867 resultados para Blood Glucose


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new generation of blood glucose meters is now available for use by people with diabetes and health professionals, but little independent evaluation data is available. Previous models are prone to a variety of errors. We compared the accuracy, precision and features of the six latest meters available in Australia as of 1996. Meters studied were the Mini-Accutrend and Advantage (Boehringer Mannheim), Precision QID and Companion 2 (MediSense), Glucometer Elite (Bayer) and Lynx (National Diagnostic Products). We measured the blood glucose levels of 50 people with diabetes with these meters, and compared them to a reference method (YSI glucose analyser). Error grid analysis confirmed that accuracy of all meters was sufficient for their intended use as patient monitors. Precision was assessed using 25 samples from control solutions provided for each meter, and the coefficient of variation calculated. Improvements in strip and meter technology in some models have increased ease of use and reduced the likelihood of user error. This study, when considered with individual preferences for various features and price should assist patients in choosing a new blood glucose meter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE--We examined the associations of physical activity with fasting plasma glucose (FPG) and with 2-h postload plasma glucose (2-h PG) in men and women with low, moderate, and high waist circumference.

RESEARCH DESIGN AND METHODS--The Australian Diabetes, Obesity and Lifestyle (AusDiab) study provided data on a population-based cross-sectional sample of 4,108 men and 5,106 women aged [greater than or equal to] 25 years without known diabetes or health conditions that could affect physical activity. FPG and 2-h PG were obtained from an oral glucose tolerance test. Self-reported physical activity level was defined according to the current public health guidelines as active ([greater than or equal to] 150 min/week across five or more sessions) or inactive (<150 min/week and/or less than five sessions). Sex-specific quintiles of physical activity time were used to ascertain dose response.

RESULTS--Being physically active and total physical activity time were independently and negatively associated with 2-h PG. When physical activity level was considered within each waist circumference category, 2-h PG was significantly lower in active high-waist circumference women ([beta] -0.30 [95% CI -0.59 to -0.01], P = 0.044) and active low-waist circumference men ([beta] -0.25 [-0.49 to -0.02], P = 0.036) compared with their inactive counterparts. Considered across physical activity and waist circumference categories, 2-h PG levels were not significantly different between active moderate-waist circumference participants and active low-waist circumference participants. Associations between physical activity and FPG were nonsignificant.

CONCLUSIONS--There are important differences between 2-h PG and FPG related to physical activity. It appears that 2-h PG is more sensitive to the beneficial effects of physical activity, and these benefits occur across the waist circumference spectrum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective
To determine the accuracy and appropriateness of capillary blood glucose testing in population surveys.
Materials and methods

