19 resultados para Unstable hemoglobins

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://www.ncbi.nlm.nih.gov/pubmed/20153849

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The etiology of shoulder pain in the overhead athlete is often difficult to determine. This study hypothesized that (1) instability can present in a purely painful form, without any apparent history of instability, but with anatomic lesions indicative of instability, termed unstable painful shoulder (UPS), and that (2) arthroscopic shoulder stabilization is effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We prospectively investigated urinary iodine concentration (UIC) in pregnant women and in female, non-pregnant controls in the canton of Berne, Switzerland, in 1992. Mean UIC of pregnant women [205 +/- 151 microg iodine/g creatinine (microg l/g Cr); no. = 153] steadily decreased from the first (236 +/- 180 microg l/g Cr; no. = 31) to the third trimester (183 +/- 111 microg l/g Cr, p < 0.0001; no. = 66) and differed significantly from that of the control group (91 +/- 37 microg l/g Cr, p < 0.0001; no. = 119). UIC increased 2.6-fold from levels indicating mild iodine deficiency in controls to the first trimester, demonstrating that high UIC during early gestation does not necessarily reflect a sufficient iodine supply to the overall population. Pregnancy is accompanied by important alterations in the regulation of thyroid function and iodine metabolism. Increased renal iodine clearance during pregnancy may explain increased UIC during early gestation, whereas increased thyroidal iodine clearance as well as the iodine shift from the maternal circulation to the growing fetal-placental unit, which both tend to lower the circulating serum levels of inorganic iodide, probably are the causes of the continuous decrease of UIC over the course of pregnancy. Mean UIC in our control group, as well as in one parallel and several consecutive investigations in the same region in the 1990s, was found to be below the actually recommended threshold, indicating a new tendency towards mild to moderate iodine deficiency. As salt is the main source of dietary iodine in Switzerland, its iodine concentration was therefore increased nationwide in 1998 for the fourth time, following increases in 1922, 1965 and 1980.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fracture patterns in bicondylar tibial plateau fractures and their impact on treatment strategy. DESIGN: Prospective data analysis with documentation of initial injury and treatment strategy, computed tomography scans, conventional x-rays, long-term evaluation of radiographs, and functional assessments. SETTING: Level 1 regional trauma center. PATIENTS: Prospective data acquisition of 14 consecutive patients (10 male and 4 female) with a bicondylar tibial plateau fracture (AO Type C). INTERVENTION: Application of a stepwise reconstruction strategy of the tibial plateau starting with the reposition and fixation of the posteromedial split fragment using a 3.5 buttress plate, followed by reposition and grafting of the lateral compartment and lateral fixation with a 3.5 plate in 90 degree to the medial fixation device. MAIN OUTCOME MEASUREMENTS: All patients were evaluated with full-length standing film, standardized x-rays, Lysholm score for functional assessment, and patient's self-appraisal. RESULTS: Most of the complex bicondylar fractures follow a regular pattern in that the medial compartment is split in a mediolateral direction with a posteromedial main fragment, combined with various amounts of multifragmental lateral compartment depression. The technique introduced allows for accurate and stable reduction and fixation of this fracture type. The final Lysholm knee score showed an average of 83.5 points (range: 64.5-92). CONCLUSIONS: Complex bicondylar tibial plateau fractures follow a regular pattern, which is not represented in existing 2-dimensional fracture classifications. A 2-incision technique starting with the reduction of the posteromedial edge results in accurate fracture reduction with low complication rates and excellent knee function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A growing body of longitudinal studies suggests that low self-esteem is a risk factor for depression. However, it is unclear whether other characteristics of self-esteem, besides its level, explain incremental or even greater variance in subsequent depression. We examined the prospective effects of self-esteem level, instability (i.e., the degree of variability in self-esteem across short periods), and contingency (i.e., the degree to which self-esteem fluctuates in response to self-relevant events) on depressive symptoms in 1 overarching model, using data from 2 longitudinal studies. In Study 1, 372 adults were assessed at 2 waves over 6 months, including 40 daily diary assessments at Wave 1. In Study 2, 235 young adults were assessed at 2 waves over 6 weeks, including about 6 daily diary assessments at each wave. Self-esteem contingency was measured by self-report and by a statistical index based on the diary data (capturing event-related fluctuations in self-esteem). In both studies self-esteem level, but not self-esteem contingency, predicted subsequent depressive symptoms. Self-esteem instability predicted subsequent depressive symptoms in Study 2 only, with a smaller effect size than self-esteem level. Also, level, instability, and contingency of self-esteem did not interact in the prediction of depressive symptoms. Moreover, the effect of self-esteem level held when controlling for neuroticism and for all other Big Five personality traits. Thus, the findings provide converging evidence for a vulnerability effect of self-esteem level, tentative evidence for a smaller vulnerability effect of self-esteem instability, and no evidence for a vulnerability effect of self-esteem contingency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study explored the effects of unstable shoe design on oxygen consumption. Methods. Oxygen consumption (VO2) and heart rate (HR) were measured in 16 individuals while barefoot, wearing unstable shoes (Masai Barefoot Technology) and wearing conventional sport shoes while standing and walking on a treadmill and for 5 individuals while walking around a 400 m track. Results. When wearing the MBT shoes, a significant (p < 0.01) increase of 9.3 ± 5.2% in VO2 was measured while standing quietly for 6 min. No differences in VO2 and HR were observed between the MBT shoes or weight-adjusted conventional shoes (to match the weight of the MBT shoes) while walking on a treadmill. However, significant increases (p < 0.01) in VO2 (4.4 ± 8.2%) and HR (3.6 ± 7.3%) were observed for the MBT shoes compared with being barefoot. No significant differences in VO2 and HR were recorded while walking around a 400 m track either with MBT shoes, weight-adjusted conventional shoes or barefoot. Nonetheless, a comparison of the MBT shoes with barefoot revealed a tendency for VO2 to be higher when wearing the MBT shoes (7.1 ± 6.5%, p < 0.1) although HR was not significantly affected. Conclusions. The unstable shoe design predominantly effects oxygen consumption while standing, most likely due to increased muscle activity of the lower extremities.