13 resultados para VALIDITY

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report results from preliminary stages of the development and validation of a scale of service leadership. Firstly, items generated from qualitative interviews are discussed and the conceptual dimensions of the service leadership scale are formulated. Following this, results from the application of Anderson and Gerbing’s (1991) substantive validity test are examined and interpreted, giving indication of further scale development issues. Finally, conclusions and future research directions are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bove, Pervan, Beatty, and Shiu [Bove, LL, Pervan, SJ, Beatty, SE, Shiu, E. Service worker role in encouraging customer organizational citizenship behaviors. J Bus Res 2009;62(7):698–705.] develop and test a latent variable model of the role of service workers in encouraging customers' organizational citizenship behaviors. However, Bove et al. [Bove, LL, Pervan, SJ, Beatty, SE, Shiu, E. Service worker role in encouraging customer organizational citizenship behaviors. J Bus Res 2009;62(7):698–705.] claim support for hypothesized relationships between constructs that, due to insufficient discriminant validity regarding certain constructs, may be inaccurate. This research comment discusses what discriminant validity represents, procedures for establishing discriminant validity, and presents an example of inaccurate discriminant validity assessment based upon the work of Bove et al. [Bove, LL, Pervan, SJ, Beatty, SE, Shiu, E. Service worker role in encouraging customer organizational citizenship behaviors. J Bus Res 2009;62(7):698–705.]. Solutions to discriminant validity problems and a five-step procedure for assessing discriminant validity then conclude the paper. This comment hopes to motivate a review of discriminant validity issues and offers assistance to future researchers conducting latent variable analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subjective measures of company performance are widely used in research and typically are interpreted as equivalent to objective measures. Yet, the assumption of equivalence is open to challenge. We compared the use of both types of measure in 3 separate samples. Findings were consistent in showing that: (a) subjective and objective measures of company performance were positively associated (convergent validity); (b) those relationships were stronger than those between measures of differing aspects of performance using the same method (discriminant validity); and (c) the relationships of subjective and objective company performance measures with a range of independent variables were equivalent (construct validity).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth in availability and ability of modern statistical software has resulted in greater numbers of research techniques being applied across the marketing discipline. However, with such advances come concerns that techniques may be misinterpreted by researchers. This issue is critical since misinterpretation could cause erroneous findings. This paper investigates some assumptions regarding: 1) the assessment of discriminant validity; and 2) what confirmatory factor analysis accomplishes. Examples that address these points are presented, and some procedural remedies are suggested based upon the literature. This paper is, therefore, primarily concerned with the development of measurement theory and practice. If advances in theory development are not based upon sound methodological practice, we as researchers could be basing our work upon shaky foundations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we examine the equilibrium states of finite amplitude flow in a horizontal fluid layer with differential heating between the two rigid boundaries. The solutions to the Navier-Stokes equations are obtained by means of a perturbation method for evaluating the Landau constants and through a Newton-Raphson iterative method that results from the Fourier expansion of the solutions that bifurcate above the linear stability threshold of infinitesimal disturbances. The results obtained from these two different methods of evaluating the convective flow are compared in the neighborhood of the critical Rayleigh number. We find that for small Prandtl numbers the discrepancy of the two methods is noticeable. © 2009 The Physical Society of Japan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we examine the equilibrium states of periodic finite amplitude flow in a horizontal channel with differential heating between the two rigid boundaries. The solutions to the Navier-Stokes equations are obtained by means of a perturbation method for evaluating the Landau coefficients and through a Newton-Raphson iterative method that results from the Fourier expansion of the solutions that bifurcate above the linear stability threshold of infini- tesimal disturbances. The results obtained from these two different methods of evaluating the convective flow are compared in the neighbourhood of the critical Rayleigh number. We find that for small Prandtl numbers the discrepancy of the two methods is noticeable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To assess the accuracy and reproducibility of biometry undertaken with the Aladdin (Topcon, Tokyo, Japan) in comparison with the current gold standard device, the IOLMaster 500 (Zeiss, Jena, Germany). Setting University Eye Clinic, Birmingham, UK and Refractive Surgery Centre, Kiel, Germany. Methods The right eye of 75 patients with cataracts and 22 healthy participants were assessed using the two devices. Measurements of axial length (AL), anterior chamber depth (ACD) and keratometry (K) were undertaken with the Aladdin and IOLMaster 500 in random order by an experienced practitioner. A second practitioner