Capillary blood glucose using the Rochec ACCU-CHEK instrument and Advantage 11 Test Strips was compared to a laboratory instrument. Three independent cross-sectional risk factor surveys (n=1432) and baseline individuals from the Greater Green Triangle Diabetes Prevention Project (n=341) provided both fasting plasma and capillary blood glucose measurements. Accuracy of capillary glucoses was assessed using the ISO 15197 standard. The median age of the participants was 71years, ranging from 25 to 84years. There were 799 males and 974 females.
Results
Capillary glucose method had poorer precision at lower concentrations (CV: 9.50%, mean=3.09mmol/L, CV: 4.90%, mean=16.78mmol/L, n=233 replicates). Individual discrepancies were seen across the measuring range (2.8–19.9mmol/L, n=1773). In total, 94.5% of results fell within the minimum acceptable accuracy standards. This was slightly short of the 95% of results required to meet the ISO 15197 standard. The prevalence of diabetes in the study population using glucose 7.0mmol/L was 2.4% (95%CI 1.8–3.3%) according to fasting plasma glucose and 2.8% (2.1–3.8%) according to fasting capillary glucose. The lower WHO-defined cut-off of 6.1mmol/L for capillary blood glucose testing gave a prevalence of 10.7% (9.0–12.5%).
Conclusions
This study of matched capillary and plasma glucose results concludes that while it is appropriate to use fasting capillary glucose levels to determine the prevalence of diabetes in populations, it should not be used to reliably diagnose diabetes in individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces a method of modeling noninvasive glucose sensing for patients who suffer from diabetes mellitus. The proposed technique involves simulation of light propagation through biological tissue with an embedded photonic crystal. The proposed detection technique is Raman spectroscopy and the use of the photonic crystal enables the enhancement of Raman scattering by engineering the photon density of states. Further enhancement can be achieved using noble metal clusters which result in surface enhanced Raman scattering and has the ability to provide enhancements of up to a million times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the effect of increased blood glucose availability on glucose kinetics during exercise. Five trained men cycled for 40 min at 77 ± 1% peak oxygen uptake on two occasions. During the second trial (Glu), glucose was infused at a rate equal to the average hepatic glucose production (HGP) measured during exercise in the control trial (Con). Glucose kinetics were measured by a primed continuous infusion ofd-[3-3H]glucose. Plasma glucose increased during exercise in both trials and was significantly higher in Glu. HGP was similar at rest (Con, 11.4 ± 1.2; Glu, 10.6 ± 0.6 μmol ⋅ kg−1 ⋅ min−1). After 40 min of exercise, HGP reached a peak of 40.2 ± 5.5 μmol ⋅ kg−1 ⋅ min−1in Con; however, in Glu, there was complete inhibition of the increase in HGP during exercise that never rose above the preexercise level. The rate of glucose disappearance was greater (P < 0.05) during the last 15 min of exercise in Glu. These results indicate that an increase in glucose availability inhibits the rise in HGP during exercise, suggesting that metabolic feedback signals can override feed-forward activation of HGP during strenuous exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We previously used Gene Expression Signature technology to identify methazolamide (MTZ) and related compounds with insulin sensitizing activity in vitro. The effects of these compounds were investigated in diabetic db/db mice, insulin-resistant diet-induced obese (DIO) mice, and rats with streptozotocin (STZ)-induced diabetes. MTZ reduced fasting blood glucose and HbA1c levels in db/db mice, improved glucose tolerance in DIO mice, and enhanced the glucose-lowering effects of exogenous insulin administration in rats with STZ-induced diabetes. Hyperinsulinemic-euglycemic clamps in DIO mice revealed that MTZ increased glucose infusion rate and suppressed endogenous glucose production. Whole-body or cellular oxygen consumption rate was not altered, suggesting MTZ may inhibit glucose production by different mechanism(s) to metformin. In support of this, MTZ enhanced the glucose-lowering effects of metformin in db/db mice. MTZ is known to be a carbonic anhydrase inhibitor (CAI); however, CAIs acetazolamide, ethoxyzolamide, dichlorphenamide, chlorthalidone, and furosemide were not effective in vivo. Our results demonstrate that MTZ acts as an insulin sensitizer that suppresses hepatic glucose production in vivo. The antidiabetic effect of MTZ does not appear to be a function of its known activity as a CAI. The additive glucose-lowering effect of MTZ together with metformin highlights the potential utility for the management of type 2 diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To compare the effectiveness and acceptability of self-monitoring of blood glucose with self-monitoring of urine glucose in adults with newly diagnosed Type 2 diabetes. METHODS: We conducted a multi-site cluster randomized controlled trial with practice-level randomization. Participants attended a structured group education programme, which included a module on self-monitoring using blood glucose or urine glucose monitoring. HbA1c and other biomedical measures as well as psychosocial data were collected at 6, 12 and 18 months. A total of 292 participants with Type 2 diabetes were recruited from 75 practices. RESULTS: HbA1c levels were significantly lower at 18 months than at baseline in both the blood monitoring group [mean (se) -12 (2) mmol/mol; -1.1 (0.2) %] and the urine monitoring group [mean (se) -13 (2) mmol/mol; -1.2 (0.2)%], with no difference between groups [mean difference adjusted for cluster effect and baseline value = -1 mmol/mol (95% CI -3, 2); -0.1% (95% CI -0.3, 0.2)]. Similar improvements were observed for the other biomedical outcomes, with no differences between groups. Both groups showed improvements in total treatment satisfaction, generic well-being, and diabetes-specific well-being, and had a less threatening view of diabetes, with no differences between groups at 18 months. Approximately one in five participants in the urine monitoring arm switched to blood monitoring, while those in the blood monitoring arm rarely switched (18 vs 1% at 18 months; P < 0.001). CONCLUSIONS: Participants with newly diagnosed Type 2 diabetes who attended structured education showed similar improvements in HbA1c levels at 18 months, regardless of whether they were assigned to blood or urine self-monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proposição foi realizada, no período pós-operatório imediato, em 40 ratos Wistar, distribuídos por sorteio em doi grupos: grupo NC, vinte ratos correspondentes ao grupo controle, não diabético, submetidos a operação simulada e o grupo PT, 20 ratos correspondentes ao grupo diabético que recebeu transplante de pâncreas heterotópico de ratos Wistar normais. Durante sete dias, antes do transplante, e 1, 3, 6, 12, 24, 48, 72, 96 horas após, determinava-se a glicose sanguínea, a insulina plasnática e o glucagon. Estes parâmetros eram obtidos também do grupo NC. Diabetes mellitus experimental era induzida pela administração intravenosa de aloxana. O grupo PT era imunosuprimido com ciclosporina A. O grupo NC apresentou níveis normais de glicose sanguínea, de insulina plásmica e de glucagon, durante todo o experimento. Foi encontrada nítida hiperinsulinemia no sangue venoso periférico do grupo PT. A insulina plasmática era significantemente maior no grupo PT comparada ao grupo NC começando 72 horas após o transplante. O glucagon plasmático, elevado no período pré-transplante, não se alterou após o transplante. Apesar de hiperinsulinemia e hiperglucagonemia, os níveis de glicose sanguínea eram elevados 6 horas após o transplante e mantiveram-se normais após este período. Considerando-se os níveis de glicose sanguínea 12 horas pós-transplante, não houve diferença estatisticamente significante entre os grupos PT e NC, até o sacrifício.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The equilibrium point between blood lactate production and removal (La-min(-)) and the individual anaerobic threshold (IAT) protocols have been used to evaluate exercise. During progressive exercise, blood lactate [La-](b), catecholamine and cortisol concentrations, show exponential increases at upper anaerobic threshold intensities. Since these hormones enhance blood glucose concentrations [Glc](b), this study investigated the [Glc] and [La-](b) responses during incremental tests and the possibility of considering the individual glucose threshold (IGT) and glucose minimum;(Glc(min)) in addition to IAT and La-min(-) in evaluating exercise. A group of 15 male endurance runners ran in four tests on the track 3000 m run (v(3km)); IAT and IGT- 8 x 800 m runs at velocities between 84% and 102% of v(3km); La-min(-) and Glc(min) - after lactic acidosis induced by a 500-m sprint, the subjects ran 8 x 800 m at intensities between 87% and 97% of v(3km); endurance test (ET)- 30 min at the velocity of IAT. Capillary blood (25 mu l) was collected for [La-](b) and [Glc](b) measurements. The TAT and IGT were determined by [La-](b) and [Glc](b) kinetics during the second test. The La-min(-) and Glc(min) were determined considering the lowest [La-] and [Glc](b) during the third test. No differences were observed (P < 0.05) and high correlations were obtained between the velocities at IAT [283 (SD 19) and IGT 281 (SD 21)m. min(-1); r = 0.096; P < 0.001] and between La,, [285 (SD 21)] and Glc(min) [287 (SD 20) m. min(-1) = 0.77; P < 0.05]. During ET, the [La-](b) reached 5.0 (SD 1.1) and 5.3 (SD 1.0) mmol 1(-1) at 20 and 30 min, respectively (P > 0.05). We concluded that for these subjects it was possible to evaluate the aerobic capacity by IGT and Glc(min), as well as by IAT and La-min(-).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present investigation was to determine the course of maternal blood glucose levels in pregnant rats and its repercussions on the glucose levels and pancreas of their newborn pups. Diabetes was induced by alloxan (42 mg/kg body weight) and streptozotocin (40 mg/kg). Sixty-two pregnant Wistar rats weighing 180 to 250 g were divided into a control group and two groups with moderate (120 to 200 mg/dl glucose) and severe diabetes (greater than 200 mg/dl glucose), respectively. Blood glucose levels were measured in the dams on the 1st, 14th, and 21st days of pregnancy and in the pups at birth. The results were pooled for each litter. The fetal pancreases were removed after cesarian section performed on the 21st day of pregnancy, pooled for each litter and processed for histopathologic examination by light microscopy. Maternal blood glucose levels were significantly increased compared with the first day of pregnancy in both normal and diabetic rats starting on the 14th day of pregnancy. Fetal blood glucose levels correlated with maternal levels. The histopathologic changes characterized by vacuolization and basophilia of the cytoplasm of endocrine pancreas of newborn pups from darns with moderate or severe diabetes suggested pancreatic hyperactivity.