18 resultados para tolerance

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the relationship between vascular function parameters measured at the retinal and systemic level and known markers for cardiovascular risk in patients with impaired glucose tolerance (IGT). Sixty age- and gender- matched White-European adults (30 IGT and 30 normal glucose tolerance -NGT) were recruited for the study. Fasting plasma glucose, lipids and 24-hour blood pressure (BP) was measured in all subjects. Systemic vascular and endothelial function was assessed using carotid-artery intimal media thickness (cIMT) and flow mediated dilation (FMD). Retinal vascular reactivity was assessed by the Dynamic Retinal Vessel Analyser (DVA). Additionally, blood glutathione (GSH, GSSG and tGSH) and plasma von-Willebrand (vWF) factor levels were also measured. Individuals with IGT demonstrated higher BP values (p<0.001), fasting TG and TG:HDL ratios (p<0.001) than NGT subjects. Furthermore, Total:HDL-C ratios and Framingham scores were raised (p=0.010 and p<0.001 respectively). Blood glutathione levels (GSH, GSSG and tGSH) were lower (p<0.001, p=0.039 and p<0.001 respectively) while plasma vWF was increased (p=0.014) in IGT subjects compared to controls. IGT individuals also demonstrated higher IMT in right and left carotid arteries (p=0.017 and p=0.005, respectively) alongside larger brachial artery diameter (p=0.015), lower FMD% (p=0.026) and GTN induced dilation (GID) (p=0.012) than healthy controls. At the retinal arterial level, the IGT subjects showed higher baseline fluctuations (BDF) (p=0.026), longer reaction time (RT) (p=0.032) and reduced baseline-corrected flicker response (bFR) (p=0.045). In IGT subjects retinal BDF correlated with and Total:HDL (p= 0.003) and HDL-C (p= 0.004). Arterial RT also correlated with FMD (p=0.017) in IGT but not NGT subjects. In IGT individuals there is a relationship between macro- and microvascular function, as well as a direct correlation between the observed retinal microcirculatory changes and established plasma markers for CVD. Multifactorial preventive interventions to decrease vascular risk in these individuals should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the evolution of radiation damage and changes in hardness of sputter-deposited Cu/V nanolaminates upon room temperature helium ion irradiation. As the individual layer thickness decreases from 200 to 5 nm, helium bubble density and radiation hardening both decrease. The magnitude of radiation hardening becomes negligible for individual layer thickness of 2.5 nm or less. These observations indicate that nearly immiscible Cu/V interface can effectively absorb radiation-induced point defects and reduce their concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-cost, high-capacity optical transmission systems are required for metropolitan area networks. Direct-detected multi-carrier systems are attractive candidates, but polarization mode dispersion (PMD) is one of the major impairments that limits their performance. In this paper, we report the first experimental analysis of the PMD tolerance of a 288Gbit/s NRZ-OOK Coherent Wavelength Division Multiplexing system. The results show that this impairment is determined primarily by the subcarrier baud rate. We confirm the robustness of the system to PMD by demonstrating error-free performance over an unrepeatered 124km field-installed single-mode fiber with a negligible penalty of 0.3dB compared to the back-to-back measurements. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show an improved DPSK receiver design which can increase useful dispersion tolerance by up to a factor of two. The increased dispersion tolerance is achieved through optimization of the optical filter at the receiver and the delay of the Mach-Zehnder interferometer. In this paper we fully explain the concept, quantify the gain and provide an explanation for the operation of the receiver. © 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally confirm the optimum combination of modulator delay and filter bandwidth to maximize the dispersion tolerance of partial DPSK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interface effects on ion-irradiation tolerance properties are investigated in nanolayered TiN/AlN films with individual layer thickness varied from 5 nm to 50 nm, prepared by pulsed laser deposition. Evolution of the microstructure and hardness of the multilayer films are examined on the specimens before and after He ion-implantation to a fluence of 4 × 10 m at 50 keV. The suppression of amorphization in AlN layers and the reduction of radiation-induced softening are observed in all nanolayer films. A clear size-dependent radiation tolerance characteristic is observed in the nanolayer films, i.e., the samples with the optimum layer thickness from 10 nm to 20 nm show the best ion irradiation tolerance properties, and a critical layer thickness of more than 5 nm is necessary to prevent severe intermixing. This study suggests that both the interface characteristics and the critical length scale (layer thickness) contribute to the reduction of the radiation-induced damages in nitride-based ceramic materials. © 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. Setting: University vision clinic. Methods: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. Results: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F= 70.341; p< 0.001). Comparatively better acuities were observed around 180°, as anticipated (F= 3.775; p= 0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F= 2.190, p= 0.129) or high cylinder (F= 0.491, p= 0.617) or in the adapted astigmats (F= 0.120, p= 0.887). Conclusion: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect. © 2013 British Contact Lens Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate 38-Gbit/s offset-16QAM OFDM over 840km without guard interval, and numerically show that 112-Gbit/s PDM offset-QPSK OFDM achieves 23% increase in net capacity over conventional OFDM under the same transmission reach. © 2014 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates the antidiabetic potential of an enzyme-resistant analog, (Val8)GLP-1. The effects of daily administration of a novel dipeptidyl peptidase IV-resistant glucagon-like peptide-1 (GLP-1) analog, (Val8)GLP-1, on glucose tolerance and pancreatic β-cell function were examined in obese-diabetic (ob/ob) mice. Acute intraperitoneal administration of (Val8)GLP-1 (6.25-25 nmol/kg) with glucose increased the insulin response and reduced the glycemic excursion in a dose-dependent manner. The effects of (Val8)GLP-1 were greater and longer lasting than native GLP-1. Once-daily subcutaneous administration of (Val8)GLP-1 (25 nmol/kg) for 21 days reduced plasma glucose concentrations, increased plasma insulin, and reduced body weight more than native GLP-1 without a significant change in daily food intake. Furthermore, (Val8)GLP-1 improved glucose tolerance, reduced the glycemic excursion after feeding, increased the plasma insulin response to glucose and feeding, and improved insulin sensitivity. These effects were consistently greater with (Val8)GLP-1 than with native GLP-1, and both peptides retained or increased their acute efficacy compared with initial administration. (Val8)GLP-1 treatment increased average islet area 1.2-fold without changing the number of islets, resulting in an increased number of larger islets. These data demonstrate that (Val8)GLP-1 is more effective and longer acting than native GLP-1 in obese-diabetic ob/ob mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show an improved DPSK receiver design which can increase useful dispersion tolerance by up to a factor of two. The increased dispersion tolerance is achieved through optimization of the optical filter at the receiver and the delay of the Mach-Zehnder interferometer. In this paper we fully explain the concept, quantify the gain and provide an explanation for the operation of the receiver. © 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a performance evaluation of a non-conventional approach to implement phase noise tolerant optical systems with multilevel modulation formats. The performance of normalized Viterbi-Viterbi carrier phase estimation (V-V CPE) is investigated in detail for circular m-level quadrature amplitude modulation (C-mQAM) signals. The intrinsic property of C-mQAM constellation points with a uniform phase separation allows a straightforward employment of V-V CPE without the need to adapt constellation. Compared with conventional feed-forward CPE for square QAM signals, the simulated results show an enhanced tolerance of linewidth symbol duration product (ΔvTs) at a low sensitivity penalty by using feed-forward CPE structure with C-mQAM. This scheme can be easily upgraded to higher order modulations without inducing considerable complexity.