then obtained measurements for each participant using the Aladdin biometer in order to assess interobserver variability. Results No statistically significant differences ( p≥0.05) between the two biometers were found for average difference (AL)±95% CI=0.01±0.06 mm), ACD (0.00 ±0.11 mm) or mean K values (0.08±0.51 D). Furthermore, interobserver variability was very good for each parameter (weighted κ≥0.85). One patient's IOL powers could not be calculated with either biometer measurements, whereas a further three could not be analysed by the IOLMaster 500. The IOL power calculated from the valid measurements was not statistically significantly different between the biometers (p=0.842), with 91% of predictions within±0.25 D. Conclusions The Aladdin is a quick, easy-to-use biometer that produces valid and reproducible results that are comparable with those obtained with the IOLMaster 500.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Case: Beardsley Theobalds Retirement Benefit Scheme Trustees v Yardley [2011] EWHC 1380 (QB) (QBD). The recent case of Beardsley Theobalds Retirement Benefit Scheme Trustees v Yardley, nicely illustrates, inter alia, the impact of the contractual defences of undue influence and the plea of non est factum in the context of avoiding liability under leasehold guarantees, within the setting of the landlord and tenant relationship. Additionally, the case also gives us an insight into the possible application of other technical defences relating to the law of formalities for leases. Judgment in this case was handed down on September 30, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of elder abuse risk is a critical issue because a lot of cases remain hidden. Screening tools can be used to detect elder abuse. However, few tools have been developed for use with caregivers. The purpose was to develop a translation and adaptation of a Spanish version of the Caregiver Abuse Screen (CASE) and to assess its validity and reliability. The CASE was then used with 211 primary caregivers. Validity and reliability were evaluated, as well as the factorial structure of the instrument. This version showed good psychometric properties. It was found to have strong internal consistency and split-half reliability as well as allowing for a good replication of the original factorial structure. Additionally, several variables related to elder abuse were linked to the CASE such as depression, burden, frequency, and reactions to problem behaviors. The version developed showed sufficient validity and reliability and could be considered as a suitable instrument to assess risks of elder abuse in a Spanish-speaking context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster Purpose: A study to validate a prototype Hartmann-Shack (HS) wavefront aberrometer. Methods: The dynamic range was assessed using a calibrated model eye. It was validated against a conventional HS-aberrometer (Topcon KR1W) in 75 eyes using both instruments in random order. Additionally, intra-sessional repeatability was tested. Results: The aberrometer showed a large dynamic range of +21.0 D to −25.0 D. It was comparable to a conventional HS aberrometer for spherical-equivalent SE (MD ± 95% CI: 0.02 ± 0.49D; correlation: r = 0.995, p < 0.001), astigmatic components (J0: 0.02 ± 0.15D; r = 0.977, p < 0.001; J45: 0.03 ± 0.28; r = 0.666, p < 0.001) and HOAs RMS (0.02 ± 0.20D; r = 0.620, p < 0.001). Intra-sessional repeatability correlation was also excellent (SE = 1.000, p < 0.001; astigmatic-components J0 = 0.998, p < 0.001, J45 = 0.980, p < 0.01; HOAs RMS = 0.961, p < 0.001). Conclusions: This study confirms the validity of the prototype aberrometer. The prototype aberrometer can measure continuously to provide direct feedback of the optical status of the eye during surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the operation of the Shin-Nippon/Grand Seiko autorefractor and whether higher-order aberrations affect its peripheral refraction measurements. METHODS: Information on instrument design, together with parameters and equations used to obtain refraction, was obtained from a patent. A model eye simulating the operating principles was tested with an optical design program. Effects of induced defocus and astigmatism on the retinal image were used to calibrate the model eye to match the patent equations. Coma and trefoil were added to assess their effects on the image. Peripheral refraction of a physical model eye was measured along four visual field meridians with the Shin-Nippon/Grand Seiko autorefractor SRW-5000 and a Hartmann-Shack aberrometer, and simulated autorefractor peripheral refraction was derived using the Zernike coefficients from the aberrometer. RESULTS: In simulation, the autorefractor's square image was changed in size by defocus, into rectangles or parallelograms by astigmatism, and into irregular shapes by coma and trefoil. In the presence of 1.0 D oblique astigmatism, errors in refraction were proportional to the higher-order aberrations, with up to 0.8 D sphere and 1.5 D cylinder for ±0.6 μm of coma or trefoil coefficients with a 5-mm-diameter pupil. For the physical model eye, refraction with the aberrometer was similar in all visual field meridians, but refraction with the autorefractor changed more quickly along one oblique meridian and less quickly along the other oblique meridian than along the horizontal and vertical meridians. Simulations predicted that higher-order aberrations would affect refraction in oblique meridians, and this was supported by the experimental measurements with the physical model eye. CONCLUSIONS: The autorefractor's peripheral refraction measurements are valid for horizontal and vertical field meridians, but not for oblique field meridians. Similar instruments must be validated before being adopted outside their design scope.