR cDNA to ventricular myocardium via catheter-mediated subselective intracoronary delivery. METHODS AND RESULTS: Rabbits underwent percutaneous subselective catheterization of either the left or right coronary artery and infusion of adenoviral vectors containing either a marker transgene (Adeno-betaGal) or the beta(2)AR (Adeno-beta(2)AR). Ventricular function was assessed before catheterization and 3 to 6 days after gene delivery. Both left circumflex- and right coronary artery-mediated delivery of Adeno-beta(2)AR resulted in approximately 10-fold overexpression in a chamber-specific manner. Delivery of Adeno-betaGal did not alter in vivo left ventricular (LV) systolic function, whereas overexpression of beta(2)ARs in the LV improved global LV contractility, as measured by dP/dt(max), at baseline and in response to isoproterenol at both 3 and 6 days after gene delivery. CONCLUSIONS: Percutaneous adenovirus-mediated intracoronary delivery of a potentially therapeutic transgene is feasible, and acute global LV function can be enhanced by LV-specific overexpression of the beta(2)AR. Thus, genetic modulation to enhance the function of the heart may represent a novel therapeutic strategy for congestive heart failure and can be viewed as molecular ventricular assistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The safe and successful performance of a central venous catheterization (CVC) requires a specific knowledge of anatomy in addition to a working knowledge. Misunderstanding the anatomy may result in failure or complications. This review aims to aid understanding of the anatomical framework, pitfalls, and complications of CVC of the subclavian (SCV). CVC is common practice amongst surgeons, anesthesiologists, and emergency room physicians during the preparations for major surgical procedures such as open-heart surgery, as well as, for intensive care monitoring and rapid restoration of blood volume. Associated with this technique are certain anatomical pitfalls and complications that can be successfully avoided if one possesses a thorough knowledge of the contraindications, regional anatomy, and rationale of the technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study investigates the feasibility of a new application able to check the heart failure status in a patient through the estimation of the venous distension. In this way it would be possible to follow up patients, avoiding invasive or expensive exams such as cardiac catheterization and echocardiography. Moreover, the devices would also be able to diagnose the decline of the disease, in order to allow a new adaptation to therapy, and vice versa to check the improvement in the patient’s conditions after the CRT device implant. This thesis is essentially divided into three parts: an analytical model was used to obtain an estimation of the error committed for the calculation of the CSA and to understand how the accuracy and sensitivity depend on the different configurations of the electrodes and the catheter position inside the vein; secondly, an in-vitro experiment was carried out in order to verify the practical feasibility for these kinds of measurements, in a very simplified model; in the end, several animal experiments were done to test the in-vivo practicability of the proposed method. The obtained results showed the feasibility of this approach. In fact, the error committed in the estimation of CSA, during the animal experiments, can be considered acceptable (CSAerror_max ≈ -14%). Moreover, it has been demonstrated that the conductance catheter allows assessing, not only the vein CSA, but also the breathing of the animal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE(S): Even though the mechanism is not clearly understood, direct intramyocardial cell transplantation has demonstrated potential to treat patients with severe heart failure. We previously reported on the bioengineering of myoblast-based constructs. We investigate here the functional outcome of infarcted hearts treated by implantation of myoblast-seeded scaffolds. METHODS: Adult Lewis rats with echocardiography-confirmed postinfarction reduced ejection fraction (48.3% +/- 1.1%) were randomized to (1) implantation of myoblast-seeded polyurethane patches at the site of infarction (PU-MyoB, n = 11), (2) implantation of nonseeded polyurethane patches (PU, n = 11), (3) sham operation (Sham, n = 12), and (4) direct intramyocardial myoblast injection (MyoB, n = 11). Four weeks later, the functional assessment by echocardiography was repeated, and we additionally performed left ventricular catheterization plus histologic studies. RESULTS: The ejection fraction significantly decreased in the PU (39.1% +/- 2.3%; P = .02) and Sham (39.9% +/- 3.5%; P = .04) groups, whereas it remained stable in the PU-MyoB (48.4% +/- 3.1%) and MyoB (47.9% +/- 3.0%) groups during the observation time. Similarly, left ventricular contractility was significantly higher in groups PU-MyoB (4960 +/- 266 mm Hg/s) and MyoB (4748 +/- 304 mm Hg/s) than in groups PU (3909 +/- 248 mm Hg/s, P = .01) and Sham (4028 +/- 199 mm Hg/s, P = .01). Immunohistology identified a high density of myoblasts within the seeded scaffolds without any migration toward the host cardiac tissue and no evidence of cardiac cell differentiation. CONCLUSIONS: Myoblast-seeded polyurethane scaffolds prevent post-myocardial infarction progression toward heart failure as efficiently as direct intramyocardial injection. The immunohistologic analysis suggests that an indirect mechanism, potentially a paracrine effect, may be assumed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.