60 resultados para septo-optic dysplasia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There were four principal sections to the work: 1. Investigation of ocular and systemic vascular risk factors in POAG. The principal findings of this work were: a). Glaucoma patients exhibit an anticipatory reaction to the physical stress, similar to subjects at risk for cardiovascular diseases; a blunted BP response and a reduction in ONH blood flow in response to cold provocation was also recorded. b). Silent myocardial ischaemic episodes occurred during peaks in systemic BP and HR. c). Independent of a positive history for cardiovascular diseases, patients suffering from POAG demonstrate a blunt circadian rhythm of the ANS. 2. Assessment of the relationship between vascular and systemic vascular risk factors in GON. The principal findings of this work were: a). POAG patients demonstrate a high sympathetic tonus over a 24-h period. b). POAG patients with lower OBF demonstrate both 24-h systemic BP and HRV abnormalities. c). OBF alterations observed in some glaucoma patients could be either primary or secondary to systemic haemodynamic disturbances and not a consequence of ONH damage. 3. Assessment of the level of systemic anti-oxidant defence in POAG patients. The principal finding of this work was: Patients suffering from POAG demonstrated significantly lower GSH and t-GSH levels than normal controls. 4. Investigation of the effect of treatment with latanoprost 0.005% on visual function and OBF. The findings of this work were: a). Treatment with latanoprost 0.005% resulted in a significant decrease in IOP and increase in OPP. VF damage progression has also been stopped. b). Treatment with latanoprost 0.005% resulted in a significant increase in the OBF parameters measured at the ONH and peripapillary retina levels. Finally, the importance of a clear protocol for managing new POAG cases is highlighted and a clinical conduit is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of optic nerve head (ONH) axons in primary open angle glaucoma (POAG) has been attributed to both mechanical and vascular factors. Confocal scanning laser ophthalmoscopy (cSLO) provides a promising tool for the topographic follow-up of the ONH in glaucoma, while scanning laser Doppler flowmetry (SLDF) facilitates the rapid non-invasive assessment of retinal capillary blood flow. The purposes of these investigations were to optimise the techniques and explore their potential to classify and monitor disease. Preliminary investigations explored the reproducibility and validity of cSLO and SLDF and showed that: For cSLO: In a model eye, measurements are accurate over a range of axial lengths. For best reproducibility, seven images per visit are required, with a contour line located on Elschnig's scleral ring and transferred automatically between images. For SLDF: Three perfusion images are required for optimum reproducibility. Physiological changes induced by gas perturbation can be measured. Cross-sectional comparison of groups of normal subjects and early POAG patients showed that: cSLO parameters differentiate the early POAG group. Blood volume measured by SLDF showed group differences in superior nasal retina only. Longitudinal investigation of ONH topography, haemodynamic and visual field indices in normal subjects and POAG patients showed that: cSLO detects topographical change over time more frequently in the POAG group. Important parameters include: C:D area ratio, cup and rim area, mean depth in contour, volumes above and below reference and surface. Factor analysis identified "cup" and "rim" factors that can be used to detect change over time in individual patients. Blood flow changes were most apparent in the inferior nasal peripapillary retina of the POAG group. Perimetry is of clinical value for the identification of glaucoma but is less sensitive than cSLO for monitoring glaucomatous change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time to the authors' knowledge, fiber Bragg gratings (FBGs) with >80° tilted structures have been fabricated and characterized. Their performance in sensing temperature, strain, and the surrounding medium's refractive index was investigated. In comparison with normal FBGs and long-period gratings (LPGs), >80° tilted FBGs exhibit significantly higher refractive-index responsivity and lower thermal cross sensitivity. When the grating sensor was used to detect changes in refractive index, a responsivity as high as 340nm/refractive-index unit near an index of 1.33 was demonstrated, which is three times higher than that of conventional LPGs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster section INTRODUCTION. Retrospective Analysis PURPOSE. To evaluate the morphology and location of optic disc haemorrhages (ODH) identified at diabetic retinopathy (DR) screening to establish whether particular ODH are predictive of ocular disease (e.g. glaucoma). METHODS. Retrospective analysis of 77 patients who presented with ODH at DR screening in the Birmingham and Black Country screening programme between June 2009-March 2010. Mean age was 71 years (range 39-89). Cup/disc ratio (CDR), location and morphology of the haemorrhage were recorded. The outcome of the referral and the status of the ODH were followed up a year later. RESULTS. Of the 77 referred, 34 patients were unassessed for possible glaucoma. Of the 43 patients that were assessed in the hospital eye service for glaucoma, 11 (26%) were diagnosed with glaucoma. These glaucoma patients mostly presented with flame haemorrhages (64%) and blot haemorrhages (36%). Haemorrhages tended to adjoin the margin of the OD (64%), and were more commonly flame shaped (64%). They less commonly occurred in the optic disc itself (36%), and were all blot shaped. The OD Cup/disc ratio (CDR) of the patients with glaucoma (n=11) ranged from 0.33-0.57. It is interesting to note the highest CDR was 0.68 in the 77 patients referred. 32 patients were confirmed as not having glaucoma. 24 (75%) of these patients presented with an ODH adjoining the margin, of which 20 (83%) were flame, and 4 blot (17%) shaped. Only 8 (25%) presented with an ODH in the OD, of which 6 (75%) were blot shaped. One year follow up of the 77 referred cases revealed that the ODH resolved in 45 (57%) patients while 10 (13%) still had an ODH present. 15 (21%) were still under ophthalmology hence digital retinal photos were not available for assessment. Six patients (8%) (age range 71-91 years) died within the year, and one lost to follow up. CONCLUSIONS. The results suggest that a significant number of patients with ODH have glaucoma and that the differing morphology of the haemorrhage is not a major predictor i.e. blot versus flame shaped, adjoining or in the optic disc. The cup/disc ratio did not predict glaucoma either.