5 resultados para patient deterioration

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients requiring CSF shunts frequently have comorbidities that can influence water and electrolyte balances. The authors report on a case involving a ventriculoperitoneal shunt in a patient who underwent intravenous hyperhydration and withdrawal of vasopressin substitution prior to scheduled high-dose chemotherapy regimen for a metastatic suprasellar germinoma. After acute neurological deterioration, the patient underwent CT scanning that demonstrated ventriculomegaly. A shunt tap revealed no flow and negative opening pressure. Due to suspicion of proximal shunt malfunction, the comatose patient underwent immediate surgical exploration of the ventricle catheter, which was found to be patent. However, acute severe hypernatremia was diagnosed during the procedure. After correction of the electrolyte disturbances, the patient regained consciousness and made a good recovery. Although rare, the effects of acute severe hypernatremia on brain volume and ventricular size should be considered in the differential diagnosis of ventriculoperitoneal shunt failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To assess patients' perception of clean intermittent self-catheterization (CISC) for voiding dysfunction. PATIENTS AND METHODS: A total of 101 patients performing CISC because of voiding dysfunction were invited to participate in this questionnaire survey. The response rate was 91% (92/101). RESULTS: The mean time over which CISC was performed was 5 years (standard deviation (SD) +/- 6.3) and the mean frequency of CISC per day was three times (SD +/- 2). Almost 80% (72/92) of the patients perceived CISC as easy or very easy and CISC did not interfere at all or interfered a little bit with work or other regular daily activities in more than 80% (76/92). Almost 90% (80/92) reported no or minimal pain while performing CISC. This did not interfere at all or interfered a little bit with work or other regular daily activities in almost 90% (80/92). Quality of life improved considerably due to CISC in more than 60% (56/92) and 12% (11/92) complained of a deterioration. In multivariable analysis, severe pain performing CISC (odds ratio 20.9, 95% confidence interval 1.7-259.9, P = 0.018) was the only factor that predicted poor quality of life. CONCLUSIONS: The majority of patients considered CISC to be an easy and painless procedure which did not interfere with daily activities. Consequently, quality of life improved in more than 60% of the patients. Therefore, CISC does not appear to be a burden for the patient and, from a patient's perspective, can be recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In several studies of antiretroviral treatment (ART) programs for persons with human immunodeficiency virus infection, investigators have reported that there has been a higher rate of loss to follow-up (LTFU) among patients initiating ART in recent years than among patients who initiated ART during earlier time periods. This finding is frequently interpreted as reflecting deterioration of patient retention in the face of increasing patient loads. However, in this paper we demonstrate by simulation that transient gaps in follow-up could lead to bias when standard survival analysis techniques are applied. We created a simulated cohort of patients with different dates of ART initiation. Rates of ART interruption, ART resumption, and mortality were assumed to remain constant over time, but when we applied a standard definition of LTFU, the simulated probability of being classified LTFU at a particular ART duration was substantially higher in recently enrolled cohorts. This suggests that much of the apparent trend towards increased LTFU may be attributed to bias caused by transient interruptions in care. Alternative statistical techniques need to be used when analyzing predictors of LTFU-for example, using "prospective" definitions of LTFU in place of "retrospective" definitions. Similar considerations may apply when analyzing predictors of LTFU from treatment programs for other chronic diseases.