91 resultados para Satisfaction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Leg length inequality (LLI) was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26) for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64). The odds ratio for limping was 2.08 (95% CI 1.55-2.80). The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28). In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81), and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44). The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21). The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21). Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all significantly associated with leg shortening, whereas walking capacity was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human behavior and psychological functioning is motivated and guided by individual goals. Motivational incongruence refers to states of insufficient goal satisfaction and is tightly related to psychological problems and even psychopathology. In the present study, individual levels of motivational incongruence were assessed with the incongruence-questionnaire (INC) in a healthy sample. In addition, multi-channel resting-state EEG was measured. Individual variations of EEG synchronization and spectral power were related to individual levels of motivational incongruence. For significant correlations, the relation to intracerebral sources of electrical brain activity was investigated with sLORETA. The results indicate that, even in a healthy sample with rather low degrees of motivational incongruence, this insufficient goal satisfaction is related to consistent changes in resting state brain activity. Upper Alpha band attenuation seems to be most indicative of increased levels of motivational incongruence. This is reflected not only in significantly reduced functional connectivity, but also in changes regarding the level of brain activation, as indicated by significant effects in the spectral power and LORETA analyses. Results are related to research investigating the upper Alpha band and are discussed in the framework of Grawe's consistency theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Family needs and expectations are often unmet in the intensive care unit (ICU), leading to dissatisfaction. This study assesses cross-cultural adaptability of an instrument evaluating family satisfaction in the ICU. MATERIALS AND METHODS: A Canadian instrument on family satisfaction was adapted for German language and central European culture and then validated for feasibility, validity, internal consistency, reliability, and sensitivity. RESULTS: Content validity of a preliminary translated version was assessed by staff, patients, and next of kin. After adaptation, content and comprehensibility were considered good. The adapted translation was then distributed to 160 family members. The return rate was 71.8%, and 94.4% of questions in returned forms were clearly answered. In comparison with a Visual Analogue Scale, construct validity was good for overall satisfaction with care (Spearman rho = 0.60) and overall satisfaction with decision making (rho = 0.65). Cronbach alpha was .95 for satisfaction with care and .87 for decision-making. Only minor differences on repeated measurements were found for interrater and intrarater reliability. There was no floor or ceiling effect. CONCLUSIONS: A cross-cultural adaptation of a questionnaire on family satisfaction in the ICU can be feasible, valid, internally consistent, reliable, and sensitive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient satisfaction represents a significant outcome criterion in the context of systemic psychotherapeutic therapy research. This study investigated parent satisfaction with a psychosocial treatment program (comprising three components: child group therapy, parents' evenings, systemic family sessions) for pediatric primary headache (diagnosed according to IHS criteria). 10 weeks after the end of the treatment program, the parents were sent a questionnaire containing open questions and ten-point numerical rating scales. The sample comprised n=48 families. The return rate was 89%. The qualitative content analysis showed a hierarchical category system consisting of 3 major categories, 7 main groups and 69 sub-categories. The parents stated that they were satisfied with (1.) the effects of the treatment program, (2.) the specific treatment techniques and the medical and psychosocial headache-related information provided, and (3.) the therapeutic relationship. The mean satisfaction for all three therapy components on the ten-point numerical rating scale was 8.1 with a standard deviation of 2.0 (child headache group: 8.5; parents' evenings: 8.2; family sessions: 7.5). The results are discussed with reference to methodological aspects: avoidance of ceiling effects and social desirability in measuring customer satisfaction, order effects of items, weighting of the significance of satisfaction levels as an outcome criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.