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free paper session INTRODUCTION. Microaneurysms and haemorrhages within the macula area are a poor predictor of macular oedema as shown by optical coherence tomography (OCT). Our research suggests that it is safe and cost effective to screen patients who present with these surrogate markers annually. PURPOSE. To determine whether microaneurysms (ma) and haemorrhages (hm) within one optic disc diameter of the fovea (ma/hm<1DD) are significant predictors of macular oedema. METHODS. Data were collected over a one-year period from patients attending digital diabetic retinopathy screening. Patients who presented with ma/hm<1DD also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Macular oedema was identified by thickening on the OCT cross-sections. Patients were split into two groups. Group one (325 eyes) included those with best VA?6/9 and group two (30 eyes) with best VA =6/12. Only patients who had no other referable features of diabetic retinopathy were selected. RESULTS. In group one, 6 (1.8%) out of 325 eyes showed thickening on the OCT and were referred to hospital eye service (HES) for further investigation. In group two, 6 (20%) out of 30 eyes showed thickening and were referred to HES. CONCLUSIONS. Ma/hm<1DD become more significant predictors of macular oedema when VA is reduced. Results confirm the grading criteria concerning microaneurysms predicting macular oedema for referable maculopathy in the English national screening programme. OCT is a useful method to accurately identify patients requiring referral to HES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the density and cross-sectional area of axons in the optic nerve in elderly control subjects and in cases of Alzheimer's disease (AD) using an image analysis system. Methods: Sections of optic nerves from control and AD patients were stained with toluidine blue to reveal axon profiles. Results: The density of axons was reduced in both the center and peripheral portions of the optic nerve in AD compared with control patients. Analysis of axons with different cross-sectional areas suggested a specific loss of the smaller sized axons in AD, i.e., those with areas less that 1.99 μm2. An analysis of axons >11 μm2 in cross-sectional area suggested no specific loss of the larger axons in this group of patients. Conclusions: The data suggest that image analysis provides an accurate and reproducible method of quantifying axons in the optic nerve. In addition, the data suggest that axons are lost throughout the optic nerve with a specific loss of the smaller-sized axons. Loss of the smaller axons may explain the deficits in color vision observed in a significant proportion of patients with AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-optical data processing is expected to play a major role in future optical communications. Nonlinear effects in optical fibers have attractive applications in optical signal processing. In this paper, we review our recent advances in developing all-optical processing techniques at high speed based on optical fiber nonlinearities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose to apply a large predispersion (having the same sign as the transmission fiber) to an optical signal before the uncompensated fiber transmission in coherent communication systems. This technique is aimed at simplifica- tion of the following digital signal processing of nonlinear impairments. We derive a model describing pulse propagation in the dispersion-dominated nonlinear fiber channel. In the limit of very strong initial predispersion, the nonlinear propagation equations for each Fourier mode become local and decoupled. This paves the way for new techniques to manage fiber nonlinearity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work addresses the control of the mPOF Bragg grating spectrum properties through acousto-optic modulation. For the first time, the interaction of a flexural acoustic wave, generated by longitudinal excitation of different frequencies, with the Bragg grating will be presented. Also it will be demonstrated the quasi linear relationship between PZT load and maximum reflected power/ 3dB bandwidth of the reflected spectrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a theoretical study of polarization impairments in periodically spun fiber Raman amplifiers. Based on the Stochastic Generator approach we have derived averaged equations to calculate polarization dependent gain and mean-square gain fluctuations. We show that periodically spun fiber can work as a Raman polarizer but it suffers from increased polarization dependent gain and gain fluctuations. Unlike this, application of a depolarizer can result in suppression of polarization dependent gain and gain fluctuations. We demonstrate that it is possible to design a new fiber Raman polarizer by combining a short fiber without spin and properly chosen parameters and a long periodically spun fiber. This polarizer provides almost the same polarization pulling for all input signal states of polarization and so has very small polarization dependent gain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fine control of the microstructured polymer fiber Bragg grating spectrum properties, such as maximum reflected power and 3-dB bandwidth, through acousto-optic modulation is presented. For simulation purposes, the device is modelled as a single structure, comprising a silica horn and a fiber Bragg grating. For similar sized structures a good correlation between the numerical results and the experimental data is obtained, allowing the strain field to be completely characterized along the whole structure. It is also shown that the microstructured polymer fiber Bragg grating requires less effort from the piezoelectric actuator to produce modification in the grating spectrum when compared with a silica fiber Bragg grating. This technique has potential to be applied on tunable optical filters and tunable cavities for photonic applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prototype fibre-optic system using interferometric wavelength-shift detection, capable of multiplexing up to 32 fibre-optic Bragg grating strain and temperature sensors with identical characteristics, has been demonstrated. This system is based on a spatially multiplexed scheme for use with fibre-based low-coherence interferometric sensors, reported previously. Four fibre-optic Bragg grating channels using the same fibre grating have been demonstrated for measuring quasi-static strain and temperature.